{"id":11735,"date":"2024-03-04T08:00:15","date_gmt":"2024-03-04T07:00:15","guid":{"rendered":"https:\/\/blog.wika.com\/fr\/?p=11735"},"modified":"2024-03-01T17:16:24","modified_gmt":"2024-03-01T16:16:24","slug":"mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/","title":{"rendered":"Mesure de temp\u00e9rature Tubeskin : am\u00e9liorer la pr\u00e9cision du thermocouple Tubeskin sur une platine de raccordement interm\u00e9diaire"},"content":{"rendered":"<p><strong>WIKA a effectu\u00e9 une s\u00e9rie de tests &#8211; sur le terrain et \u00e0 l&rsquo;aide de la dynamique des fluides num\u00e9rique &#8211; pour \u00e9valuer la pr\u00e9cision des thermocouples Tubeskin (TSTC) lorsqu&rsquo;ils sont install\u00e9s sur une platine de raccordement par rapport \u00e0 un tube nu. Nous avons \u00e9galement fait varier l&rsquo;orientation du mat\u00e9riau de soudure (transversale ou longitudinale), ses valeurs d&rsquo;\u00e9missivit\u00e9 (\u03b5 = 0,45, 0,67 et 0,85) et soumis les sondes \u00e0 diff\u00e9rentes conditions de fonctionnement (cuisson \u00e0 6,9 MMBtu\/hr et 12,7 MMBtu\/hr).<\/strong><\/p>\n<p>\nSur la base de ces donn\u00e9es, nous sommes parvenus \u00e0 plusieurs conclusions ainsi qu&rsquo;\u00e0 deux moyens d&rsquo;am\u00e9liorer la pr\u00e9cision des TSTC lorsque les capteurs ne sont pas install\u00e9s directement sur un tube de four nu.<\/p>\n<h2>\nL&rsquo;impact des platines de raccordement sur la pr\u00e9cision des thermocouples Tubeskin : Observations et moyens d&rsquo;am\u00e9liorer la pr\u00e9cision<\/h2>\n<p>Les donn\u00e9es recueillies nous permettent de faire les observations suivantes :<\/p>\n<ul>\n<li>La finition de la surface de la platine de raccordement a un impact certain sur la distribution de la temp\u00e9rature et, par cons\u00e9quent, sur la pr\u00e9cision du thermocouple qui y est mont\u00e9. L&rsquo;augmentation de la valeur d&rsquo;\u00e9missivit\u00e9 de la platine de raccordement \u00b2de 0,67 \u00e0 0,85 a fait varier sa temp\u00e9rature de surface de 6\u00b0C et a augment\u00e9 son \u00e9cart de temp\u00e9rature (par rapport au tube nu) de 6\u00b0C (<a href=\"https:\/\/blog.wika.com\/fr\/general\/precision-du-thermocouple-tubeskin\/\">voir tableau 2<\/a>).<\/li>\n<li>Quelle que soit la valeur d&rsquo;\u00e9missivit\u00e9 de la platine de raccordement, le produit install\u00e9 sur une platine de raccordement donne des valeurs plus \u00e9lev\u00e9es que lorsqu&rsquo;il est install\u00e9 sur un tube nu. L&rsquo;ampleur de l&rsquo;\u00e9cart par rapport \u00e0 la valeur r\u00e9elle est sp\u00e9cifique au produit.<\/li>\n<li>Sur un tube nu, le produit blind\u00e9 semble avoir un \u00e9cart de temp\u00e9rature plus \u00e9lev\u00e9 que la version non blind\u00e9e \u00e0 un niveau d&rsquo;utilisation \u00e9lev\u00e9 (<a href=\"https:\/\/blog.wika.com\/fr\/general\/precision-du-thermocouple-tubeskin\/\">voir tableau 4<\/a>). Il est \u00e0 noter que les produits blind\u00e9s, dont la temp\u00e9rature est l\u00e9g\u00e8rement inf\u00e9rieure \u00e0 la temp\u00e9rature r\u00e9elle du Tubeskin, peuvent maintenant potentiellement donner de meilleurs r\u00e9sultats lorsqu&rsquo;ils sont install\u00e9s sur la platine de raccordement.<\/li>\n<li>Nous pouvons en d\u00e9duire que les produits TSTC con\u00e7us pour une lecture pr\u00e9cise sur des tubes nus afficheront une temp\u00e9rature plus \u00e9lev\u00e9e lorsqu&rsquo;ils sont install\u00e9s sur une platine de raccordement interm\u00e9diaire, et que l&rsquo;ampleur de l&rsquo;\u00e9cart de temp\u00e9rature sera d\u00e9termin\u00e9e par l&rsquo;\u00e9missivit\u00e9, la dimension et la conductivit\u00e9 thermique de la platine de raccordement.