{"id":12826,"date":"2022-03-15T08:12:08","date_gmt":"2022-03-15T07:12:08","guid":{"rendered":"https:\/\/blog.wika.com\/en\/?p=12826"},"modified":"2025-09-22T10:12:41","modified_gmt":"2025-09-22T08:12:41","slug":"switch-points-in-vacuum-ranges-how-are-they-set","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/","title":{"rendered":"Switch points in vacuum ranges: How are they set?"},"content":{"rendered":"<p><strong>Setting the switch points of an electronic pressure switch for an application in the vacuum range is not a self-explanatory task. The following article therefore explains what needs to be taken into account with this setting. It involves a pressure switch with a hysteresis function. Instruments with this configuration are most frequently installed in industrial applications.<\/strong><\/p>\n<p>Electronic pressure switches, such as the WIKA models PSD-4 or the A-1200 pressure sensor with IO-Link, operate as \u201cnormally closed\u201d or \u201cnormally open\u201d, depending on the task. The following graphics illustrate both switching functions with the respective switch and reset points:<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-12846 size-ArticleHalf\" src=\"https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-closed_en-388x231.png\" alt=\"\" width=\"388\" height=\"231\" srcset=\"https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-closed_en-388x231.png 388w, https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-closed_en-252x150.png 252w, https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-closed_en-768x457.png 768w, https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-closed_en.png 840w\" sizes=\"auto, (max-width: 388px) 100vw, 388px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-12848 size-ArticleHalf\" style=\"font-weight: bold;font-size: 1rem\" src=\"https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-open_en-388x231.png\" alt=\"\" width=\"388\" height=\"231\" srcset=\"https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-open_en-388x231.png 388w, https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-open_en-252x150.png 252w, https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-open_en-768x457.png 768w, https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-open_en.png 840w\" sizes=\"auto, (max-width: 388px) 100vw, 388px\" \/><\/figure>\n<p>&nbsp;<\/p>\n<p>In principle, the following applies: The switch point (SP) is greater than the reset point (RP) and the start of measuring range (MRS) is always smaller than the end of measuring range (MRE). This rule can be easily understood with settings for ambient air pressures.<\/p>\n<h2>Example: Control of a vacuum pump<\/h2>\n<p>On the other hand, setting the switch points in the vacuum range and thus, ultimately, the switching function, requires more attention. To illustrate this, let&#8217;s take the control of a vacuum pump, for example, which must maintain a vacuum between -0.7 bar and -0.5 bar. For the task described, we select a pressure switch with a measuring range of -1 &#8230; 0 bar.<\/p>\n<p>The start of measuring range (MRS) is therefore -1 bar, the end of measuring range (MRE) 0 bar. This means: At 0 bar (= start of operation) the switch should be closed, in order to switch on the vacuum pump. If the pressure drops to -0.7 bar, the switch must open and stop the pump. As soon as the pressure reaches the upper limit value of -0.5 bar, the pump should once again start and run until the pressure has again dropped to -0.7 bar.<\/p>\n<p>ow must the switch points be set within this vacuum range? Let&#8217;s take the two pictures and translate MRS and MRE:<\/p>\n<p><strong><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-12846 size-ArticleHalf\" src=\"https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-closed_en-388x231.png\" alt=\"\" width=\"388\" height=\"231\" srcset=\"https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-closed_en-388x231.png 388w, https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-closed_en-252x150.png 252w, https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-closed_en-768x457.png 768w, https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-closed_en.png 840w\" sizes=\"auto, (max-width: 388px) 100vw, 388px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-12848 size-ArticleHalf\" src=\"https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-open_en-388x231.png\" alt=\"\" width=\"388\" height=\"231\" srcset=\"https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-open_en-388x231.png 388w, https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-open_en-252x150.png 252w, https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-open_en-768x457.png 768w, https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-open_en.png 840w\" sizes=\"auto, (max-width: 388px) 100vw, 388px\" \/><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>Here it is clear that the \u201cnormally open\u201d function must be selected, otherwise the pump would not switch on. After entering the switch points, the schematic is obtained, which shows how the pressure switch functions in accordance with the example:<\/p>\n<p><strong><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/en\/files\/2022\/03\/schaltfunktion_normally-open_barwerte_en-388x231.png\" \/><\/strong><\/p>\n<p><strong>Note<\/strong><br \/>\nInformation about WIKA&#8217;s electronic pressure switches can be found on the <a href=\"https:\/\/www.wika.com\/en-en\/pressure_switches.WIKA\" rel=\"external\" target=\"_blank\">WIKA website<\/a>. Would you like to buy pressure switches? In our <a href=\"https:\/\/www.wika.com\/en-en\/pressure_switches.WIKA\" rel=\"external\" target=\"_blank\">WIKA online-shop<\/a> you will find some of our standard designs. If you have any questions, your <a href=\"https:\/\/www.wika.com\/en-en\/contact.WIKA\" rel=\"external\" target=\"_blank\">contact<\/a> will gladly help you.<\/p>\n<p><strong>Also read our posts<\/strong><br \/>\n<a href=\"https:\/\/blog.wika.com\/en\/knowhow\/switching-function-hysteresis-pressure-switch\/\">What is meant by the switching function \u201chysteresis\u201d with electronic pressure switches?<\/a><br \/>\n<a href=\"https:\/\/blog.wika.com\/en\/knowhow\/difference-switching-functions-hysteresis-window-pressure-switches\/\">What is the difference between the switching functions \u201chysteresis\u201d and \u201cwindow\u201d in pressure switches?<\/a><br \/>\n<a href=\"https:\/\/blog.wika.com\/en\/knowhow\/what-is-meant-by-the-normally-open-switching-function-with-pressure-switches\/\">What is meant by the \u201cnormally open\u201d switching function with pressure switches?