{"id":7984,"date":"2017-09-07T09:30:47","date_gmt":"2017-09-07T07:30:47","guid":{"rendered":"https:\/\/blog.wika.com\/en\/?p=7984"},"modified":"2021-08-26T08:16:28","modified_gmt":"2021-08-26T06:16:28","slug":"economical-monitoring-of-flows-using-a-calorimetric-flow-switch","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/","title":{"rendered":"Economical monitoring of flows using a calorimetric flow switch"},"content":{"rendered":"<p><strong>Anyone who has dealt with the topic of flow measurement will know that a corresponding measuring instrument costs several thousand euros. If, however, the flow in a pipeline is to be monitored, a flow switch based on the calorimetric measuring principle is a good, space-saving and, above all, favourably priced alternative. So how do flow meters differ from flow switches?<\/strong><br \/>\n\u00a0<br \/>\nWherever gases or liquids are charged based on their consumption, the use of precision flow measuring instruments cannot be avoided. These determine volume or mass flows with a measuring deviation of approximately two percent or better.<\/p>\n<p><a href=\"https:\/\/www.wika.com\/en-en\/flow_switches.WIKA\" rel=\"external\" target=\"_blank\">Flow switches<\/a>, also called flow monitors, do not work by detecting flow volumes per unit of time; they are merely intended to detect the presence or absence of flow. In this context, the measuring accuracy plays a lesser role since in the first place a switching mechanism is to be initiated \u2012 meaning, on reaching a defined flow velocity, a contact switches with a non-repeatability of between two and five percent. Typically, calorimetric flow switches are used in cooling circuits, cooling lubricant systems in machine tools, in filter units or as dry run protection in pumping stations.<\/p>\n<p><strong>Note<br \/>\n<\/strong>Further information can be found on the <a href=\"https:\/\/www.wika.com\/en-en\/startpage.WIKA\" rel=\"external\" target=\"_blank\">WIKA website<\/a>. Do you need help choosing the right flow switch for your application? Your <a href=\"https:\/\/www.wika.com\/en-en\/contact.WIKA\" rel=\"external\" target=\"_blank\">contact person<\/a> will be happy to help you.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Anyone who has dealt with the topic of flow measurement will know that a corresponding measuring instrument costs several thousand euros. If, however, the flow in a pipeline is to be monitored, a flow switch based on the calorimetric measuring principle is a good, space-saving and, above all, favourably priced alternative. So how do flow [&hellip;]<\/p>\n","protected":false},"author":142,"featured_media":9576,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[224],"tags":[459,389],"class_list":["post-7984","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-products","tag-calorimetric","tag-flow-switches"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Economical monitoring of flows using a calorimetric flow switch<\/title>\n<meta name=\"description\" content=\"A flow switch based on the calorimetric measuring principle is a good, space-saving and, above all, favourably priced alternative.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Economical monitoring of flows using a calorimetric flow switch\" \/>\n<meta property=\"og:description\" content=\"A flow switch based on the calorimetric measuring principle is a good, space-saving and, above all, favourably priced alternative.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/en\/files\/2020\/01\/berwachung-mit-kalorimetrischem-str\u00f6mungsschalter-fsd-3.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Oleg Greber\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Oleg Greber\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/\"},\"author\":{\"name\":\"Oleg Greber\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/511cad680025ba53e26de8d888397730\"},\"headline\":\"Economical monitoring of flows using a calorimetric flow switch\",\"datePublished\":\"2017-09-07T07:30:47+00:00\",\"dateModified\":\"2021-08-26T06:16:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/\"},\"wordCount\":232,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2020\/01\/berwachung-mit-kalorimetrischem-str\u00f6mungsschalter-fsd-3.jpg\",\"keywords\":[\"Calorimetric\",\"Flow switches\/Flow monitors\"],\"articleSection\":[\"Flow\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/\",\"url\":\"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/\",\"name\":\"Economical monitoring of flows using a calorimetric flow switch\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2020\/01\/berwachung-mit-kalorimetrischem-str\u00f6mungsschalter-fsd-3.jpg\",\"datePublished\":\"2017-09-07T07:30:47+00:00\",\"dateModified\":\"2021-08-26T06:16:28+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/511cad680025ba53e26de8d888397730\"},\"description\":\"A flow switch based on the calorimetric measuring principle is a good, space-saving and, above all, favourably priced alternative.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2020\/01\/berwachung-mit-kalorimetrischem-str\u00f6mungsschalter-fsd-3.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2020\/01\/berwachung-mit-kalorimetrischem-str\u00f6mungsschalter-fsd-3.jpg\",\"width\":838,\"height\":471,\"caption\":\"Monitoring with a calorimetric flow switch\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.wika.