{"id":6729,"date":"2015-09-02T10:30:58","date_gmt":"2015-09-02T09:30:58","guid":{"rendered":"https:\/\/blog.wika.com\/en\/?p=6729"},"modified":"2019-09-03T08:40:37","modified_gmt":"2019-09-03T06:40:37","slug":"verification-or-calibration","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/","title":{"rendered":"Verification or calibration?"},"content":{"rendered":"<p><strong>In general usage, the term &#8220;verification&#8221; is often mixed up with &#8220;calibration&#8221;. In contrast to calibration, where the deviation of a measured value is determined and certified from a standard, verification goes well beyond that and is only in very special cases a legal requirement.<\/strong><\/p>\n<p>For a number of measuring instruments, a state-driven legal requirement for verification exists. That means that they may only be used if they have been verified by a nationally recognised testing laboratory. Verification is therefore the state-required testing of measuring instruments. In doing this, based on a consistency quality test, it is determined whether the measuring instruments are able to be verified. In the subsequent metrological testing it is checked whether the measuring instrument complies with the specified maximum permissible errors and conforms to other requirements that are defined in the verification ordinance or in the EU directives. Included in this category are such as water meters, commercial scales, petrol pumps, radar measuring instruments or measuring equipment for automotive exhaust gases. In addition, pressure gauges must therefore only be verified if their suitability (for example because of a specific measurement accuracy) serves to protect the health and safety of people or to measure dimensions in the free movement of goods.<\/p>\n<h2>Overview of the differences between verfication and calibration<\/h2>\n<table style=\"height: 331px\" width=\"834\">\n<tbody>\n<tr>\n<td><strong>Verification<\/strong><\/td>\n<td><strong>Calibration<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<p>Verification &#8211; Only when it is a legal requirement (not ISO9000ff):<\/p>\n<ul>\n<li style=\"list-style-type: none\">\n<ul>\n<li>Determining compliance with legally prescribed verification error limits<\/li>\n<li>Officially recognised and legally binding verification testing<\/li>\n<li>Verification certification or conformity certificate (&#8220;initial verification&#8221;)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/td>\n<td>\n<p>DKD calibration &#8211; Specifically if metrological traceability is necessary:<\/p>\n<ul>\n<li style=\"list-style-type: none\">\n<ul>\n<li>Per calibration point, the deviation and measurement uncertainty is determined and documented in the calibration certificate<\/li>\n<li>Trusted measuring results with traceability to international standards<\/li>\n<li>DKD calibration certificate<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Note<br \/>\n<\/strong>The WIKA calibration laboratory is accredited by the German Accreditation Body (Deutsche Akkreditierungsstelle &#8211; DAkkS) in accordance with DIN EN ISO \/ IEC 17025 for the measurement parameters temperature, pressure, DC current, DC voltage and DC resistance.\u00a0If you are interested in our services, please feel free to contact us at <span><a href=\"mailto:CTServiceTeam@wika.com\">CTServiceTeam@wika.com<\/a><\/span>.<\/p>\n<p>Find out more about the differences between calibration, verification and adjustment in the following video:<\/p>\n<div data-fullscreen=\"disabled\" data-mode=\"normal\" data-oembed=\"1\" data-provider=\"youtube\" data-reset-after-played id=\"arve-youtube-auqymtuamos\" style=\"max-width:900px;\" class=\"arve\">\n<div class=\"arve-inner\">\n<div style=\"aspect-ratio:500\/281\" class=\"arve-embed arve-embed--has-aspect-ratio\">\n<div class=\"arve-ar\" style=\"padding-top:56.200000%\"><\/div>\n<p>\t\t\t<iframe allow=\"accelerometer &apos;none&apos;;autoplay &apos;none&apos;;bluetooth &apos;none&apos;;browsing-topics &apos;none&apos;;camera &apos;none&apos;;clipboard-read &apos;none&apos;;clipboard-write;display-capture &apos;none&apos;;encrypted-media &apos;none&apos;;gamepad &apos;none&apos;;geolocation &apos;none&apos;;gyroscope &apos;none&apos;;hid &apos;none&apos;;identity-credentials-get &apos;none&apos;;idle-detection &apos;none&apos;;keyboard-map &apos;none&apos;;local-fonts;magnetometer &apos;none&apos;;microphone &apos;none&apos;;midi &apos;none&apos;;otp-credentials &apos;none&apos;;payment &apos;none&apos;;picture-in-picture;publickey-credentials-create &apos;none&apos;;publickey-credentials-get &apos;none&apos;;screen-wake-lock &apos;none&apos;;serial &apos;none&apos;;summarizer &apos;none&apos;;sync-xhr;usb &apos;none&apos;;web-share;window-management &apos;none&apos;;xr-spatial-tracking &apos;none&apos;;\" allowfullscreen=\"\" class=\"arve-iframe fitvidsignore\" credentialless data-arve=\"arve-youtube-auqymtuamos\" data-lenis-prevent=\"\" data-src-no-ap=\"https:\/\/www.youtube-nocookie.com\/embed\/aUQyMTUAMos?feature=oembed&amp;iv_load_policy=3&amp;modestbranding=1&amp;rel=0&amp;autohide=1&amp;playsinline=0&amp;autoplay=0&amp;enablejsapi=1\" frameborder=\"0\" height=\"505.8\" loading=\"lazy\" name=\"\" referrerpolicy=\"strict-origin-when-cross-origin\" sandbox=\"allow-scripts allow-same-origin allow-presentation allow-popups allow-popups-to-escape-sandbox\" scrolling=\"no\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/aUQyMTUAMos?feature=oembed&#038;iv_load_policy=3&#038;modestbranding=1&#038;rel=0&#038;autohide=1&#038;playsinline=0&#038;autoplay=0&#038;enablejsapi=1\" title=\"Calibration of measuring instruments | Definition of calibration, verification and adjustment\" width=\"900\"><\/iframe><\/p><\/div>\n<\/p><\/div>\n<p>\t<script type=\"application\/ld+json\">{\"@context\":\"http:\\\/\\\/schema.org\\\/\",\"@id\":\"https:\\\/\\\/blog.wika.com\\\/en\\\/knowhow\\\/verification-or-calibration\\\/#arve-youtube-auqymtuamos\",\"type\":\"VideoObject\",\"embedURL\":\"https:\\\/\\\/www.youtube-nocookie.com\\\/embed\\\/aUQyMTUAMos?feature=oembed&iv_load_policy=3&modestbranding=1&rel=0&autohide=1&playsinline=0&autoplay=0&enablejsapi=1\",\"name\":\"Calibration of measuring instruments | Definition of calibration, verification and adjustment\",\"thumbnailUrl\":\"https:\\\/\\\/i.ytimg.com\\\/vi\\\/aUQyMTUAMos\\\/hqdefault.jpg\",\"uploadDate\":\"2019-01-15T07:40:07Z\",\"author\":\"WIKA Group\",\"description\":\"Every measuring instrument is subject to ageing as a result of mechanical, chemical or thermal stress and thus delivers measured values that change over time. This cannot be prevented, but it can be detected in good time by calibration. In this video, we will explain the calibration of instruments and the differences between a calibration and a verification - and when an adjustment must be made.\\n\\n\\u25ac Contents of this video \\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\u25ac\\n00:00 - Intro\\n00:04 - Calibration - Adjustment - Verification\\n00:37 - What is calibration of measuring instrument?\\n01:22 - What is adjustment?\\n01:34 - What is verification?\\n01:49 - WIKA Laboratories calibration services\\n\\n#CalibrationOfInstruments #Calibration #WIKAgroup #CalibrationMeasuringInstruments #InstrumentCalibration\\n\\nIn the process of calibration, the displayed value of the measuring instrument is compared with the measuring result of a different measuring device which is known to function correctly and accurately, and which itself has been made to coincide directly or indirectly with a national or international reference instrument (standard). If the result of the examination is within the manufacturer's specifications, then a calibration certificate will be issued with the corresponding confirmation.\\n\\nOne talks about verification when the calibration has been carried out or supervised by an official body. Both of these variants are purely intended for determining the quality of the displayed values. No intervention to the measuring instrument itself is allowed.\\n\\nWith adjustment it is understood that there is an intervention to the measuring device, in order to minimise a detected measuring deviation. Typically, adjustment is followed by a further calibration, in order to check and document the final state of the measuring instrument following the intervention.\\n\\nIn contrast to verification, which will lose its validity after a period of time set by law, the validity period of a calibration is subject to practical specifications such as manufacturer's instructions, requirements of a quality assurance standard or in-house and customer-specific regulations. Calibration must also be carried out when the measuring instrument is used for the manufacture of products which are subject to official supervision such as drugs or foodstuffs.