{"id":10515,"date":"2016-12-01T10:35:41","date_gmt":"2016-12-01T09:35:41","guid":{"rendered":"https:\/\/blog.wika.com\/de\/?p=10515"},"modified":"2022-04-04T06:37:12","modified_gmt":"2022-04-04T04:37:12","slug":"pt100-in-2-3-oder-4-leiter-schaltung","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/","title":{"rendered":"Pt100 in 2-, 3- oder 4-Leiter-Schaltung?"},"content":{"rendered":"<p><strong><a href=\"https:\/\/www.wika.com\/de-de\/lp_pt100_pt1000.WIKA\" rel=\"external\" target=\"_blank\">Pt100, Pt1000<\/a> und NTC sind die meist verwendeten Messelemente in <a href=\"https:\/\/www.wika.com\/de-de\/widerstandsthermometer.WIKA\" rel=\"external\" target=\"_blank\">Widerstandsthermometern<\/a>.\u00a0<\/strong><strong>Diesen Blog m\u00f6chte ich dazu nutzen, die Frage der Anschlussarten etwas genauer zu betrachten.<\/strong><\/p>\n<p>Widerstandsthermometer ver\u00e4ndern ihren elektrischen Widerstand in Abh\u00e4ngigkeit von der Temperatur. Dieser physikalische Effekt macht es erst m\u00f6glich, die Temperatur eines Prozesses mit einem Pt100 zu bestimmen. Der Widerstand wird mit einer Elektronik (z. B. <a href=\"https:\/\/www.wika.com\/de-de\/temperaturtransmitter.WIKA\" rel=\"external\" target=\"_blank\">Temperaturtransmitter<\/a>) durch Einpr\u00e4gen eines konstanten Stromes und Messen des Spannungsabfalls erfasst. Nach dem Ohmschen Gesetz (R = U\/I) sind Widerstand [R] und Spannung [U] bei konstantem Strom [I] zueinander proportional. Dabei gibt es\u00a0drei M\u00f6glichkeiten, den Pt100 an den Messumformer anzuschlie\u00dfen: In 2-, 3- oder 4-Leiterschaltung.<\/p>\n\n      <div class=\"wp-caption alignright\" style=\"max-width:396px;\"><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/de\/files\/2016\/11\/schaltungsarten_zeichnung-2leiter-388x190.jpg\" alt=\"Pt100-Messwiderstand in 2-Leiter-SchaltungPTC\" title=\"PTC\/NTC in 2-Leiter-Schaltung\" \/><p class=\"wp-caption-text\">Abb.: Pt100-Messwiderstand in 2-Leiter-Schaltung<\/p><\/div>\n    \n<h2>Pt100 in 2-Leiter-Schaltung<\/h2>\n<p>Bei einer 2-Leiter-Schaltung geht der Widerstand der Zuleitung als Fehler in die Messung ein. Als Richtwert gilt bei Kupferleitung mit Querschnitt 0,22 mm<sup>2<\/sup>: 0,162 \u03a9\/m \u2192 0,42 \u00b0C\/m bei Pt100. Bei einer Ausf\u00fchrung mit Pt1000 ist der Einfluss der Zuleitung mit 0,04 \u00b0C\/m um den Faktor 10 entsprechend des Grundwiderstandes geringer. Noch weniger macht sich dieser entsprechend des Grundwiderstandes R25 bei einem NTC-Messelement (z. B. R25 = 10k) bemerkbar. Wegen der stark abfallenden Kennlinie des NTC steigt der Einfluss bei h\u00f6heren Temperaturen jedoch \u00fcberproportional an.<\/p>\n\n      <div class=\"wp-caption alignright\" style=\"max-width:396px;\"><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/de\/files\/2016\/11\/schaltungsarten_zeichnung-3l-388x174.jpg\" alt=\"Pt100-Messwiderstand in 3-Leiter-Schaltung\" title=\"PTC\/NTC in 3-Leiter-Schaltung\" \/><p class=\"wp-caption-text\">Abb.: Pt100-Messwiderstand in 3-Leiter-Schaltung<\/p><\/div>\n    \n<h2>Pt100 in 3-Leiter-Schaltung<\/h2>\n<p>Der Einfluss des Leitungswiderstandes wird mit einer 3-Leiter-Schaltung weitestgehend kompensiert. Voraussetzung hierf\u00fcr ist, dass die Leitungswiderst\u00e4nde gleich sind, wovon bei einer 3-adrigen Anschlussleitung ausgegangen werden kann. Die maximale L\u00e4nge der Anschlussleitung h\u00e4ngt vom Leitungsquerschnitt und von den Kompensationsm\u00f6glichkeiten der Auswerteelektronik (Transmitter, Anzeige, Regler oder Prozessleitsystem) ab.