<\/li>\n<\/ul>\n<p>\nNous avons formul\u00e9 deux hypoth\u00e8ses pour am\u00e9liorer les performances du produit lorsqu&rsquo;il est install\u00e9 sur une platine de raccordement :<\/p>\n<ul>\n<li>Faire varier la conductivit\u00e9 thermique de la platine de raccordement en utilisant diff\u00e9rents mat\u00e9riaux de soudure.<\/li>\n<li>R\u00e9duire l&rsquo;\u00e9missivit\u00e9 de la platine de raccordement par la pr\u00e9paration de la surface.<\/li>\n<\/ul>\n<p>Pour la simulation CFD suivante, nous avons :<\/p>\n<ul>\n<li>augment\u00e9 la conductivit\u00e9 thermique de la platine de raccordement de 20 %.<\/li>\n<li>r\u00e9duit la valeur d&rsquo;\u00e9missivit\u00e9 de 0,67 \u00e0 0,45.<\/li>\n<\/ul>\n<p>\nLe produit TSTC et les dimensions de la platine de raccordement restent inchang\u00e9s.<\/p>\n<p>\nNous avons constat\u00e9 que l&rsquo;augmentation de la conductivit\u00e9 thermique de la platine de raccordement et la diminution de son \u00e9missivit\u00e9 se traduisaient par une am\u00e9lioration significative de la pr\u00e9cision du produit non blind\u00e9 (voir tableau 6), de 6\u00b0C \u00e0 15\u00b0C (\u2206 9\u00b0C) et de +3\u00b0C \u00e0 16\u00b0C (\u2206 13\u00b0C). Pour le produit blind\u00e9, l&rsquo;am\u00e9lioration \u00e9tait de 5\u00b0C \u00e0 7\u00b0C (\u2206 2\u00b0C) et de 6\u00b0C \u00e0 8\u00b0C (\u2206 2\u00b0C).<\/p>\n<p>\n<strong>Tableau 6 : \u00c9cart de temp\u00e9rature du TSTC non blind\u00e9 par rapport au TSTC non blind\u00e9 sur la platine de raccordement \u03b5 = 0,45 et condition thermique = 1,2, simulation CFD<\/strong><\/p>\n<table style=\"border-collapse: collapse;width: 100%\">\n<tbody>\n<tr>\n<td style=\"width: 16.6667%\">N\u00b0<\/td>\n<td style=\"width: 16.6667%\">Chauffe (MMBtu\/hr)<\/td>\n<td style=\"width: 16.6667%\">Temp\u00e9rature tube nu*<\/td>\n<td style=\"width: 16.6667%\">\u00a0<\/td>\n<td style=\"width: 16.6667%\">Lecture de la temp\u00e9rature*<\/td>\n<td style=\"width: 16.6667%\">Ecart de temp\u00e9rature*<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 16.6667%\">1<\/td>\n<td style=\"width: 16.6667%\">6,9<\/td>\n<td style=\"width: 16.6667%\">425\u00b0C<\/td>\n<td style=\"width: 16.6667%\">\n<table style=\"border-collapse: collapse;width: 100%\">\n<tbody>\n<tr>\n<td style=\"width: 100%\"><span>TSTC non blind\u00e9<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 100%\"><span>TSTC blind\u00e9<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td style=\"width: 16.6667%\">\n<table style=\"border-collapse: collapse;width: 100%\">\n<tbody>\n<tr>\n<td style=\"width: 100%\">428\u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 100%\">435\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td style=\"width: 16.6667%\">\n<table style=\"border-collapse: collapse;width: 100%\">\n<tbody>\n<tr>\n<td style=\"width: 100%\">-15\u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 100%\">-7\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 16.6667%\">2<\/td>\n<td style=\"width: 16.6667%\">12,7<\/td>\n<td style=\"width: 16.6667%\">539\u00b0C<\/td>\n<td style=\"width: 16.6667%\">\n<table style=\"border-collapse: collapse;width: 100%\">\n<tbody>\n<tr>\n<td style=\"width: 100%\"><span>TSTC non blind\u00e9<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 100%\"><span>TSTC blind\u00e9<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td style=\"width: 16.6667%\">\n<table style=\"border-collapse: collapse;width: 100%\">\n<tbody>\n<tr>\n<td style=\"width: 100%\">539\u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 100%\">548\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td style=\"width: 16.6667%\">\n<table style=\"border-collapse: collapse;width: 100%\">\n<tbody>\n<tr>\n<td style=\"width: 100%\">-16\u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 100%\">-9\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* Les valeurs sont arrondies<\/p>\n<h2>Conclusions et prochaines \u00e9tapes<\/h2>\n<p>\nL&rsquo;installation d&rsquo;un thermocouple sur une platine de raccordement interm\u00e9diaire est une bonne id\u00e9e pour des raisons m\u00e9tallurgiques, mais elle s&rsquo;accompagne d&rsquo;une p\u00e9nalit\u00e9 en termes de pr\u00e9cision. Cela dit, les produits dont la temp\u00e9rature est normalement inf\u00e9rieure \u00e0 la temp\u00e9rature r\u00e9elle seront plus \u00e9lev\u00e9s qu&rsquo;auparavant sur une platine de raccordement ; selon la conception du produit, ils peuvent m\u00eame se rapprocher de la temp\u00e9rature r\u00e9elle ou \u00eatre plus \u00e9lev\u00e9s que celle-ci. De m\u00eame, pour les produits qui donnent des mesures plus hautes que la temp\u00e9rature r\u00e9elle, l&rsquo;\u00e9cart de temp\u00e9rature est encore plus grand lorsque le thermocouple est install\u00e9 sur une platine de raccordement.<\/p>\n<p>\nLa variation des propri\u00e9t\u00e9s physiques de la platine de raccordement, telles que l&rsquo;\u00e9missivit\u00e9 et le mat\u00e9riau de recouvrement, peut am\u00e9liorer la pr\u00e9cision d&rsquo;un TSTC. Toutefois, l&rsquo;efficacit\u00e9 de ces mesures est propre au produit install\u00e9 ; des essais et des analyses CFD seraient n\u00e9cessaires pour parvenir \u00e0 une solution optimale.<\/p>\n<p>\nLe but ultime, bien s\u00fbr, est d&rsquo;utiliser les informations et les enseignements de ce projet pour guider les clients dans la conception de solutions de mesure de la temp\u00e9rature pour leurs chauffages sp\u00e9cifiques \u00e0 combustion, leurs conditions de fonctionnement, leurs tubes de four et leurs thermocouples Tubeskin.<\/p>\n<p>&nbsp;<\/p>\n<h2>WIKA, expert dans la mesure de temp\u00e9rature avec des thermocouples Tubeskin<\/h2>\n<p>\nWIKA est un leader mondial des solutions de mesure de temp\u00e9rature pour les applications en aval dans <a href=\"https:\/\/www.wika.com\/fr-fr\/industrie_du_petrole_et_du_gaz_up_mid_et_downstream.WIKA\" rel=\"external\" target=\"_blank\">l&rsquo;industrie du p\u00e9trole et du gaz<\/a>. Outre la fabrication et la personnalisation de<a href=\"https:\/\/www.wika.com\/fr-fr\/thermocouples_tubeskin.WIKA\" rel=\"external\" target=\"_blank\"> thermocouples de peau<\/a> et de <a href=\"https:\/\/www.wika.com\/fr-fr\/thermocouples_tubeskin.WIKA\" rel=\"external\" target=\"_blank\">thermocouples multipoints<\/a> de haute qualit\u00e9 pour les unit\u00e9s de raffinage, nous proposons plusieurs services destin\u00e9s \u00e0 am\u00e9liorer les op\u00e9rations d&rsquo;une usine :<\/p>\n<ul>\n<li><a href=\"https:\/\/www.wika.com\/fr-fr\/service_sur_site.WIKA\" rel=\"external\" target=\"_blank\">Installation de thermocouples<\/a>, y compris la supervision, les travaux de soudure, le d\u00e9pannage et les inspections.<\/li>\n<li><a href=\"https:\/\/www.wika.com\/fr-fr\/service_sur_site.WIKA\" rel=\"external\" target=\"_blank\">V\u00e9rification des thermocouples<\/a> pendant les arr\u00eats de production<\/li>\n<li>Remplacement des thermocouples<\/li>\n<\/ul>\n<p>\n<a href=\"https:\/\/www.wika.com\/fr-fr\/contact.WIKA\" rel=\"external\" target=\"_blank\">Contactez-nous<\/a> pour plus d&rsquo;informations sur la fa\u00e7on dont WIKA peut augmenter la s\u00e9curit\u00e9 et la rentabilit\u00e9 de votre installation.