\\n\\nIn the WIKA calibration laboratories, you can have your measuring instruments calibrated, adjusted and verified. \\n\\n\\ud83d\\udcd6 Further articles on the subject of calibration can be found in our blog:\\n- Calibration or adjustment \\u2013 Where's the difference? \\n- Verification or calibration? \\n_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ \\n\\nFollow us on our social media channels:\\n\\ud83d\\udcfa YouTube: \\n\\ud83c\\udfaf LinkedIn:\"}<\/script><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>In general usage, the term &#8220;verification&#8221; is often mixed up with &#8220;calibration&#8221;. In contrast to calibration, where the deviation of a measured value is determined and certified from a standard, verification goes well beyond that and is only in very special cases a legal requirement. For a number of measuring instruments, a state-driven legal requirement [&hellip;]<\/p>\n","protected":false},"author":105,"featured_media":6730,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5],"tags":[15,56,75],"class_list":["post-6729","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowhow","tag-accuracy","tag-measuring-principles","tag-pressure-gauge"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Verify or calibrate measuring instruments? - WIKA blog<\/title>\n<meta name=\"description\" content=\"What is the difference between a verification and a calibration? Find out more about the different test methods for measuring instruments in the WIKA blog.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Verify or calibrate measuring instruments? - WIKA blog\" \/>\n<meta property=\"og:description\" content=\"What is the difference between a verification and a calibration? Find out more about the different test methods for measuring instruments in the WIKA blog.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/en\/files\/2015\/08\/kalibrieraufkleber.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"837\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Christian Elbert\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Christian Elbert\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/\"},\"author\":{\"name\":\"Christian Elbert\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/41dd5b7e2f43e892c042876252ea6cd5\"},\"headline\":\"Verification or calibration?\",\"datePublished\":\"2015-09-02T09:30:58+00:00\",\"dateModified\":\"2019-09-03T06:40:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/\"},\"wordCount\":364,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2015\/08\/kalibrieraufkleber.jpg\",\"keywords\":[\"Accuracy\",\"Measuring principles\",\"Pressure gauge\"],\"articleSection\":[\"Know-how\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/\",\"url\":\"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/\",\"name\":\"Verify or calibrate measuring instruments? - WIKA blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2015\/08\/kalibrieraufkleber.jpg\",\"datePublished\":\"2015-09-02T09:30:58+00:00\",\"dateModified\":\"2019-09-03T06:40:37+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/41dd5b7e2f43e892c042876252ea6cd5\"},\"description\":\"What is the difference between a verification and a calibration? Find out more about the different test methods for measuring instruments in the WIKA blog.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2015\/08\/kalibrieraufkleber.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2015\/08\/kalibrieraufkleber.jpg\",\"width\":837,\"height\":471,\"caption\":\"certified pressure gauge\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.wika.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Verification or calibration?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/en\/#website\",\"url\":\"https:\/\/blog.wika.com\/en\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/41dd5b7e2f43e892c042876252ea6cd5\",\"name\":\"Christian Elbert\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/files\/2018\/08\/elbertchristian-140x140.jpg\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2018\/08\/elbertchristian-140x140.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2018\/08\/elbertchristian-140x140.jpg\",\"caption\":\"Christian Elbert\"},\"description\":\"In addition to my work at WIKA , I am active in various professional commitees around the calibration . This allows to consider issues from different perspectives and to create the best possible added value for the interested reader. You should take this as an encouragement for further questions and discussions . I look forward to your feedback.