{"id":12952,"date":"2022-05-20T07:09:17","date_gmt":"2022-05-20T05:09:17","guid":{"rendered":"https:\/\/blog.wika.com\/en\/?p=12952"},"modified":"2022-06-24T10:06:24","modified_gmt":"2022-06-24T08:06:24","slug":"lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/","title":{"rendered":"Lasting accuracy for diaphragm seal systems for vacuum process"},"content":{"rendered":"<p><strong>A diaphragm seal system in a vacuum process must master a major challenge \u2013 it must deliver a reliable measuring result, even when the pressure drops and the temperature rises at the same time. The example of a chemical company producing phthalic anhydride (PA) shows that it is by no means self-evident that this requirement can be met on a consistent basis.<\/strong><\/p>\n<p>PA is primarily used as a plasticiser for plastics. However, it is also used in the production of synthetic resins and dyes. The plant operator obtains this compound via the catalytic oxidation of o-xylene in the gas phase, followed by a vacuum distillation process.<\/p>\n<h2>Critical phase for pressure measurement<\/h2>\n<p>In this process, the critical phase for pressure measurement occurs in the distillation column. There, the process temperature can rise to more than 230 \u00b0C while the pressure drops to 100 mbar abs. With such a contrary action, the conventional installed measurement technology reaches its performance limit relatively quickly, which the aforementioned manufacturer was forced to find out \u2013 all instrumentation showed a measurement deviation outside the defined tolerance after only fourteen days.<\/p>\n<h2>Diaphragm seal system adapted in all elements to the vacuum process<\/h2>\n\n      <div class=\"wp-caption alignright\" style=\"max-width:396px;\"><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/en\/files\/2022\/04\/20220315_textbild_ds_vakuumprozess_schmuckbild-388x249.png\" alt=\"Diaphragm seal system for vacuum process\" \/><p class=\"wp-caption-text\">The diaphragm seal system is tailored exactly to the conditions of the vacuum process and tested under application conditions.<\/p><\/div>\n    \n<p>Consequently, the company approached WIKA with the request for a measuring solution that would also fulfil its task with the required accuracy in the long term under the conditions described. WIKA then drew on its in-depth expertise to design a diaphragm seal system for the vacuum process, consisting of a process transmitter (model IPT-20), a flange-type diaphragm seal with flush diaphragm (model 990.27) and a capillary.<\/p>\n<p>All elements of this measuring system were selected specifically for the application. Silicone oil KN32 was therefore selected as the fill fluid for pressure transmission. The cleaning and conditioning of the diaphragm seal, the capillary, the connection pieces and also the automated filling process were also matched to each other exactly. With sensitive limit ranges, even one drop of liquid too much or too little can destabilise the volume balance of the diaphragm seal system and thus impair its function. As a result, correct measurement would no longer be guaranteed.<\/p>\n<h2>Test under application conditions<\/h2>\n<p>After cleaning, all parts of the diaphragm seal system were first fully welded into a single unit as usual, followed by the filling and adjustment of the system. Before delivery, however, there was another crucial step \u2013 in its laboratory, WIKA simulated a vacuum process for the diaphragm seal system in accordance with the customer&#8217;s conditions and subjected it to a thermal ageing process. This test confirmed the process suitability of the measuring system.<\/p>\n<p><strong>Note<\/strong><br \/>\nFurther information on the WIKA diaphragm seal systems can be found on the <a href=\"https:\/\/www.wika.com\/en-en\/diaphragm_seal_systems.WIKA\" rel=\"external\" target=\"_blank\">WIKA website<\/a>. If you have any questions, your <a href=\"https:\/\/www.wika.com\/en-en\/contact.WIKA\" rel=\"external\" target=\"_blank\">contact<\/a> will gladly help you.<\/p>\n<p><strong>Also read our posts<\/strong><br \/>\n<a href=\"https:\/\/blog.wika.com\/en\/applications\/diaphragm-seals-for-stable-flow-measurement-in-deep-seas\/\">Diaphragm seals for stable flow measurement in deep seas<\/a><br \/>\n<a href=\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/how-diaphragm-seals-working\/\">How do diaphragm seals work?