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>WIKA a effectu\u00e9 une s\u00e9rie de tests &#8211; sur le terrain et \u00e0 l&rsquo;aide de la dynamique des fluides num\u00e9rique &#8211; pour \u00e9valuer la pr\u00e9cision des thermocouples Tubeskin (TSTC) lorsqu&rsquo;ils sont install\u00e9s sur une platine de raccordement par rapport \u00e0 un tube nu. Nous avons \u00e9galement fait varier l&rsquo;orientation du mat\u00e9riau de soudure (transversale ou [&hellip;]<\/p>\n","protected":false},"author":126,"featured_media":11730,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[405,15,534,402],"class_list":["post-11735","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general","tag-mesure-de-la-temprature","tag-precision","tag-sonde-de-peau","tag-thermocouple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Am\u00e9liorer la pr\u00e9cision du thermocouple Tubeskin - Blog WIKA<\/title>\n<meta name=\"description\" content=\"Nous avons effectu\u00e9 des tests pour \u00e9valuer la pr\u00e9cision des thermocouples Tubeskin install\u00e9s sur une platine de raccordement par rapport \u00e0 un tube nu.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Am\u00e9liorer la pr\u00e9cision du thermocouple Tubeskin - Blog WIKA\" \/>\n<meta property=\"og:description\" content=\"Nous avons effectu\u00e9 des tests pour \u00e9valuer la pr\u00e9cision des thermocouples Tubeskin install\u00e9s sur une platine de raccordement par rapport \u00e0 un tube nu.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/\" \/>\n<meta property=\"og:site_name\" content=\"Blog WIKA\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/fr\/files\/2024\/03\/24-10-ir-scan-furnace-tubes.png\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Pierre Forestier\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Pierre Forestier\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/\"},\"author\":{\"name\":\"Pierre Forestier\",\"@id\":\"https:\/\/blog.wika.com\/fr\/#\/schema\/person\/6c7424b4c91008e8a02c85213a8bbe64\"},\"headline\":\"Mesure de temp\u00e9rature Tubeskin : am\u00e9liorer la pr\u00e9cision du thermocouple Tubeskin sur une platine de raccordement interm\u00e9diaire\",\"datePublished\":\"2024-03-04T07:00:15+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/\"},\"wordCount\":1029,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/#organization\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/fr\/files\/2024\/03\/24-10-ir-scan-furnace-tubes.png\",\"keywords\":[\"mesure de la temp\u00e9rature\",\"Pr\u00e9cision\",\"sonde de peau\",\"thermocouple\"],\"articleSection\":[\"G\u00e9n\u00e9ral\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/\",\"url\":\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/\",\"name\":\"Am\u00e9liorer la pr\u00e9cision du thermocouple Tubeskin - Blog WIKA\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/fr\/files\/2024\/03\/24-10-ir-scan-furnace-tubes.png\",\"datePublished\":\"2024-03-04T07:00:15+00:00\",\"description\":\"Nous avons effectu\u00e9 des tests pour \u00e9valuer la pr\u00e9cision des thermocouples Tubeskin install\u00e9s sur une platine de raccordement par rapport \u00e0 un tube nu.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/fr\/files\/2024\/03\/24-10-ir-scan-furnace-tubes.png\",\"contentUrl\":\"https:\/\/blog.wika.com\/fr\/files\/2024\/03\/24-10-ir-scan-furnace-tubes.png\",\"width\":838,\"height\":471},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/blog.wika.com\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Mesure de temp\u00e9rature Tubeskin : am\u00e9liorer la pr\u00e9cision du thermocouple Tubeskin sur une platine de raccordement interm\u00e9diaire\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/fr\/#website\",\"url\":\"https:\/\/blog.wika.com\/fr\/\",\"name\":\"Blog WIKA\",\"description\":\"Notre blog vous propose de nombreux articles int\u00e9ressants sur la mesure de pression, temp\u00e9rature, niveau, d\u00e9bit et calibration et donne un aper\u00e7u du Groupe WIKA\",\"publisher\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/blog.wika.com\/fr\/#organization\",\"name\":\"WIKA Instruments\",\"url\":\"https:\/\/blog.wika.com\/fr\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/blog.wika.com\/fr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/blog.wika.com\/fr\/files\/2016\/02\/logo_wika_cmyk.