\u00a0<\/p>\n\n      <div class=\"wp-caption alignright\" style=\"max-width:396px;\"><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/de\/files\/2016\/11\/schaltungsarten_zeichnung-4leiter-388x135.jpg\" alt=\"Pt100-Messwiderstand in 4-Leiter-Schaltung\" title=\"NTC\/PTC in 4-Leiter-Schaltung\" \/><p class=\"wp-caption-text\">Abb.: Pt100-Messwiderstand in 4-Leiter-Schaltung<\/p><\/div>\n    \n<h2>Pt100 in 4-Leiter-Schaltung<\/h2>\n<p>Die 4-Leiter-Schaltung eliminiert den Einfluss der Anschlussleitung auf das Messergebnis vollst\u00e4ndig, da auch eventuelle Asymmetrien im Leitungswiderstand der Anschlussleitung kompensiert werden.<\/p>\n<h2>\u00a0<\/h2>\n<h2>Alternative Ma\u00dfnahmen<\/h2>\n<p>Eine weitere M\u00f6glichkeit den Einfluss der Zuleitung wesentlich zu verringern, besteht darin, den Leitungsquerschnitt zu erh\u00f6hen. Bei einem Querschnitt von 0,5 mm<sup><span style=\"font-size: small\">2<\/span><\/sup> betr\u00e4gt der Leitungswiderstand nur noch 0,036 \u03a9\/m bzw. 0,1 \u00b0C\/m. Beide M\u00f6glichkeiten (3\/4-Leiterschaltung oder Erh\u00f6hung des Querschnittes) f\u00fchren zu h\u00f6heren Kosten der Zuleitung, die insbesondere in preissensitiven M\u00e4rkten wie im Maschinenbau problematisch sein k\u00f6nnen. Als Kompromiss zwischen Kosten und Genauigkeit bietet sich bei kleineren Leitungsl\u00e4ngen ein Pt1000-Messelement, Klasse A in 2-Leiterschaltung an.<\/p>\n<table style=\"border-collapse: collapse;width: 100%;height: 294px\">\n<tbody>\n<tr style=\"height: 49px\">\n<td style=\"width: 25%;height: 49px\"><strong>Messelement<\/strong><\/td>\n<td style=\"width: 25%;height: 49px\"><strong>Schaltungsart<\/strong><\/td>\n<td style=\"width: 25%;height: 49px\"><strong>Toleranzklasse<\/strong><\/td>\n<td style=\"width: 25%;height: 49px\"><strong>Messfehler in \u00b0C<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 49px\">\n<td style=\"width: 25%;height: 147px\" rowspan=\"4\">Pt100<\/td>\n<td style=\"width: 25%;height: 49px\">2-Leiter<\/td>\n<td style=\"width: 25%;height: 49px\">B<\/td>\n<td style=\"width: 25%;height: 49px\">5,25<\/td>\n<\/tr>\n<tr style=\"height: 49px\">\n<td style=\"width: 25%;height: 49px\">\u00a0 \u00a0 2-Leiter<\/td>\n<td style=\"width: 25%;height: 49px\">A<\/td>\n<td style=\"width: 25%;height: 49px\">4,65<\/td>\n<\/tr>\n<tr style=\"height: 49px\">\n<td style=\"width: 25%;height: 49px\">\u00a0 \u00a0 4-Leiter<\/td>\n<td style=\"width: 25%;height: 49px\">B<\/td>\n<td style=\"width: 25%;height: 49px\">1,05<\/td>\n<\/tr>\n<tr style=\"height: 49px\">\n<td style=\"width: 25%;height: 49px\">\u00a0 \u00a0 4-Leiter<\/td>\n<td style=\"width: 25%;height: 49px\">A<\/td>\n<td style=\"width: 25%;height: 49px\">0,45<\/td>\n<\/tr>\n<tr style=\"height: 49px\">\n<td style=\"width: 25%;height: 49px\" rowspan=\"4\">Pt1000<\/td>\n<td style=\"width: 25%;height: 49px\">2-Leiter<\/td>\n<td style=\"width: 25%;height: 49px\">B<\/td>\n<td style=\"width: 25%;height: 49px\">1,47<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25%\">\u00a0 \u00a0 2-Leiter<\/td>\n<td style=\"width: 25%\">A<\/td>\n<td style=\"width: 25%\">0,87<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25%\">\u00a0 \u00a0 4-Leiter<\/td>\n<td style=\"width: 25%\">B<\/td>\n<td style=\"width: 25%\">1,05<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25%\">\u00a0 \u00a0 4-Leiter<\/td>\n<td style=\"width: 25%\">A<\/td>\n<td style=\"width: 25%\">0,45<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Beispiel: Messfehler bei 150 \u00b0C, Leitungsl\u00e4nge 10 m, Leitungsquerschnitt 0,22 mm<sup>2<\/sup><\/p>\n<h2>Fazit<\/h2>\n<ul>\n<li>H\u00f6chste Messgenauigkeiten sind mit einem Pt100 nur in 4-Leiterschaltung realisierbar.<\/li>\n<li>Ein Pt1000-Messelement in Klasse A bietet auch bei einer 2-Leiterschaltung gute Messgenauigkeiten und stellt im Maschinenbau eine kosteng\u00fcnstige Alternative zur 3- bzw. 4-Leiterschaltung dar.<\/li>\n<\/ul>\n<p><strong>Hinweis<br \/>\n<\/strong>N\u00e4here Informationen zu unserem Angebot an <a href=\"https:\/\/www.wika.com\/de-de\/widerstandsthermometer.WIKA\" rel=\"external\" target=\"_blank\">Widerstandsthermometern<\/a> finden Sie auf der WIKA-Webseite. M\u00f6chten Sie einen <a href=\"https:\/\/shop.wika.com\/de-de\/widerstandsthermometer.WIKA\" rel=\"external\" target=\"_blank\">Widerstandsthermometer kaufen<\/a>? In unserem WIKA Online-Shop finden Sie eine Auswahl an Standard-Ausf\u00fchrungen.<\/p>\n<p>Informieren Sie sich weiterhin in folgendem Video \u00fcber die Unterschiede zwischen einem Pt100 und einem Pt1000 Widerstandssensor:<\/p>\n<div data-fullscreen=\"disabled\" data-mode=\"normal\" data-oembed=\"1\" data-provider=\"youtube\" data-reset-after-played id=\"arve-youtube-rzk5onlpkk8\" style=\"max-width:900px;\" class=\"arve\">\n<div class=\"arve-inner\">\n<div style=\"aspect-ratio:500\/281\" class=\"arve-embed arve-embed--has-aspect-ratio\">\n<div class=\"arve-ar\" style=\"padding-top:56.200000%\"><\/div>\n<p>\t\t\t<iframe allow=\"accelerometer &apos;none&apos;;autoplay &apos;none&apos;;bluetooth &apos;none&apos;;browsing-topics &apos;none&apos;;camera &apos;none&apos;;clipboard-read &apos;none&apos;;clipboard-write;display-capture &apos;none&apos;;encrypted-media &apos;none&apos;;gamepad &apos;none&apos;;geolocation &apos;none&apos;;gyroscope &apos;none&apos;;hid &apos;none&apos;;identity-credentials-get &apos;none&apos;;idle-detection &apos;none&apos;;keyboard-map &apos;none&apos;;local-fonts;magnetometer &apos;none&apos;;microphone &apos;none&apos;;midi &apos;none&apos;;otp-credentials &apos;none&apos;;payment &apos;none&apos;;picture-in-picture;publickey-credentials-create &apos;none&apos;;publickey-credentials-get &apos;none&apos;;screen-wake-lock &apos;none&apos;;serial &apos;none&apos;;summarizer &apos;none&apos;;sync-xhr;usb &apos;none&apos;;web-share;window-management &apos;none&apos;;xr-spatial-tracking &apos;none&apos;;\" allowfullscreen=\"\" class=\"arve-iframe fitvidsignore\" credentialless data-arve=\"arve-youtube-rzk5onlpkk8\" data-lenis-prevent=\"\" data-src-no-ap=\"https:\/\/www.youtube-nocookie.com\/embed\/RzK5onlpkK8?feature=oembed&amp;iv_load_policy=3&amp;modestbranding=1&amp;rel=0&amp;autohide=1&amp;playsinline=0&amp;autoplay=0&amp;enablejsapi=1\" frameborder=\"0\" height=\"505.8\" loading=\"lazy\" name=\"\" referrerpolicy=\"strict-origin-when-cross-origin\" sandbox=\"allow-scripts allow-same-origin allow-presentation allow-popups