{"id":6969,"date":"2016-09-05T13:10:24","date_gmt":"2016-09-05T11:10:24","guid":{"rendered":"https:\/\/blog.wika.com\/en\/?p=6969"},"modified":"2023-08-31T13:55:21","modified_gmt":"2023-08-31T11:55:21","slug":"signal-clamping-in-pressure-transmitters","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/","title":{"rendered":"Signal clamping in pressure transmitters"},"content":{"rendered":"<p><strong>In certain applications, the current or voltage signal of a pressure transmitter must not exceed and\/or drop below a critical value. This can be ensured with the aid of so-called signal limiting.<\/strong><\/p>\n<h2>Why is a signal clamping necessary in the first place?<\/h2>\n<p>If the pressure on a pressure transmitter lies within the nominal pressure range, then there will be a defined signal output (e.g. 4 \u2026 20 mA or 0 \u2026 10 V). However, in technical applications, it frequently happens that an originally planned pressure range is exceeded or is dropped below. This can happen deliberately, for example when cleaning, as well as accidentally, for example through load variations or in the event of a fault. In these cases, the sensor signal will also move outside the defined limits, so that, for example, a current signal in the range of 3.6 to 25 mA can occur.<\/p>\n<p>If now, however, the evaluation electronics are set so that they recognise a signal outside of the defined limits as an error, in some situations, trouble-free operation of the entire system cannot be ensured anymore. In these cases, a signal limiting of the pressure transmitter makes sense, so that the output signal is maintained within the required range (e.g. 3.8 \u2026 21 mA).<\/p>\n<p><strong>Note<br \/>\n<\/strong>An example of a pressure transmitter with which the voltage signal and also the current signal can be limited is the model <a href=\"https:\/\/www.wika.com\/en-en\/s_20.WIKA\" rel=\"external\" target=\"_blank\">S-20<\/a> (for general industrial applications) or the model <a href=\"https:\/\/www.wika.com\/en-en\/mh_4.WIKA\" rel=\"external\" target=\"_blank\">MH-4<\/a> (for mobile working machines) from WIKA.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In certain applications, the current or voltage signal of a pressure transmitter must not exceed and\/or drop below a critical value. This can be ensured with the aid of so-called signal limiting. Why is a signal clamping necessary in the first place? If the pressure on a pressure transmitter lies within the nominal pressure range, [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":7231,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5],"tags":[77],"class_list":["post-6969","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowhow","tag-pressure-sensor"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Signal clamping in pressure transmitters - WIKA blog<\/title>\n<meta name=\"description\" content=\"Sometimes, the signal of a pressure transmitter must not exceed and\/or drop below a critical value. This can be ensured with the aid of so-called signal limiting.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Signal clamping in pressure transmitters - WIKA blog\" \/>\n<meta property=\"og:description\" content=\"Sometimes, the signal of a pressure transmitter must not exceed and\/or drop below a critical value. This can be ensured with the aid of so-called signal limiting.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/en\/files\/2016\/04\/signal-clamping.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Mich\u00e8le Beyer\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Mich\u00e8le Beyer\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/\"},\"author\":{\"name\":\"Mich\u00e8le Beyer\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/13ca97d373c6de6a796587c8d415527a\"},\"headline\":\"Signal clamping in pressure transmitters\",\"datePublished\":\"2016-09-05T11:10:24+00:00\",\"dateModified\":\"2023-08-31T11:55:21+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/\"},\"wordCount\":244,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2016\/04\/signal-clamping.jpg\",\"keywords\":[\"Pressure sensor\"],\"articleSection\":[\"Know-how\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/\",\"url\":\"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/\",\"name\":\"Signal clamping in pressure transmitters - WIKA blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2016\/04\/signal-clamping.jpg\",\"datePublished\":\"2016-09-05T11:10:24+00:00\",\"dateModified\":\"2023-08-31T11:55:21+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/13ca97d373c6de6a796587c8d415527a\"},\"description\":\"Sometimes, the signal of a pressure transmitter must not exceed and\/or drop below a critical value. This can be ensured with the aid of so-called signal limiting.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2016\/04\/signal-clamping.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2016\/04\/signal-clamping.jpg\",\"width\":838,\"height\":471,\"caption\":\"Signal clamping\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.wika.