\",\"url\":\"https:\/\/blog.wika.com\/en\/author\/elbertc\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Verify or calibrate measuring instruments? - WIKA blog","description":"What is the difference between a verification and a calibration? Find out more about the different test methods for measuring instruments in the WIKA blog.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/","og_locale":"en_GB","og_type":"article","og_title":"Verify or calibrate measuring instruments? - WIKA blog","og_description":"What is the difference between a verification and a calibration? Find out more about the different test methods for measuring instruments in the WIKA blog.","og_url":"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/","og_site_name":"WIKA blog","og_image":[{"width":837,"height":471,"url":"https:\/\/blog.wika.com\/en\/files\/2015\/08\/kalibrieraufkleber.jpg","type":"image\/jpeg"}],"author":"Christian Elbert","twitter_misc":{"Written by":"Christian Elbert","Estimated reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/"},"author":{"name":"Christian Elbert","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/41dd5b7e2f43e892c042876252ea6cd5"},"headline":"Verification or calibration?","datePublished":"2015-09-02T09:30:58+00:00","dateModified":"2019-09-03T06:40:37+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/"},"wordCount":364,"commentCount":0,"image":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2015\/08\/kalibrieraufkleber.jpg","keywords":["Accuracy","Measuring principles","Pressure gauge"],"articleSection":["Know-how"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/","url":"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/","name":"Verify or calibrate measuring instruments? - WIKA blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2015\/08\/kalibrieraufkleber.jpg","datePublished":"2015-09-02T09:30:58+00:00","dateModified":"2019-09-03T06:40:37+00:00","author":{"@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/41dd5b7e2f43e892c042876252ea6cd5"},"description":"What is the difference between a verification and a calibration? Find out more about the different test methods for measuring instruments in the WIKA blog.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/#primaryimage","url":"https:\/\/blog.wika.com\/en\/files\/2015\/08\/kalibrieraufkleber.jpg","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2015\/08\/kalibrieraufkleber.jpg","width":837,"height":471,"caption":"certified pressure gauge"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/en\/knowhow\/verification-or-calibration\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/en\/"},{"@type":"ListItem","position":2,"name":"Verification or calibration?"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/en\/#website","url":"https:\/\/blog.wika.com\/en\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/41dd5b7e2f43e892c042876252ea6cd5","name":"Christian Elbert","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/files\/2018\/08\/elbertchristian-140x140.jpg","url":"https:\/\/blog.wika.com\/en\/files\/2018\/08\/elbertchristian-140x140.jpg","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2018\/08\/elbertchristian-140x140.jpg","caption":"Christian Elbert"},"description":"In addition to my work at WIKA , I am active in various professional commitees around the calibration . This allows to consider issues from different perspectives and to create the best possible added value for the interested reader. You should take this as an encouragement for further questions and discussions . I look forward to your feedback.","url":"https:\/\/blog.wika.com\/en\/author\/elbertc\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/6729","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/users\/105"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/comments?post=6729"}],"version-history":[{"count":9,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/6729\/revisions"}],"predecessor-version":[{"id":9027,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/6729\/revisions\/9027"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media\/6730"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media?parent=6729"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/categories?post=6729"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/tags?post=6729"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}