<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Setting the switch points of an electronic pressure switch for an application in the vacuum range is not a self-explanatory task. The following article therefore explains what needs to be taken into account with this setting. It involves a pressure switch with a hysteresis function. Instruments with this configuration are most frequently installed in industrial [&hellip;]<\/p>\n","protected":false},"author":298,"featured_media":12835,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5],"tags":[266,563,79,210],"class_list":["post-12826","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowhow","tag-measuring-range","tag-pressure","tag-pressure-switch","tag-switching-fuction"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Switch points in vacuum ranges: How are they set? - WIKA blog<\/title>\n<meta name=\"description\" content=\"Setting the switch points for a vacuum range on an electronic pressure switch is not a self-explanatory task.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Switch points in vacuum ranges: How are they set? - WIKA blog\" \/>\n<meta property=\"og:description\" content=\"Setting the switch points for a vacuum range on an electronic pressure switch is not a self-explanatory task.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/en\/files\/2022\/03\/beitragsbild_ds_vakuum_eng.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Haydar Kartal\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Haydar Kartal\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/\"},\"author\":{\"name\":\"Haydar Kartal\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/e6ab21fb6d8886155ac1eb2140c94107\"},\"headline\":\"Switch points in vacuum ranges: How are they set?\",\"datePublished\":\"2022-03-15T07:12:08+00:00\",\"dateModified\":\"2025-09-22T08:12:41+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/\"},\"wordCount\":452,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2022\/03\/beitragsbild_ds_vakuum_eng.jpg\",\"keywords\":[\"Measuring range\",\"Pressure\",\"Pressure switch\",\"Switching function\"],\"articleSection\":[\"Know-how\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/\",\"url\":\"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/\",\"name\":\"Switch points in vacuum ranges: How are they set? - WIKA blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2022\/03\/beitragsbild_ds_vakuum_eng.jpg\",\"datePublished\":\"2022-03-15T07:12:08+00:00\",\"dateModified\":\"2025-09-22T08:12:41+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/e6ab21fb6d8886155ac1eb2140c94107\"},\"description\":\"Setting the switch points for a vacuum range on an electronic pressure switch is not a self-explanatory task.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2022\/03\/beitragsbild_ds_vakuum_eng.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2022\/03\/beitragsbild_ds_vakuum_eng.jpg\",\"width\":838,\"height\":471,\"caption\":\"Switching function normally open for a vacuum range\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.wika.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Switch points in vacuum ranges: How are they set?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/en\/#website\",\"url\":\"https:\/\/blog.wika.com\/en\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/e6ab21fb6d8886155ac1eb2140c94107\",\"name\":\"Haydar Kartal\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png\",\"caption\":\"Haydar Kartal\"},\"url\":\"https:\/\/blog.wika.com\/en\/author\/kartah\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Switch points in vacuum ranges: How are they set? - WIKA blog","description":"Setting the switch points for a vacuum range on an electronic pressure switch is not a self-explanatory task.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/","og_locale":"en_GB","og_type":"article","og_title":"Switch points in vacuum ranges: How are they set? - WIKA blog","og_description":"Setting the switch points for a vacuum range on an electronic pressure switch is not a self-explanatory task.","og_url":"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/","og_site_name":"WIKA blog","og_image":[{"width":838,"height":471,"url":"https:\/\/blog.wika.com\/en\/files\/2022\/03\/beitragsbild_ds_vakuum_eng.jpg","type":"image\/jpeg"}],"author":"Haydar Kartal","twitter_misc":{"Written by":"Haydar Kartal","Estimated reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/"},"author":{"name":"Haydar Kartal","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/e6ab21fb6d8886155ac1eb2140c94107"},"headline":"Switch points in vacuum ranges: How are they set?","datePublished":"2022-03-15T07:12:08+00:00","dateModified":"2025-09-22T08:12:41+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/"},"wordCount":452,"image":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2022\/03\/beitragsbild_ds_vakuum_eng.jpg","keywords":["Measuring range","Pressure","Pressure switch","Switching function"],"articleSection":["Know-how"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/","url":"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/","name":"Switch points in vacuum ranges: How are they set? - WIKA blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2022\/03\/beitragsbild_ds_vakuum_eng.jpg","datePublished":"2022-03-15T07:12:08+00:00","dateModified":"2025-09-22T08:12:41+00:00","author":{"@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/e6ab21fb6d8886155ac1eb2140c94107"},"description":"Setting the switch points for a vacuum range on an electronic pressure switch is not a self-explanatory task.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/#primaryimage","url":"https:\/\/blog.wika.com\/en\/files\/2022\/03\/beitragsbild_ds_vakuum_eng.jpg","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2022\/03\/beitragsbild_ds_vakuum_eng.jpg","width":838,"height":471,"caption":"Switching function normally open for a vacuum range"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/en\/knowhow\/switch-points-in-vacuum-ranges-how-are-they-set\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/en\/"},{"@type":"ListItem","position":2,"name":"Switch points in vacuum ranges: How are they set?"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/en\/#website","url":"https:\/\/blog.wika.com\/en\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/e6ab21fb6d8886155ac1eb2140c94107","name":"Haydar Kartal","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png","url":"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png","caption":"Haydar Kartal"},"url":"https:\/\/blog.wika.com\/en\/author\/kartah\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/12826","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/users\/298"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/comments?post=12826"}],"version-history":[{"count":16,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/12826\/revisions"}],"predecessor-version":[{"id":52106,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/12826\/revisions\/52106"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media\/12835"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media?parent=12826"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/categories?post=12826"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/tags?post=12826"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}