{"id":7410,"date":"2017-03-16T18:26:12","date_gmt":"2017-03-16T17:26:12","guid":{"rendered":"https:\/\/blog.wika.com\/en\/?p=7410"},"modified":"2023-08-31T13:30:42","modified_gmt":"2023-08-31T11:30:42","slug":"against-overheating-differential-pressure-gauges-as-flow-monitors","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/","title":{"rendered":"Against overheating: Differential pressure gauges as flow monitors"},"content":{"rendered":"<p><strong>Differential pressure gauges are not only suitable for the typical applications such as monitoring and control of filters or pumps. They can take on the function of a flow monitor, for example, in heat transfer oil plants. They thus control the volume flow of the medium. The reliability of the measuring instrument can be attested for this application through a certification in accordance with VdT\u00dcV (\u201cFlow 100\u201d code of practice).<\/strong><\/p>\n\n      <div class=\"wp-caption alignright\" style=\"max-width:396px;\"><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/en\/wp-content\/blogs.dir\/18\/files\/2016\/09\/waermetraegeroelanlage_neu-388x237.jpg\" alt=\"Heat transfer oil plant\" \/><p class=\"wp-caption-text\">Heat transfer oil plant<\/p><\/div>\n    \n<p>A look at its measurement principle makes it clear why a differential pressure gauge can be suitable as a flow control: It collects the pressure from two different points in the process and displays the measured value of the differential pressure. This information indicates the particular flow characteristics of the medium: The higher the value, the stronger the flow.<\/p>\n<p>For the task as a <a href=\"https:\/\/www.wika.com\/en-en\/flow_switches.WIKA\" rel=\"external\" target=\"_blank\">flow monitor<\/a> in heat transfer oil plants, however, only differential pressure gauges in a mechatronic design with switch contacts come into consideration. Plants with thermal oil are used for the tempering of processes in various industries. If the flow of the oil slows down, the differential pressure in the line between the two measuring points drops. The instrument indicates this and reacts automatically in the event of danger: Its pressure switch triggers an alarm when a preset critical measured value is reached and switches the heater off or stops the process. Thus, a block of hot medium of up to 400 \u00b0C and, as a possible consequence, an overheating of the plant at a single point, is prevented.<\/p>\n\n      <div class=\"wp-caption alignleft\" style=\"max-width:395px;\"><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/en\/files\/2020\/01\/dpgs40ta-mit-vdt\u00dcv_neu_60-e1472134560511.jpg\" \/><p class=\"wp-caption-text\">Str\u00f6mungsw\u00e4chter DPGS40TA<\/p><\/div>\n    \n<h2>Up to two switch contacts<\/h2>\n<p>For the requirements for differential pressure flow monitoring in heat transfer oil plants, instruments like the WIKA model <a href=\"https:\/\/www.wika.com\/en-en\/dpgs40ta.WIKA\" rel=\"external\" target=\"_blank\">DPGS40TA<\/a> from the DELTA-line product family are tailor-made (available both in an aluminium and a stainless steel version). The VdT\u00dcV certificate confirms the reliability of the correct registration of the differential pressure and of the switch function. Given the potential risk in the process, plant operators require a component testing in accordance with the &#8216;Flow 100&#8217; VdT\u00dcV code of practice for such instruments. The <a href=\"https:\/\/www.wika.com\/en-en\/dpgs40ta.WIKA\" rel=\"external\" target=\"_blank\">DPGS40TA<\/a> also has a shipbuilding approval, certified in accordance with DNV-GL, and is available with a SIL certificate for safety applications. It features up to two switch contacts and an integrated working pressure indication.<\/p>\n<p><strong>Note<br \/>\n<\/strong>Further information on the <a href=\"https:\/\/www.wika.com\/en-en\/lp_differential_pressure_gauge.WIKA\" rel=\"external\" target=\"_blank\">differential pressure gauges<\/a> of the DELTA-line product family (models <a href=\"https:\/\/www.wika.com\/en-en\/dpgs40ta.WIKA\" rel=\"external\" target=\"_blank\">DPGS40TA<\/a>, <a href=\"https:\/\/www.wika.com\/de-de\/dpg40.WIKA\" rel=\"external\" target=\"_blank\">DPG40<\/a>, <a href=\"https:\/\/www.wika.com\/de-de\/dpgt40.WIKA\" rel=\"external\" target=\"_blank\">DPGT40<\/a>, <a href=\"https:\/\/www.wika.com\/en-en\/dps40.WIKA\" rel=\"external\" target=\"_blank\">DPS40<\/a>, <a href=\"https:\/\/www.wika.com\/en-en\/dpgs40.WIKA\" rel=\"external\" target=\"_blank\">DPGS40<\/a>) can be found on the WIKA website and also in the<a href=\"http:\/\/en-co.wika.de\/upload\/FL_DeltaLine_en_co_70583.pdf\" rel=\"external\" target=\"_blank\"> flyer \u201cDELTA-line\u201d (PDF)<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Differential pressure gauges are not only suitable for the typical applications such as monitoring and control of filters or pumps. They can take on the function of a flow monitor, for example, in heat transfer oil plants. They thus control the volume flow of the medium. The reliability of the measuring instrument can be attested [&hellip;]<\/p>\n","protected":false},"author":123,"featured_media":7415,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5],"tags":[75,575],"class_list":["post-7410","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowhow","tag-pressure-gauge","tag-pressure-measurement-device"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Differential pressure gauges as flow monitors - WIKA blog<\/title>\n<meta name=\"description\" content=\"Differential pressure gauges can take on the function of a flow monitor, e.g. in heat transfer oil plants and can control the volume flow of the medium.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Differential pressure gauges as flow monitors - WIKA blog\" \/>\n<meta property=\"og:description\" content=\"Differential pressure gauges can take on the function of a flow monitor, e.g. in heat transfer oil plants and can control the volume flow of the medium.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/en\/files\/2016\/09\/beitragsbild_kamera_\u00a9pixinoo-fotolia.com_neu.