allow-popups-to-escape-sandbox\" scrolling=\"no\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/RzK5onlpkK8?feature=oembed&#038;iv_load_policy=3&#038;modestbranding=1&#038;rel=0&#038;autohide=1&#038;playsinline=0&#038;autoplay=0&#038;enablejsapi=1\" title=\"Wie funktioniert ein Widerstandsthermometer? | Widerstandsthermometer nach IEC 60751\" width=\"900\"><\/iframe><\/p><\/div>\n<\/p><\/div>\n<p>\t<script type=\"application\/ld+json\">{\"@context\":\"http:\\\/\\\/schema.org\\\/\",\"@id\":\"https:\\\/\\\/blog.wika.com\\\/de\\\/know-how\\\/pt100-in-2-3-oder-4-leiter-schaltung\\\/#arve-youtube-rzk5onlpkk8\",\"type\":\"VideoObject\",\"embedURL\":\"https:\\\/\\\/www.youtube-nocookie.com\\\/embed\\\/RzK5onlpkK8?feature=oembed&iv_load_policy=3&modestbranding=1&rel=0&autohide=1&playsinline=0&autoplay=0&enablejsapi=1\",\"name\":\"Wie funktioniert ein Widerstandsthermometer? | Widerstandsthermometer nach IEC 60751\",\"thumbnailUrl\":\"https:\\\/\\\/i.ytimg.com\\\/vi\\\/RzK5onlpkK8\\\/hqdefault.jpg\",\"uploadDate\":\"2019-02-21T14:30:19Z\",\"author\":\"WIKA Group\",\"description\":\"Was ist eigentlich ein Widerstandsthermometer, ein Pt100- beziehungsweise ein Pt1000-Sensor? Worin unterscheiden sich die Widerstandssensoren Pt100 und Pt1000? Diese und weitere wichtige Unterschiede erkl\\u00e4ren wir Ihnen in diesem Video \\u00fcber elektrische Thermometer.\\n\\u00a0\\nZumeist werden in industriellen Anwendungen zwei unterschiedliche Arten elektrischer Thermometer eingesetzt \\u2013 Widerstandsthermometer und Thermoelemente. Die Funktionsweise von Thermoelementen erkl\\u00e4ren wir in diesem Video:  Beim Widerstandsthermometer wird die Temperatur \\u00fcber einen ohmschen Messwiderstand ermittelt. Das \\u201ePt\\u201c in Pt100 steht f\\u00fcr das chemische Element Platin, die darauffolgende Ziffer gibt den Widerstandswert des Sensors bei null Grad Celsius an. Der am h\\u00e4ufigsten eingesetzte Pt100-Messwiderstand hat demnach einen elektrischen Widerstand von 100 \\u2126 (Ohm) bei 0 \\u00b0C. In speziellen Anwendungen kommen auch Pt1000-Temperatursensoren zum Einsatz. Bei sinkender oder steigender Temperatur ver\\u00e4ndert sich der elektrischer Widerstand. Dies erfolgt anhand einer definierten Kennlinie, welche durch internationale Normen geregelt ist. Die Temperatur l\\u00e4sst sich anhand des gemessenen Widerstands sehr pr\\u00e4zise bestimmen.\\n\\u00a0\\nGenauigkeit und Messbereich der Pt100-\\\/Pt1000-Temperaturf\\u00fchler\\nWie auch beim klassischen Zeigerthermometer (sehen Sie sich auch unser Video zum richtigen Ablesen von Thermometern an:  gibt es beim Widerstandsthermometer verschiedene Genauigkeitsklassen. Es gilt: Je genauer ein Widerstandsthermometer messen soll, umso eingeschr\\u00e4nkter ist dessen zul\\u00e4ssiger Messbereich. Ebenso muss man die Art (Bauform) des Messwiderstands beachten.\\nWird ein D\\u00fcnnschicht- oder ein drahtgewickelter Widerstand eingesetzt? Abh\\u00e4ngig von dem ausgew\\u00e4hlten Messwiderstand gibt es anhand der IEC-Norm 60751 unterschiedliche Temperaturmessbereiche. Zum Beispiel haben drahtgewickelte Widerstandsthermometer der Klasse B einen definierten Messbereich von -196 \\u00b0C bis maximal 600 \\u00b0C. Sollte dieser Bereich \\u00fcber- oder unterschritten werden, beginnen die Messwerte der Temperatursensoren zu driften, demnach messen diese nicht mehr innerhalb der definierten Genauigkeit und verf\\u00e4lschen somit das Messergebnis. Nach heutigem Stand der Technik ist diese Drift bei D\\u00fcnnschicht-Sensoren st\\u00e4rker als bei drahtgewickelten Sensoren.