{"id":448,"date":"2012-01-24T08:48:38","date_gmt":"2012-01-24T07:48:38","guid":{"rendered":"https:\/\/blog.wika.com\/en\/?p=448"},"modified":"2022-11-21T10:35:56","modified_gmt":"2022-11-21T09:35:56","slug":"pressure-equipment-directive-ped-pressure-limits","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/","title":{"rendered":"Pressure equipment directive 97\/23\/EC PED &#8211; Pressure limits 0.5 bar and 200 bar for pressure sensors and pressure transmitters"},"content":{"rendered":"<p>In connection with the pressure equipment directive 97\/23\/EC (PED), a pressure limit of 200 bar is often mentioned. But what does this limit mean for manufacturers and\/or companies that place pressure sensors, pressure transmitters and pressure equipment on the market? Generally it can be said that, depending on the type of medium to be measured (gaseous, liquid, harmful substance), pressure measuring instruments are subject to different requirements, depending on the pressure range and volume.<\/p>\n<p>If the medium is not known, it is best to design pressure measuring instruments conservatively, that is, also for harmful gaseous and liquid media, with a pressure channel and an internal volume of &lt; 0.1 l. Whereas it is sufficient that pressure equipment for up to 200 bar is generally designed and manufactured following the rules of &#8220;Good Engineering Practice&#8221; (GEP), for pressures from 200 bar, a conformity assessment procedure must be used, which in the simplest case can be an &#8220;internal production control&#8221;.<\/p>\n<p>For pressures from 200 bar, it is also required to meet the basic safety requirements of the PED Appendix I, which, among other things, requires a pressure test as proof of the pressure strength. An EC Declaration of Conformity must be prepared, and the instrument will be marked with CE. In any case, details should be looked up in the original text of the PED, while information on the interpretation of this directive can be found in the PED guidelines. Here are the most important key points:<\/p>\n<ol>\n<li>Pressure equipment for more than 0.5 bar is subject to the PED.<\/li>\n<li>Between 0.5 and 200 bar, &#8220;Good Engineering Practice&#8221; must be applied. No CE marking and Declaration of conformity possible according to the PED.<\/li>\n<li>At pressures greater than 200 bar, the &#8220;Basic Safety Requirements&#8221; of the PED Appendix I must be met, CE marking is required, and an EC Declaration of conformity according to the PED must be prepared.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>In connection with the pressure equipment directive 97\/23\/EC (PED), a pressure limit of 200 bar is often mentioned. But what does this limit mean for manufacturers and\/or companies that place pressure sensors, pressure transmitters and pressure equipment on the market? Generally it can be said that, depending on the type of medium to be measured [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":6382,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[220],"tags":[30,266,77],"class_list":["post-448","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pressure-products","tag-declaration-of-conformity","tag-measuring-range","tag-pressure-sensor"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Pressure limits for pressure sensors and transmitters - WIKA blog<\/title>\n<meta name=\"description\" content=\"In connection with the pressure equipment directive 97\/23\/EC (PED), a pressure limit of 200 bar is often mentioned. Find out more in this blog article!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Pressure limits for pressure sensors and transmitters - WIKA blog\" \/>\n<meta property=\"og:description\" content=\"In connection with the pressure equipment directive 97\/23\/EC (PED), a pressure limit of 200 bar is often mentioned. Find out more in this blog article!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/en\/files\/2012\/01\/200bar.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Dominik Lorenz\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Dominik Lorenz\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/\"},\"author\":{\"name\":\"Dominik Lorenz\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/962c6cf63b76cba07b4aa93e59329b65\"},\"headline\":\"Pressure equipment directive 97\/23\/EC PED &#8211; Pressure limits 0.5 bar and 200 bar for pressure sensors and pressure transmitters\",\"datePublished\":\"2012-01-24T07:48:38+00:00\",\"dateModified\":\"2022-11-21T09:35:56+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/\"},\"wordCount\":324,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2012\/01\/200bar.jpg\",\"keywords\":[\"Declaration of conformity\",\"Measuring range\",\"Pressure sensor\"],\"articleSection\":[\"Pressure\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/\",\"url\":\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/\",\"name\":\"Pressure limits for pressure sensors and transmitters - WIKA blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2012\/01\/200bar.jpg\",\"datePublished\":\"2012-01-24T07:48:38+00:00\",\"dateModified\":\"2022-11-21T09:35:56+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/962c6cf63b76cba07b4aa93e59329b65\"},\"description\":\"In connection with the pressure equipment directive 97\/23\/EC (PED), a pressure limit of 200 bar is often mentioned. Find out more in this blog article!