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Economical monitoring of flows using a calorimetric flow switch\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/en\/#website\",\"url\":\"https:\/\/blog.wika.com\/en\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/511cad680025ba53e26de8d888397730\",\"name\":\"Oleg Greber\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/files\/2017\/08\/greberoleg-140x140.jpg\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2017\/08\/greberoleg-140x140.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2017\/08\/greberoleg-140x140.jpg\",\"caption\":\"Oleg Greber\"},\"description\":\"Seit 2015 bin ich als Produktmanager f\u00fcr die industrielle F\u00fcllstands- und Durchflussmesstechnik bei der Firma WIKA t\u00e4tig. Diese Plattform m\u00f6chte ich nutzen, um produktspezifische Fragen zu Technik, Messprinzip und Applikation aufzuarbeiten und Antworten kompakt zu erl\u00e4utern. Gleichzeitig freue ich mich sehr auf Anregungen Ihrerseits.\",\"url\":\"https:\/\/blog.wika.com\/en\/author\/grebero\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Economical monitoring of flows using a calorimetric flow switch","description":"A flow switch based on the calorimetric measuring principle is a good, space-saving and, above all, favourably priced alternative.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/","og_locale":"en_GB","og_type":"article","og_title":"Economical monitoring of flows using a calorimetric flow switch","og_description":"A flow switch based on the calorimetric measuring principle is a good, space-saving and, above all, favourably priced alternative.","og_url":"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/","og_site_name":"WIKA blog","og_image":[{"width":838,"height":471,"url":"https:\/\/blog.wika.com\/en\/files\/2020\/01\/berwachung-mit-kalorimetrischem-str\u00f6mungsschalter-fsd-3.jpg","type":"image\/jpeg"}],"author":"Oleg Greber","twitter_misc":{"Written by":"Oleg Greber","Estimated reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/"},"author":{"name":"Oleg Greber","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/511cad680025ba53e26de8d888397730"},"headline":"Economical monitoring of flows using a calorimetric flow switch","datePublished":"2017-09-07T07:30:47+00:00","dateModified":"2021-08-26T06:16:28+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/"},"wordCount":232,"commentCount":0,"image":{"@id":"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2020\/01\/berwachung-mit-kalorimetrischem-str\u00f6mungsschalter-fsd-3.jpg","keywords":["Calorimetric","Flow switches\/Flow monitors"],"articleSection":["Flow"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/","url":"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/","name":"Economical monitoring of flows using a calorimetric flow switch","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2020\/01\/berwachung-mit-kalorimetrischem-str\u00f6mungsschalter-fsd-3.jpg","datePublished":"2017-09-07T07:30:47+00:00","dateModified":"2021-08-26T06:16:28+00:00","author":{"@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/511cad680025ba53e26de8d888397730"},"description":"A flow switch based on the calorimetric measuring principle is a good, space-saving and, above all, favourably priced alternative.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/#primaryimage","url":"https:\/\/blog.wika.com\/en\/files\/2020\/01\/berwachung-mit-kalorimetrischem-str\u00f6mungsschalter-fsd-3.jpg","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2020\/01\/berwachung-mit-kalorimetrischem-str\u00f6mungsschalter-fsd-3.jpg","width":838,"height":471,"caption":"Monitoring with a calorimetric flow switch"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/en\/products\/flow-products\/economical-monitoring-of-flows-using-a-calorimetric-flow-switch\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/en\/"},{"@type":"ListItem","position":2,"name":"Economical monitoring of flows using a calorimetric flow switch"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/en\/#website","url":"https:\/\/blog.wika.com\/en\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/511cad680025ba53e26de8d888397730","name":"Oleg Greber","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/files\/2017\/08\/greberoleg-140x140.jpg","url":"https:\/\/blog.wika.com\/en\/files\/2017\/08\/greberoleg-140x140.jpg","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2017\/08\/greberoleg-140x140.jpg","caption":"Oleg Greber"},"description":"Seit 2015 bin ich als Produktmanager f\u00fcr die industrielle F\u00fcllstands- und Durchflussmesstechnik bei der Firma WIKA t\u00e4tig. Diese Plattform m\u00f6chte ich nutzen, um produktspezifische Fragen zu Technik, Messprinzip und Applikation aufzuarbeiten und Antworten kompakt zu erl\u00e4utern. Gleichzeitig freue ich mich sehr auf Anregungen Ihrerseits.","url":"https:\/\/blog.wika.com\/en\/author\/grebero\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/7984","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/users\/142"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/comments?post=7984"}],"version-history":[{"count":8,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/7984\/revisions"}],"predecessor-version":[{"id":12197,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/7984\/revisions\/12197"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media\/9576"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media?parent=7984"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/categories?post=7984"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/tags?post=7984"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}