{"id":864,"date":"2012-07-11T11:51:48","date_gmt":"2012-07-11T11:51:48","guid":{"rendered":"http:\/\/wika-blog-live.mcon.net\/?p=864"},"modified":"2022-11-28T13:58:38","modified_gmt":"2022-11-28T12:58:38","slug":"angular-connector-form-a-leaking-loss-of-ip-ingress-protection","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/","title":{"rendered":"Angular connector form A leaking\/ loss of IP ingress protection"},"content":{"rendered":"<p>What are the rules that must be observed when assembling the angular connector EN 175301-803 A, to ensure that the IP rating is maintained, that is, connector and device remain really leak-tight? Unfortunately, a lot of things can go wrong when using the angular connector EN 175301-803 A (better known as valve connector, big DIN, large Hirschmann connector or under the old name DIN 43650 connector). Unfortunately, almost all of these errors lead to the loss of the IP rating, not only for the connector, but also in most cases for the complete device! Accordingly, when using the DIN connector, be sure to avoid the following most common sources of error:<\/p>\n<ul>\n<li>Does the cable fit the specified clamping diameter of the cable gland?<\/li>\n<li>Has \u00a0the connector an integrated seal or is a separate seal properly placed between the device plug and the mating connector- and does the seal fit to the connector at all?<\/li>\n<\/ul>\n<p>Has the screw been tightened correctly and does \u00a0the screw head fit and seal correctly?<\/p>\n","protected":false},"excerpt":{"rendered":"<p>What are the rules that must be observed when assembling the angular connector EN 175301-803 A, to ensure that the IP rating is maintained, that is, connector and device remain really leak-tight? Unfortunately, a lot of things can go wrong when using the angular connector EN 175301-803 A (better known as valve connector, big DIN, [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":675,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[267,45],"class_list":["post-864","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general","tag-electrical-connection","tag-ingress-protection"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Use of the angular connector EN 175301-803 A - WIKA blog<\/title>\n<meta name=\"description\" content=\"This blog article explains the rules that must be observed when assembling the angular connector EN 175301-803 A, to ensure that the IP rating is maintained.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Use of the angular connector EN 175301-803 A - WIKA blog\" \/>\n<meta property=\"og:description\" content=\"This blog article explains the rules that must be observed when assembling the angular connector EN 175301-803 A, to ensure that the IP rating is maintained.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/en\/files\/2012\/07\/bid_DIN.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2089\" \/>\n\t<meta property=\"og:image:height\" content=\"1525\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Mich\u00e8le Beyer\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Mich\u00e8le Beyer\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/\"},\"author\":{\"name\":\"Mich\u00e8le Beyer\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/13ca97d373c6de6a796587c8d415527a\"},\"headline\":\"Angular connector form A leaking\/ loss of IP ingress protection\",\"datePublished\":\"2012-07-11T11:51:48+00:00\",\"dateModified\":\"2022-11-28T12:58:38+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/\"},\"wordCount\":178,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2012\/07\/bid_DIN.jpg\",\"keywords\":[\"Electrical connection\",\"Ingress protection\"],\"articleSection\":[\"General\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/\",\"url\":\"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/\",\"name\":\"Use of the angular connector EN 175301-803 A - WIKA blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/en\/files\/2012\/07\/bid_DIN.jpg\",\"datePublished\":\"2012-07-11T11:51:48+00:00\",\"dateModified\":\"2022-11-28T12:58:38+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/13ca97d373c6de6a796587c8d415527a\"},\"description\":\"This blog article explains the rules that must be observed when assembling the angular connector EN 175301-803 A, to ensure that the IP rating is maintained.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2012\/07\/bid_DIN.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2012\/07\/bid_DIN.jpg\",\"width\":2089,\"height\":1525,\"caption\":\"assembly of an angular connector\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.wika.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Angular connector form A leaking\/ loss of IP ingress protection\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/en\/#website\",\"url\":\"https:\/\/blog.wika.com\/en\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/en\/#\/schema\/person\/13ca97d373c6de6a796587c8d415527a\",\"name\":\"Mich\u00e8le Beyer\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/blog.wika.com\/en\/files\/2017\/05\/beyer-michele-140x140.jpg\",\"url\":\"https:\/\/blog.wika.com\/en\/files\/2017\/05\/beyer-michele-140x140.