\\n\\u00a0\\n\\u00a0\\nWeitere Informationen \\u00fcber Pt100- und Pt1000-Sensoren finden Sie auf unserer Webseite: \\n\\u00a0\\nBei WIKA k\\u00f6nnen Sie die g\\u00e4ngigsten Widerstandsthermometer direkt im Online-Shop konfigurieren und bestellen: \\n\\u00a0\\nEine \\u00dcbersicht aller Widerstandsthermometer finden Sie auf unserer Webseite:  \\n\\nM\\u00f6chten Sie mehr \\u00fcber Widerstandsthermometer erfahren? \\nDann lesen Sie unseren Blog ( oder die technische Information zum Thema \\u201eEinsatzgrenzen und Genauigkeiten von Platin-Widerstandsthermometern nach DIN EN IEC 60751\\u201c (\\n\\n-------------------------------------------------------------------------------\\n\\nFolgen Sie uns auf unseren Social-Media-Kan\\u00e4len:\\n\\ud83d\\udcfa YouTube: \\n\\u2705 LinkedIn: \\n\\n\\u25ac Inhalt des Videos \\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\u25ac \\n0:00 Intro\\n0:12 Funktionsprinzip eines Widerstandsthermometers\\n0:46 Platin-Widerstandsthermometer: Messbereich\\n1:18 RTD: Genauigkeit und Standardmessbereich\\n1:54 Pt100 Temperatursensor: ein industrieller Standard\\n2:06 Pt1000 und Pt25: f\\u00fcr besondere F\\u00e4lle\"}<\/script><\/p>\n<\/div>\n<p><strong>Lesen Sie auch unseren Beitrag<\/strong><br \/>\n<a href=\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-klasse-b-oder-f-03-was-sagt-die-iec-60751\/\" target=\"_blank\" rel=\"noopener noreferrer\">Pt100 in Klasse B oder F 0,3 &#8211; Was sagt die IEC 60751?<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Pt100, Pt1000 und NTC sind die meist verwendeten Messelemente in Widerstandsthermometern.\u00a0Diesen Blog m\u00f6chte ich dazu nutzen, die Frage der Anschlussarten etwas genauer zu betrachten. Widerstandsthermometer ver\u00e4ndern ihren elektrischen Widerstand in Abh\u00e4ngigkeit von der Temperatur. Dieser physikalische Effekt macht es erst m\u00f6glich, die Temperatur eines Prozesses mit einem Pt100 zu bestimmen. Der Widerstand wird mit einer [&hellip;]<\/p>\n","protected":false},"author":73,"featured_media":10545,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[393],"tags":[555,553,554,556,291,557],"class_list":["post-10515","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-know-how","tag-ntc","tag-pt100","tag-pt1000","tag-temperatur","tag-transmitter","tag-widerstandsthermometer"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Pt100-Messwiderstand in 2-, 3-, 4-Leiter-Schaltung - WIKA-Blog<\/title>\n<meta name=\"description\" content=\"Wie k\u00f6nnen Messfehler bei Widerstandsthermometern mit einem Pt100- \/Pt1000- oder NTC-Messelement vermieden werden?- Richtige Anschlussart finden.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Pt100-Messwiderstand in 2-, 3-, 4-Leiter-Schaltung - WIKA-Blog\" \/>\n<meta property=\"og:description\" content=\"Wie k\u00f6nnen Messfehler bei Widerstandsthermometern mit einem Pt100- \/Pt1000- oder NTC-Messelement vermieden werden?- Richtige Anschlussart finden.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA-Blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/de\/files\/2016\/10\/schaltungsarten_zeichnung_beitragsbild.