\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2012\/01\/200bar.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2012\/01\/200bar.jpg\",\"width\":838,\"height\":471,\"caption\":\"pressure gauge - 200bar\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.wika.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pressure equipment directive 97\/23\/EC PED &#8211; Pressure limits 0.5 bar and 200 bar for pressure sensors and pressure transmitters\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/en\/#website\",\"url\":\"https:\/\/blog.wika.com\/en\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/962c6cf63b76cba07b4aa93e59329b65\",\"name\":\"Dominik Lorenz\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png\",\"caption\":\"Dominik Lorenz\"},\"url\":\"https:\/\/blog.wika.com\/en\/author\/lodo80\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Pressure limits for pressure sensors and transmitters - WIKA blog","description":"In connection with the pressure equipment directive 97\/23\/EC (PED), a pressure limit of 200 bar is often mentioned. Find out more in this blog article!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/","og_locale":"en_GB","og_type":"article","og_title":"Pressure limits for pressure sensors and transmitters - WIKA blog","og_description":"In connection with the pressure equipment directive 97\/23\/EC (PED), a pressure limit of 200 bar is often mentioned. Find out more in this blog article!","og_url":"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/","og_site_name":"WIKA blog","og_image":[{"width":838,"height":471,"url":"https:\/\/blog.wika.com\/en\/files\/2012\/01\/200bar.jpg","type":"image\/jpeg"}],"author":"Dominik Lorenz","twitter_misc":{"Written by":"Dominik Lorenz","Estimated reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/"},"author":{"name":"Dominik Lorenz","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/962c6cf63b76cba07b4aa93e59329b65"},"headline":"Pressure equipment directive 97\/23\/EC PED &#8211; Pressure limits 0.5 bar and 200 bar for pressure sensors and pressure transmitters","datePublished":"2012-01-24T07:48:38+00:00","dateModified":"2022-11-21T09:35:56+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/"},"wordCount":324,"image":{"@id":"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2012\/01\/200bar.jpg","keywords":["Declaration of conformity","Measuring range","Pressure sensor"],"articleSection":["Pressure"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/","url":"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/","name":"Pressure limits for pressure sensors and transmitters - WIKA blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2012\/01\/200bar.jpg","datePublished":"2012-01-24T07:48:38+00:00","dateModified":"2022-11-21T09:35:56+00:00","author":{"@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/962c6cf63b76cba07b4aa93e59329b65"},"description":"In connection with the pressure equipment directive 97\/23\/EC (PED), a pressure limit of 200 bar is often mentioned. Find out more in this blog article!","breadcrumb":{"@id":"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/#primaryimage","url":"https:\/\/blog.wika.com\/en\/files\/2012\/01\/200bar.jpg","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2012\/01\/200bar.jpg","width":838,"height":471,"caption":"pressure gauge - 200bar"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/en\/products\/pressure-products\/pressure-equipment-directive-ped-pressure-limits\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/en\/"},{"@type":"ListItem","position":2,"name":"Pressure equipment directive 97\/23\/EC PED &#8211; Pressure limits 0.5 bar and 200 bar for pressure sensors and pressure transmitters"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/en\/#website","url":"https:\/\/blog.wika.com\/en\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/962c6cf63b76cba07b4aa93e59329b65","name":"Dominik Lorenz","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png","url":"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png","caption":"Dominik Lorenz"},"url":"https:\/\/blog.wika.com\/en\/author\/lodo80\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/448","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/comments?post=448"}],"version-history":[{"count":9,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/448\/revisions"}],"predecessor-version":[{"id":12526,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/448\/revisions\/12526"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media\/6382"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media?parent=448"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/categories?post=448"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/tags?post=448"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}