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Signal clamping in pressure transmitters\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/en\/#website\",\"url\":\"https:\/\/blog.wika.com\/en\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/13ca97d373c6de6a796587c8d415527a\",\"name\":\"Mich\u00e8le Beyer\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/files\/2017\/05\/beyer-michele-140x140.jpg\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2017\/05\/beyer-michele-140x140.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2017\/05\/beyer-michele-140x140.jpg\",\"caption\":\"Mich\u00e8le Beyer\"},\"description\":\"I joined WIKA in 1998 and have been working from the start in product management. Every day I answer a wide range of questions on the topic of electronic pressure measurement. Many questions are asked over and over again by WIKA staff and customers from all over the world. So why not answer the most interesting questions in this blog?\",\"url\":\"https:\/\/blog.wika.com\/en\/author\/bemi73\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Signal clamping in pressure transmitters - WIKA blog","description":"Sometimes, the signal of a pressure transmitter must not exceed and\/or drop below a critical value. This can be ensured with the aid of so-called signal limiting.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/","og_locale":"en_GB","og_type":"article","og_title":"Signal clamping in pressure transmitters - WIKA blog","og_description":"Sometimes, the signal of a pressure transmitter must not exceed and\/or drop below a critical value. This can be ensured with the aid of so-called signal limiting.","og_url":"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/","og_site_name":"WIKA blog","og_image":[{"width":838,"height":471,"url":"https:\/\/blog.wika.com\/en\/files\/2016\/04\/signal-clamping.jpg","type":"image\/jpeg"}],"author":"Mich\u00e8le Beyer","twitter_misc":{"Written by":"Mich\u00e8le Beyer","Estimated reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/"},"author":{"name":"Mich\u00e8le Beyer","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/13ca97d373c6de6a796587c8d415527a"},"headline":"Signal clamping in pressure transmitters","datePublished":"2016-09-05T11:10:24+00:00","dateModified":"2023-08-31T11:55:21+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/"},"wordCount":244,"commentCount":0,"image":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2016\/04\/signal-clamping.jpg","keywords":["Pressure sensor"],"articleSection":["Know-how"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/","url":"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/","name":"Signal clamping in pressure transmitters - WIKA blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2016\/04\/signal-clamping.jpg","datePublished":"2016-09-05T11:10:24+00:00","dateModified":"2023-08-31T11:55:21+00:00","author":{"@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/13ca97d373c6de6a796587c8d415527a"},"description":"Sometimes, the signal of a pressure transmitter must not exceed and\/or drop below a critical value. This can be ensured with the aid of so-called signal limiting.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/#primaryimage","url":"https:\/\/blog.wika.com\/en\/files\/2016\/04\/signal-clamping.jpg","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2016\/04\/signal-clamping.jpg","width":838,"height":471,"caption":"Signal clamping"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/en\/knowhow\/signal-clamping-in-pressure-transmitters\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/en\/"},{"@type":"ListItem","position":2,"name":"Signal clamping in pressure transmitters"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/en\/#website","url":"https:\/\/blog.wika.com\/en\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/13ca97d373c6de6a796587c8d415527a","name":"Mich\u00e8le Beyer","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/files\/2017\/05\/beyer-michele-140x140.jpg","url":"https:\/\/blog.wika.com\/en\/files\/2017\/05\/beyer-michele-140x140.jpg","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2017\/05\/beyer-michele-140x140.jpg","caption":"Mich\u00e8le Beyer"},"description":"I joined WIKA in 1998 and have been working from the start in product management. Every day I answer a wide range of questions on the topic of electronic pressure measurement. Many questions are asked over and over again by WIKA staff and customers from all over the world. So why not answer the most interesting questions in this blog?","url":"https:\/\/blog.wika.com\/en\/author\/bemi73\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/6969","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/comments?post=6969"}],"version-history":[{"count":10,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/6969\/revisions"}],"predecessor-version":[{"id":50886,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/6969\/revisions\/50886"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media\/7231"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media?parent=6969"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/categories?post=6969"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/tags?post=6969"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}