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"839\" \/>\n\t<meta property=\"og:image:height\" content=\"376\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Roland Sachs\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Roland Sachs\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"4\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/\"},\"author\":{\"name\":\"Roland Sachs\",\"@id\":\"https:\/\/blog.wika.com\/de\/#\/schema\/person\/288dfcce0aea635846154c019d4ca8cc\"},\"headline\":\"Pt100 in 2-, 3- oder 4-Leiter-Schaltung?\",\"datePublished\":\"2016-12-01T09:35:41+00:00\",\"dateModified\":\"2022-04-04T04:37:12+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/\"},\"wordCount\":547,\"commentCount\":1,\"publisher\":{\"@id\":\"https:\/\/blog.wika.com\/de\/#organization\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/de\/files\/2016\/10\/schaltungsarten_zeichnung_beitragsbild.jpg\",\"keywords\":[\"NTC\",\"Pt100\",\"Pt1000\",\"Temperatur\",\"Transmitter\",\"Widerstandsthermometer\"],\"articleSection\":[\"Know-how\"],\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/\",\"url\":\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/\",\"name\":\"Pt100-Messwiderstand in 2-, 3-, 4-Leiter-Schaltung - WIKA-Blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/de\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/de\/files\/2016\/10\/schaltungsarten_zeichnung_beitragsbild.jpg\",\"datePublished\":\"2016-12-01T09:35:41+00:00\",\"dateModified\":\"2022-04-04T04:37:12+00:00\",\"description\":\"Wie k\u00f6nnen Messfehler bei Widerstandsthermometern mit einem Pt100- \/Pt1000- oder NTC-Messelement vermieden werden?- Richtige Anschlussart finden.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/de\/files\/2016\/10\/schaltungsarten_zeichnung_beitragsbild.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/de\/files\/2016\/10\/schaltungsarten_zeichnung_beitragsbild.jpg\",\"width\":839,\"height\":376,\"caption\":\"Schemazeichnung Pt100 in 2-, 3- oder 4-Leiter-Schaltung\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/blog.wika.com\/de\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pt100 in 2-, 3- oder 4-Leiter-Schaltung?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/de\/#website\",\"url\":\"https:\/\/blog.wika.com\/de\/\",\"name\":\"WIKA-Blog\",\"description\":\"Unser deutschsprachiger Blog bietet viele interessante Beitr\u00e4ge rund um die Druck-, Temperatur-, F\u00fcllstands-, Kraft-, Durchflussmesstechnik und Kalibriertechnik sowie Einblicke in die Welt der WIKA Unternehmensgruppe.\",\"publisher\":{\"@id\":\"https:\/\/blog.wika.com\/de\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/de\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/blog.wika.com\/de\/#organization\",\"name\":\"WIKA Alexander Wiegand SE & Co. KG\",\"url\":\"https:\/\/blog.wika.com\/de\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/blog.wika.com\/de\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/blog.wika.com\/de\/files\/2022\/11\/logo_wika_rgb_blue_5cm.png\",\"contentUrl\":\"https:\/\/blog.wika.com\/de\/files\/2022\/11\/logo_wika_rgb_blue_5cm.png\",\"width\":572,\"height\":195,\"caption\":\"WIKA Alexander Wiegand SE & Co. KG\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/de\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/de.linkedin.com\/company\/wikagroup\",\"https:\/\/www.youtube.com\/user\/WIKAGroup\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/de\/#\/schema\/person\/288dfcce0aea635846154c019d4ca8cc\",\"name\":\"Roland Sachs\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/blog.wika.com\/de\/files\/2022\/11\/sachsroland_wiw0608-5227-10x15-300dpi-120x120.jpg\",\"url\":\"https:\/\/blog.wika.com\/de\/files\/2022\/11\/sachsroland_wiw0608-5227-10x15-300dpi-120x120.