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/fr\/files\/2016\/02\/logo_wika_cmyk.jpg\",\"width\":758,\"height\":263,\"caption\":\"WIKA Instruments\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/fr\/#\/schema\/person\/6c7424b4c91008e8a02c85213a8bbe64\",\"name\":\"Pierre Forestier\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/blog.wika.com\/fr\/files\/2023\/06\/pierre-blog-120x120.jpg\",\"url\":\"https:\/\/blog.wika.com\/fr\/files\/2023\/06\/pierre-blog-120x120.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/fr\/files\/2023\/06\/pierre-blog-120x120.jpg\",\"caption\":\"Pierre Forestier\"},\"description\":\"Chez WIKA France depuis 1998, j\u2019ai entre autres la responsabilit\u00e9 des instruments de mesure de pression et de temp\u00e9rature m\u00e9caniques. Cette longue exp\u00e9rience m\u2019a permis de cotoyer de tr\u00e8s nombreuses applications et probl\u00e9matiques d\u2019instrumentation. Je pourrais ainsi r\u00e9pondre \u00e0 vos questions sur des cas concrets d\u2019utilisation de nos instruments.\",\"url\":\"https:\/\/blog.wika.com\/fr\/author\/forestp\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Am\u00e9liorer la pr\u00e9cision du thermocouple Tubeskin - Blog WIKA","description":"Nous avons effectu\u00e9 des tests pour \u00e9valuer la pr\u00e9cision des thermocouples Tubeskin install\u00e9s sur une platine de raccordement par rapport \u00e0 un tube nu.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/","og_locale":"fr_FR","og_type":"article","og_title":"Am\u00e9liorer la pr\u00e9cision du thermocouple Tubeskin - Blog WIKA","og_description":"Nous avons effectu\u00e9 des tests pour \u00e9valuer la pr\u00e9cision des thermocouples Tubeskin install\u00e9s sur une platine de raccordement par rapport \u00e0 un tube nu.","og_url":"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/","og_site_name":"Blog WIKA","og_image":[{"width":838,"height":471,"url":"https:\/\/blog.wika.com\/fr\/files\/2024\/03\/24-10-ir-scan-furnace-tubes.png","type":"image\/png"}],"author":"Pierre Forestier","twitter_misc":{"\u00c9crit par":"Pierre Forestier","Dur\u00e9e de lecture estim\u00e9e":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/"},"author":{"name":"Pierre Forestier","@id":"https:\/\/blog.wika.com\/fr\/#\/schema\/person\/6c7424b4c91008e8a02c85213a8bbe64"},"headline":"Mesure de temp\u00e9rature Tubeskin : am\u00e9liorer la pr\u00e9cision du thermocouple Tubeskin sur une platine de raccordement interm\u00e9diaire","datePublished":"2024-03-04T07:00:15+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/"},"wordCount":1029,"commentCount":0,"publisher":{"@id":"https:\/\/blog.wika.com\/fr\/#organization"},"image":{"@id":"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/fr\/files\/2024\/03\/24-10-ir-scan-furnace-tubes.png","keywords":["mesure de la temp\u00e9rature","Pr\u00e9cision","sonde de peau","thermocouple"],"articleSection":["G\u00e9n\u00e9ral"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/","url":"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/","name":"Am\u00e9liorer la pr\u00e9cision du thermocouple Tubeskin - Blog WIKA","isPartOf":{"@id":"https:\/\/blog.wika.