<\/a><\/p>\n<p>Watch the following video to learn more about the functionality, application areas and advantages of diaphragm seals:<\/p>\n<div data-fullscreen=\"disabled\" data-mode=\"normal\" data-oembed=\"1\" data-provider=\"youtube\" data-reset-after-played id=\"arve-youtube-5scb2necfos\" style=\"max-width:900px;\" class=\"arve\">\n<div class=\"arve-inner\">\n<div style=\"aspect-ratio:500\/281\" class=\"arve-embed arve-embed--has-aspect-ratio\">\n<div class=\"arve-ar\" style=\"padding-top:56.200000%\"><\/div>\n<p>\t\t\t<iframe allow=\"accelerometer &apos;none&apos;;autoplay &apos;none&apos;;bluetooth &apos;none&apos;;browsing-topics &apos;none&apos;;camera &apos;none&apos;;clipboard-read &apos;none&apos;;clipboard-write;display-capture &apos;none&apos;;encrypted-media &apos;none&apos;;gamepad &apos;none&apos;;geolocation &apos;none&apos;;gyroscope &apos;none&apos;;hid &apos;none&apos;;identity-credentials-get &apos;none&apos;;idle-detection &apos;none&apos;;keyboard-map &apos;none&apos;;local-fonts;magnetometer &apos;none&apos;;microphone &apos;none&apos;;midi &apos;none&apos;;otp-credentials &apos;none&apos;;payment &apos;none&apos;;picture-in-picture;publickey-credentials-create &apos;none&apos;;publickey-credentials-get &apos;none&apos;;screen-wake-lock &apos;none&apos;;serial &apos;none&apos;;summarizer &apos;none&apos;;sync-xhr;usb &apos;none&apos;;web-share;window-management &apos;none&apos;;xr-spatial-tracking &apos;none&apos;;\" allowfullscreen=\"\" class=\"arve-iframe fitvidsignore\" credentialless data-arve=\"arve-youtube-5scb2necfos\" data-lenis-prevent=\"\" data-src-no-ap=\"https:\/\/www.youtube-nocookie.com\/embed\/5ScB2nEcfOs?feature=oembed&amp;iv_load_policy=3&amp;modestbranding=1&amp;rel=0&amp;autohide=1&amp;playsinline=0&amp;autoplay=0&amp;enablejsapi=1\" frameborder=\"0\" height=\"505.8\" loading=\"lazy\" name=\"\" referrerpolicy=\"strict-origin-when-cross-origin\" sandbox=\"allow-scripts allow-same-origin allow-presentation allow-popups allow-popups-to-escape-sandbox\" scrolling=\"no\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/5ScB2nEcfOs?feature=oembed&#038;iv_load_policy=3&#038;modestbranding=1&#038;rel=0&#038;autohide=1&#038;playsinline=0&#038;autoplay=0&#038;enablejsapi=1\" title=\"How do diaphragm seals work? | Areas of application and advantages in pressure measurement\" width=\"900\"><\/iframe><\/p><\/div>\n<\/p><\/div>\n<p>\t<script type=\"application\/ld+json\">{\"@context\":\"http:\\\/\\\/schema.org\\\/\",\"@id\":\"https:\\\/\\\/blog.wika.com\\\/en\\\/applications\\\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\\\/#arve-youtube-5scb2necfos\",\"type\":\"VideoObject\",\"embedURL\":\"https:\\\/\\\/www.youtube-nocookie.com\\\/embed\\\/5ScB2nEcfOs?feature=oembed&iv_load_policy=3&modestbranding=1&rel=0&autohide=1&playsinline=0&autoplay=0&enablejsapi=1\",\"name\":\"How do diaphragm seals work? | Areas of application and advantages in pressure measurement\",\"thumbnailUrl\":\"https:\\\/\\\/i.ytimg.com\\\/vi\\\/5ScB2nEcfOs\\\/hqdefault.jpg\",\"uploadDate\":\"2018-11-27T11:09:53Z\",\"author\":\"WIKA Group\",\"description\":\"WIKA diaphragm seals can be connected to almost all pressure gauges, process transmitters, pressure switches or pressure sensors. But why are diaphragm seals needed in the first place?\\n\\nBasically, diaphragm seals are used with all pressure measurements where direct contact between the measuring instrument and the medium should be avoided. Furthermore, diaphragm seals ( are also used if the measuring point is located in a hard-to-reach place where the measuring instrument cannot be mounted or read. In both cases, the pressure acting is transmitted to the measuring instrument via a system fill fluid within the case of the diaphragm seal.\\n\\nThe seals\\u2019 diaphragms can be made of different materials such as stainless steels, Hastelloy, Monel or tantalum. Furthermore, coatings with ECTFE, PFA or gold are also possible. Diaphragm seals, coated with our patented Wikaramic\\u00ae, are highly resistant to wear and can thus also withstand abrasive media.\\n\\nThe optimal diaphragm seal designs, materials, system fill fluids and accessories are available for each application. The configuration of the combination of pressure measuring instruments and diaphragm seals depends, among other things, on the application conditions in which the diaphragm seal system must work.\\nFor the diaphragm seals, test certificates and approvals for special applications can be supplied.\\n\\nNo matter how complex the requirements seem, diaphragm seals can be flexibly adapted to the respective measuring conditions. WIKA will gladly advise you on the selection of the diaphragm seal suitable for your application.\\n\\n\\ud83d\\uded2 In our online shop we also offer complete diaphragm seal systems with pressure gauges, pressure switches or pressure sensors: \\n\\n\\ud83d\\udcd6 In our blog post \\u201cHow do diaphragm seals work?