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/de\/files\/2022\/11\/sachsroland_wiw0608-5227-10x15-300dpi-120x120.jpg\",\"caption\":\"Roland Sachs\"},\"description\":\"I have almost 30 years of professional experience in the most diverse fields of temperature measurement. Since 2008 I have been working in the product management for Industrial Gauges and I look forward to sharing my comprehensive knowledge with you in this blog.\",\"url\":\"https:\/\/blog.wika.com\/de\/author\/sachsr\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Pt100-Messwiderstand in 2-, 3-, 4-Leiter-Schaltung - WIKA-Blog","description":"Wie k\u00f6nnen Messfehler bei Widerstandsthermometern mit einem Pt100- \/Pt1000- oder NTC-Messelement vermieden werden?- Richtige Anschlussart finden.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/","og_locale":"de_DE","og_type":"article","og_title":"Pt100-Messwiderstand in 2-, 3-, 4-Leiter-Schaltung - WIKA-Blog","og_description":"Wie k\u00f6nnen Messfehler bei Widerstandsthermometern mit einem Pt100- \/Pt1000- oder NTC-Messelement vermieden werden?- Richtige Anschlussart finden.","og_url":"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/","og_site_name":"WIKA-Blog","og_image":[{"width":839,"height":376,"url":"https:\/\/blog.wika.com\/de\/files\/2016\/10\/schaltungsarten_zeichnung_beitragsbild.jpg","type":"image\/jpeg"}],"author":"Roland Sachs","twitter_misc":{"Verfasst von":"Roland Sachs","Gesch\u00e4tzte Lesezeit":"4\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/"},"author":{"name":"Roland Sachs","@id":"https:\/\/blog.wika.com\/de\/#\/schema\/person\/288dfcce0aea635846154c019d4ca8cc"},"headline":"Pt100 in 2-, 3- oder 4-Leiter-Schaltung?","datePublished":"2016-12-01T09:35:41+00:00","dateModified":"2022-04-04T04:37:12+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/"},"wordCount":547,"commentCount":1,"publisher":{"@id":"https:\/\/blog.wika.com\/de\/#organization"},"image":{"@id":"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/de\/files\/2016\/10\/schaltungsarten_zeichnung_beitragsbild.jpg","keywords":["NTC","Pt100","Pt1000","Temperatur","Transmitter","Widerstandsthermometer"],"articleSection":["Know-how"],"inLanguage":"de","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/","url":"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/","name":"Pt100-Messwiderstand in 2-, 3-, 4-Leiter-Schaltung - WIKA-Blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/de\/files\/2016\/10\/schaltungsarten_zeichnung_beitragsbild.jpg","datePublished":"2016-12-01T09:35:41+00:00","dateModified":"2022-04-04T04:37:12+00:00","description":"Wie k\u00f6nnen Messfehler bei Widerstandsthermometern mit einem Pt100- \/Pt1000- oder NTC-Messelement vermieden werden?- Richtige Anschlussart finden.