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"472\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Manuel Schwestka\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Manuel Schwestka\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/\"},\"author\":{\"name\":\"Manuel Schwestka\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/7f727075b4fcb0d1711cbb24627cb275\"},\"headline\":\"Against overheating: Differential pressure gauges as flow monitors\",\"datePublished\":\"2017-03-16T17:26:12+00:00\",\"dateModified\":\"2023-08-31T11:30:42+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/\"},\"wordCount\":440,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2016\/09\/beitragsbild_kamera_\u00a9pixinoo-fotolia.com_neu.jpg\",\"keywords\":[\"Pressure gauge\",\"Pressure measurement device\"],\"articleSection\":[\"Know-how\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/\",\"url\":\"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/\",\"name\":\"Differential pressure gauges as flow monitors - WIKA blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2016\/09\/beitragsbild_kamera_\u00a9pixinoo-fotolia.com_neu.jpg\",\"datePublished\":\"2017-03-16T17:26:12+00:00\",\"dateModified\":\"2023-08-31T11:30:42+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/7f727075b4fcb0d1711cbb24627cb275\"},\"description\":\"Differential pressure gauges can take on the function of a flow monitor, e.g. in heat transfer oil plants and can control the volume flow of the medium.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2016\/09\/beitragsbild_kamera_\u00a9pixinoo-fotolia.com_neu.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2016\/09\/beitragsbild_kamera_\u00a9pixinoo-fotolia.com_neu.jpg\",\"width\":838,\"height\":472,\"caption\":\"Differential pressure gauges as flow monitors\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.wika.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Against overheating: Differential pressure gauges as flow monitors\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/en\/#website\",\"url\":\"https:\/\/blog.wika.com\/en\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/7f727075b4fcb0d1711cbb24627cb275\",\"name\":\"Manuel Schwestka\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png\",\"caption\":\"Manuel Schwestka\"},\"url\":\"https:\/\/blog.wika.com\/en\/author\/schwestm\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Differential pressure gauges as flow monitors - WIKA blog","description":"Differential pressure gauges can take on the function of a flow monitor, e.g. in heat transfer oil plants and can control the volume flow of the medium.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/","og_locale":"en_GB","og_type":"article","og_title":"Differential pressure gauges as flow monitors - WIKA blog","og_description":"Differential pressure gauges can take on the function of a flow monitor, e.g. in heat transfer oil plants and can control the volume flow of the medium.","og_url":"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/","og_site_name":"WIKA blog","og_image":[{"width":838,"height":472,"url":"https:\/\/blog.wika.com\/en\/files\/2016\/09\/beitragsbild_kamera_\u00a9pixinoo-fotolia.com_neu.jpg","type":"image\/jpeg"}],"author":"Manuel Schwestka","twitter_misc":{"Written by":"Manuel Schwestka","Estimated reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/"},"author":{"name":"Manuel Schwestka","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/7f727075b4fcb0d1711cbb24627cb275"},"headline":"Against overheating: Differential pressure gauges as flow monitors","datePublished":"2017-03-16T17:26:12+00:00","dateModified":"2023-08-31T11:30:42+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/"},"wordCount":440,"commentCount":0,"image":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2016\/09\/beitragsbild_kamera_\u00a9pixinoo-fotolia.com_neu.jpg","keywords":["Pressure gauge","Pressure measurement device"],"articleSection":["Know-how"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/","url":"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/","name":"Differential pressure gauges as flow monitors - WIKA blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2016\/09\/beitragsbild_kamera_\u00a9pixinoo-fotolia.com_neu.jpg","datePublished":"2017-03-16T17:26:12+00:00","dateModified":"2023-08-31T11:30:42+00:00","author":{"@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/7f727075b4fcb0d1711cbb24627cb275"},"description":"Differential pressure gauges can take on the function of a flow monitor, e.g. in heat transfer oil plants and can control the volume flow of the medium.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/#primaryimage","url":"https:\/\/blog.wika.com\/en\/files\/2016\/09\/beitragsbild_kamera_\u00a9pixinoo-fotolia.com_neu.jpg","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2016\/09\/beitragsbild_kamera_\u00a9pixinoo-fotolia.com_neu.jpg","width":838,"height":472,"caption":"Differential pressure gauges as flow monitors"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/en\/knowhow\/against-overheating-differential-pressure-gauges-as-flow-monitors\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/en\/"},{"@type":"ListItem","position":2,"name":"Against overheating: Differential pressure gauges as flow monitors"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/en\/#website","url":"https:\/\/blog.wika.com\/en\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/7f727075b4fcb0d1711cbb24627cb275","name":"Manuel Schwestka","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png","url":"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2015\/03\/default_avatar-140x140.png","caption":"Manuel Schwestka"},"url":"https:\/\/blog.wika.com\/en\/author\/schwestm\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/7410","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/users\/123"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/comments?post=7410"}],"version-history":[{"count":18,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/7410\/revisions"}],"predecessor-version":[{"id":50876,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/7410\/revisions\/50876"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media\/7415"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media?parent=7410"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/categories?post=7410"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/tags?post=7410"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}