\\u201d we provide you with further insights into the assembly of a diaphragm seal: \\n\\n_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ \\n\\nFollow us on our social media channels:\\n\\ud83d\\udcfa YouTube: \\n\\ud83c\\udfaf LinkedIn:\"}<\/script><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>A diaphragm seal system in a vacuum process must master a major challenge \u2013 it must deliver a reliable measuring result, even when the pressure drops and the temperature rises at the same time. The example of a chemical company producing phthalic anhydride (PA) shows that it is by no means self-evident that this requirement [&hellip;]<\/p>\n","protected":false},"author":134,"featured_media":12955,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[232],"tags":[286,285,563,566],"class_list":["post-12952","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications","tag-chemical","tag-diaphragm-seals","tag-pressure","tag-processtransmitter"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Lasting accuracy for diaphragm seal systems for vacuum process - WIKA blog<\/title>\n<meta name=\"description\" content=\"Falling pressure, rising temperature: A diaphragm seal system in the vacuum process must overcome a major challenge.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Lasting accuracy for diaphragm seal systems for vacuum process - WIKA blog\" \/>\n<meta property=\"og:description\" content=\"Falling pressure, rising temperature: A diaphragm seal system in the vacuum process must overcome a major challenge.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/en\/files\/2022\/04\/beitragsbild_ds_vakuumprozess.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Jing Lyu\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Jing Lyu\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/\"},\"author\":{\"name\":\"Jing Lyu\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/63ca8fb13617fef6c5b5e2985e493f80\"},\"headline\":\"Lasting accuracy for diaphragm seal systems for vacuum process\",\"datePublished\":\"2022-05-20T05:09:17+00:00\",\"dateModified\":\"2022-06-24T08:06:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/\"},\"wordCount\":526,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2022\/04\/beitragsbild_ds_vakuumprozess.jpg\",\"keywords\":[\"Chemical\",\"Diaphragm seals\",\"Pressure\",\"Processtransmitter\"],\"articleSection\":[\"Applications\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/\",\"url\":\"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/\",\"name\":\"Lasting accuracy for diaphragm seal systems for vacuum process - WIKA blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2022\/04\/beitragsbild_ds_vakuumprozess.jpg\",\"datePublished\":\"2022-05-20T05:09:17+00:00\",\"dateModified\":\"2022-06-24T08:06:24+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/63ca8fb13617fef6c5b5e2985e493f80\"},\"description\":\"Falling pressure, rising temperature: A diaphragm seal system in the vacuum process must overcome a major challenge.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2022\/04\/beitragsbild_ds_vakuumprozess.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2022\/04\/beitragsbild_ds_vakuumprozess.jpg\",\"width\":838,\"height\":471,\"caption\":\"Diaphragm seal systems in the vacuum process face major challenges.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.wika.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Lasting accuracy for diaphragm seal systems for vacuum process\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/en\/#website\",\"url\":\"https:\/\/blog.wika.com\/en\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/63ca8fb13617fef6c5b5e2985e493f80\",\"name\":\"Jing Lyu\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/files\/2016\/05\/jing-lu-140x140.jpg\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2016\/05\/jing-lu-140x140.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2016\/05\/jing-lu-140x140.jpg\",\"caption\":\"Jing Lyu\"},\"description\":\"Since October 2015, I have been working at WIKA and am currently employed as a Content Marketing Manager. I am particularly interested in new customer solutions, innovative technologies, and forward-looking developments in measurement and sensor technology. With my articles, I aim to explain technical relationships in a simple and understandable way, provide guidance, and answer common questions in a practical manner \u2013 enabling users to quickly find the solutions that truly help them move forward.