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#primaryimage","url":"https:\/\/blog.wika.com\/de\/files\/2016\/10\/schaltungsarten_zeichnung_beitragsbild.jpg","contentUrl":"https:\/\/blog.wika.com\/de\/files\/2016\/10\/schaltungsarten_zeichnung_beitragsbild.jpg","width":839,"height":376,"caption":"Schemazeichnung Pt100 in 2-, 3- oder 4-Leiter-Schaltung"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/de\/know-how\/pt100-in-2-3-oder-4-leiter-schaltung\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/blog.wika.com\/de\/"},{"@type":"ListItem","position":2,"name":"Pt100 in 2-, 3- oder 4-Leiter-Schaltung?"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/de\/#website","url":"https:\/\/blog.wika.com\/de\/","name":"WIKA-Blog","description":"Unser deutschsprachiger Blog bietet viele interessante Beitr\u00e4ge rund um die Druck-, Temperatur-, F\u00fcllstands-, Kraft-, Durchflussmesstechnik und Kalibriertechnik sowie Einblicke in die Welt der WIKA Unternehmensgruppe.","publisher":{"@id":"https:\/\/blog.wika.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/blog.wika.com\/de\/#organization","name":"WIKA Alexander Wiegand SE & Co. KG","url":"https:\/\/blog.wika.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/blog.wika.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/blog.wika.com\/de\/files\/2022\/11\/logo_wika_rgb_blue_5cm.png","contentUrl":"https:\/\/blog.wika.com\/de\/files\/2022\/11\/logo_wika_rgb_blue_5cm.png","width":572,"height":195,"caption":"WIKA Alexander Wiegand SE & Co. KG"},"image":{"@id":"https:\/\/blog.wika.com\/de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/de.linkedin.com\/company\/wikagroup","https:\/\/www.youtube.com\/user\/WIKAGroup"]},{"@type":"Person","@id":"https:\/\/blog.wika.com\/de\/#\/schema\/person\/288dfcce0aea635846154c019d4ca8cc","name":"Roland Sachs","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/blog.wika.com\/de\/files\/2022\/11\/sachsroland_wiw0608-5227-10x15-300dpi-120x120.jpg","url":"https:\/\/blog.wika.com\/de\/files\/2022\/11\/sachsroland_wiw0608-5227-10x15-300dpi-120x120.jpg","contentUrl":"https:\/\/blog.wika.com\/de\/files\/2022\/11\/sachsroland_wiw0608-5227-10x15-300dpi-120x120.jpg","caption":"Roland Sachs"},"description":"I have almost 30 years of professional experience in the most diverse fields of temperature measurement. Since 2008 I have been working in the product management for Industrial Gauges and I look forward to sharing my comprehensive knowledge with you in this blog.","url":"https:\/\/blog.wika.com\/de\/author\/sachsr\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/de\/wp-json\/wp\/v2\/posts\/10515","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/de\/wp-json\/wp\/v2\/users\/73"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/de\/wp-json\/wp\/v2\/comments?post=10515"}],"version-history":[{"count":54,"href":"https:\/\/blog.wika.com\/de\/wp-json\/wp\/v2\/posts\/10515\/revisions"}],"predecessor-version":[{"id":21002,"href":"https:\/\/blog.wika.com\/de\/wp-json\/wp\/v2\/posts\/10515\/revisions\/21002"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/de\/wp-json\/wp\/v2\/media\/10545"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/de\/wp-json\/wp\/v2\/media?parent=10515"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/de\/wp-json\/wp\/v2\/categories?post=10515"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/de\/wp-json\/wp\/v2\/tags?post=10515"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}