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/en\/files\/2017\/05\/beyer-michele-140x140.jpg\",\"caption\":\"Mich\u00e8le Beyer\"},\"description\":\"I joined WIKA in 1998 and have been working from the start in product management. Every day I answer a wide range of questions on the topic of electronic pressure measurement. Many questions are asked over and over again by WIKA staff and customers from all over the world. So why not answer the most interesting questions in this blog?\",\"url\":\"https:\/\/blog.wika.com\/en\/author\/bemi73\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Use of the angular connector EN 175301-803 A - WIKA blog","description":"This blog article explains the rules that must be observed when assembling the angular connector EN 175301-803 A, to ensure that the IP rating is maintained.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/","og_locale":"en_GB","og_type":"article","og_title":"Use of the angular connector EN 175301-803 A - WIKA blog","og_description":"This blog article explains the rules that must be observed when assembling the angular connector EN 175301-803 A, to ensure that the IP rating is maintained.","og_url":"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/","og_site_name":"WIKA blog","og_image":[{"width":2089,"height":1525,"url":"https:\/\/blog.wika.com\/en\/files\/2012\/07\/bid_DIN.jpg","type":"image\/jpeg"}],"author":"Mich\u00e8le Beyer","twitter_misc":{"Written by":"Mich\u00e8le Beyer","Estimated reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/"},"author":{"name":"Mich\u00e8le Beyer","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/13ca97d373c6de6a796587c8d415527a"},"headline":"Angular connector form A leaking\/ loss of IP ingress protection","datePublished":"2012-07-11T11:51:48+00:00","dateModified":"2022-11-28T12:58:38+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/"},"wordCount":178,"image":{"@id":"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2012\/07\/bid_DIN.jpg","keywords":["Electrical connection","Ingress protection"],"articleSection":["General"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/","url":"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/","name":"Use of the angular connector EN 175301-803 A - WIKA blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/en\/files\/2012\/07\/bid_DIN.jpg","datePublished":"2012-07-11T11:51:48+00:00","dateModified":"2022-11-28T12:58:38+00:00","author":{"@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/13ca97d373c6de6a796587c8d415527a"},"description":"This blog article explains the rules that must be observed when assembling the angular connector EN 175301-803 A, to ensure that the IP rating is maintained.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/#primaryimage","url":"https:\/\/blog.wika.com\/en\/files\/2012\/07\/bid_DIN.jpg","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2012\/07\/bid_DIN.jpg","width":2089,"height":1525,"caption":"assembly of an angular connector"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/en\/general\/angular-connector-form-a-leaking-loss-of-ip-ingress-protection\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/en\/"},{"@type":"ListItem","position":2,"name":"Angular connector form A leaking\/ loss of IP ingress protection"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/en\/#website","url":"https:\/\/blog.wika.com\/en\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, force, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/en\/#\/schema\/person\/13ca97d373c6de6a796587c8d415527a","name":"Mich\u00e8le Beyer","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/blog.wika.com\/en\/files\/2017\/05\/beyer-michele-140x140.jpg","url":"https:\/\/blog.wika.com\/en\/files\/2017\/05\/beyer-michele-140x140.jpg","contentUrl":"https:\/\/blog.wika.com\/en\/files\/2017\/05\/beyer-michele-140x140.jpg","caption":"Mich\u00e8le Beyer"},"description":"I joined WIKA in 1998 and have been working from the start in product management. Every day I answer a wide range of questions on the topic of electronic pressure measurement. Many questions are asked over and over again by WIKA staff and customers from all over the world. So why not answer the most interesting questions in this blog?","url":"https:\/\/blog.wika.com\/en\/author\/bemi73\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/864","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/comments?post=864"}],"version-history":[{"count":8,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/864\/revisions"}],"predecessor-version":[{"id":12562,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/posts\/864\/revisions\/12562"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media\/675"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/media?parent=864"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/categories?post=864"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/en\/wp-json\/wp\/v2\/tags?post=864"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}