\",\"url\":\"https:\/\/blog.wika.com\/en\/author\/lujing\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Lasting accuracy for diaphragm seal systems for vacuum process - WIKA blog","description":"Falling pressure, rising temperature: A diaphragm seal system in the vacuum process must overcome a major challenge.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/","og_locale":"en_GB","og_type":"article","og_title":"Lasting accuracy for diaphragm seal systems for vacuum process - WIKA blog","og_description":"Falling pressure, rising temperature: A diaphragm seal system in the vacuum process must overcome a major challenge.","og_url":"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/","og_site_name":"WIKA blog","og_image":[{"width":838,"height":471,"url":"https:\/\/blog.wika.com\/en\/files\/2022\/04\/beitragsbild_ds_vakuumprozess.jpg","type":"image\/jpeg"}],"author":"Jing Lyu","twitter_misc":{"Written by":"Jing Lyu","Estimated reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/"},"author":{"name":"Jing Lyu","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/63ca8fb13617fef6c5b5e2985e493f80"},"headline":"Lasting accuracy for diaphragm seal systems for vacuum process","datePublished":"2022-05-20T05:09:17+00:00","dateModified":"2022-06-24T08:06:24+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/"},"wordCount":526,"commentCount":0,"image":{"@id":"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2022\/04\/beitragsbild_ds_vakuumprozess.jpg","keywords":["Chemical","Diaphragm seals","Pressure","Processtransmitter"],"articleSection":["Applications"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/","url":"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/","name":"Lasting accuracy for diaphragm seal systems for vacuum process - WIKA blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2022\/04\/beitragsbild_ds_vakuumprozess.jpg","datePublished":"2022-05-20T05:09:17+00:00","dateModified":"2022-06-24T08:06:24+00:00","author":{"@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/63ca8fb13617fef6c5b5e2985e493f80"},"description":"Falling pressure, rising temperature: A diaphragm seal system in the vacuum process must overcome a major challenge.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/#primaryimage","url":"https:\/\/blog.wika.com\/en\/files\/2022\/04\/beitragsbild_ds_vakuumprozess.jpg","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2022\/04\/beitragsbild_ds_vakuumprozess.jpg","width":838,"height":471,"caption":"Diaphragm seal systems in the vacuum process face major challenges."},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/en\/applications\/lasting-accuracy-for-diaphragm-seal-systems-for-vacuum-process\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/en\/"},{"@type":"ListItem","position":2,"name":"Lasting accuracy for diaphragm seal systems for vacuum process"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/en\/#website","url":"https:\/\/blog.wika.com\/en\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/63ca8fb13617fef6c5b5e2985e493f80","name":"Jing Lyu","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/files\/2016\/05\/jing-lu-140x140.jpg","url":"https:\/\/blog.wika.com\/en\/files\/2016\/05\/jing-lu-140x140.jpg","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2016\/05\/jing-lu-140x140.jpg","caption":"Jing Lyu"},"description":"Since October 2015, I have been working at WIKA and am currently employed as a Content Marketing Manager. I am particularly interested in new customer solutions, innovative technologies, and forward-looking developments in measurement and sensor technology. With my articles, I aim to explain technical relationships in a simple and understandable way, provide guidance, and answer common questions in a practical manner \u2013 enabling users to quickly find the solutions that truly help them move forward.","url":"https:\/\/blog.wika.com\/en\/author\/lujing\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/12952","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/users\/134"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/comments?post=12952"}],"version-history":[{"count":4,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/12952\/revisions"}],"predecessor-version":[{"id":13053,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/12952\/revisions\/13053"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media\/12955"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media?parent=12952"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/categories?post=12952"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/tags?post=12952"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}