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/fr\/files\/2024\/03\/24-10-ir-scan-furnace-tubes.png","datePublished":"2024-03-04T07:00:15+00:00","description":"Nous avons effectu\u00e9 des tests pour \u00e9valuer la pr\u00e9cision des thermocouples Tubeskin install\u00e9s sur une platine de raccordement par rapport \u00e0 un tube nu.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#primaryimage","url":"https:\/\/blog.wika.com\/fr\/files\/2024\/03\/24-10-ir-scan-furnace-tubes.png","contentUrl":"https:\/\/blog.wika.com\/fr\/files\/2024\/03\/24-10-ir-scan-furnace-tubes.png","width":838,"height":471},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/fr\/general\/mesure-de-temperature-tubeskin-ameliorer-la-precision-du-thermocouple-tubeskin-sur-une-platine-de-raccordement-intermdiaire\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/blog.wika.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Mesure de temp\u00e9rature Tubeskin : am\u00e9liorer la pr\u00e9cision du thermocouple Tubeskin sur une platine de raccordement interm\u00e9diaire"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/fr\/#website","url":"https:\/\/blog.wika.com\/fr\/","name":"Blog WIKA","description":"Notre blog vous propose de nombreux articles int\u00e9ressants sur la mesure de pression, temp\u00e9rature, niveau, d\u00e9bit et calibration et donne un aper\u00e7u du Groupe WIKA","publisher":{"@id":"https:\/\/blog.wika.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/blog.wika.com\/fr\/#organization","name":"WIKA Instruments","url":"https:\/\/blog.wika.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/blog.wika.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/blog.wika.com\/fr\/files\/2016\/02\/logo_wika_cmyk.jpg","contentUrl":"https:\/\/blog.wika.com\/fr\/files\/2016\/02\/logo_wika_cmyk.jpg","width":758,"height":263,"caption":"WIKA Instruments"},"image":{"@id":"https:\/\/blog.wika.com\/fr\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/blog.wika.com\/fr\/#\/schema\/person\/6c7424b4c91008e8a02c85213a8bbe64","name":"Pierre Forestier","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/blog.wika.com\/fr\/files\/2023\/06\/pierre-blog-120x120.jpg","url":"https:\/\/blog.wika.com\/fr\/files\/2023\/06\/pierre-blog-120x120.jpg","contentUrl":"https:\/\/blog.wika.com\/fr\/files\/2023\/06\/pierre-blog-120x120.jpg","caption":"Pierre Forestier"},"description":"Chez WIKA France depuis 1998, j\u2019ai entre autres la responsabilit\u00e9 des instruments de mesure de pression et de temp\u00e9rature m\u00e9caniques. Cette longue exp\u00e9rience m\u2019a permis de cotoyer de tr\u00e8s nombreuses applications et probl\u00e9matiques d\u2019instrumentation. Je pourrais ainsi r\u00e9pondre \u00e0 vos questions sur des cas concrets d\u2019utilisation de nos instruments.","url":"https:\/\/blog.wika.com\/fr\/author\/forestp\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/posts\/11735","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/users\/126"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/comments?post=11735"}],"version-history":[{"count":5,"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/posts\/11735\/revisions"}],"predecessor-version":[{"id":11740,"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/posts\/11735\/revisions\/11740"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/media\/11730"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/media?parent=11735"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/categories?post=11735"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/tags?post=11735"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}