{"id":8927,"date":"2020-10-05T08:38:17","date_gmt":"2020-10-05T06:38:17","guid":{"rendered":"https:\/\/blog.wika.com\/fr\/?p=8927"},"modified":"2020-09-25T09:56:33","modified_gmt":"2020-09-25T07:56:33","slug":"etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/","title":{"rendered":"Etalonnage en zone class\u00e9e ATEX gr\u00e2ce \u00e0 nos calibrateurs de process multifonction"},"content":{"rendered":"<p><strong>L&rsquo;\u00e9talonnage des transmetteurs de pression \u00e0 s\u00e9curit\u00e9 intrins\u00e8que sur site n\u00e9cessite un \u00e9quipement approuv\u00e9 pour une utilisation dans des zones class\u00e9es, car les instruments conventionnels ne peuvent garantir une protection ad\u00e9quate. C&rsquo;est pourquoi WIKA a mis au point une nouvelle g\u00e9n\u00e9ration de calibrateurs multifonction portables, certifi\u00e9e pour les essais dans les environnements \u00e0 risque d&rsquo;explosion (ATEX).<\/strong><\/p>\n<p>Les notions de s\u00e9curit\u00e9 et d&rsquo;efficacit\u00e9 sont indissociables dans les process de l&rsquo;industrie chimique. C&rsquo;est pourquoi les fonctions de contr\u00f4le des process sont presque toujours bas\u00e9es sur des instruments de mesure \u00e9lectroniques tels que les transmetteurs de pression. L&rsquo;instrument de contr\u00f4le doit \u00eatre r\u00e9guli\u00e8rement \u00e9talonn\u00e9 afin de d\u00e9terminer s&rsquo;il remplit sa fonction correctement et avec la pr\u00e9cision requise. Toutefois, m\u00eame dans les cas o\u00f9 l&rsquo;instrument de contr\u00f4le n&rsquo;est pas tenu de respecter les exigences du service d&rsquo;accr\u00e9ditation allemand (Dakks), les process d&rsquo;\u00e9talonnage peuvent souvent prendre beaucoup de temps.\u00a0 La r\u00e9alisation d&rsquo;inspections dans un laboratoire externe implique des temps d&rsquo;arr\u00eat encore plus importants car les instruments doivent \u00eatre envoy\u00e9s au laboratoire.<\/p>\n<p>C&rsquo;est pourquoi de nombreuses entreprises optent d\u00e9sormais pour un \u00e9talonnage sur site. Une entreprise allemande a r\u00e9cemment adopt\u00e9 cette solution pour les unit\u00e9s de production de son d\u00e9partement agricole. L&rsquo;installation, dont les secteurs peuvent \u00eatre interconnect\u00e9s de mani\u00e8re flexible en fonction du d\u00e9roulement du process, est entre autres \u00e9quip\u00e9e de plus de 200 transmetteurs de pression. Comme l&rsquo;op\u00e9rateur l&rsquo;alimente avec diff\u00e9rents fluides qui changent fr\u00e9quemment, les instruments de mesure de pression doivent \u00eatre r\u00e9guli\u00e8rement \u00e9talonn\u00e9s. Ces contr\u00f4les sont effectu\u00e9s avant et apr\u00e8s chaque op\u00e9ration. En comparant les param\u00e8tres cl\u00e9s, il est possible de v\u00e9rifier la qualit\u00e9 de la mesure tout au long du cycle. Si un process de production est prolong\u00e9 sur une longue p\u00e9riode, les \u00e9metteurs sont calibr\u00e9s les uns par rapport aux autres pour v\u00e9rifier leur fonctionnement.<\/p>\n<p>Un grand nombre d&rsquo;\u00e9quipement est g\u00e9n\u00e9ralement n\u00e9cessaire pour effectuer un \u00e9talonnage conventionnel sur place. En plus du calibrateur, il faut un moyen de g\u00e9n\u00e9rer la pression et, dans le cas des transmetteurs, une source d&rsquo;\u00e9nergie. La manipulation d&rsquo;un si grand nombre d&rsquo;appareils, outre le fait qu&rsquo;elle soit compliqu\u00e9e, demande du temps et g\u00e9n\u00e8re de nombreuses inconnues en raison des nombreuses activit\u00e9s manuelles qui doivent \u00eatre effectu\u00e9es.<\/p>\n<h2>\u00c9talonnage sur site avec un calibrateur multifonction portable<\/h2>\n\n      <div class=\"wp-caption alignright\" style=\"max-width:238px;\"><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/fr\/files\/2020\/09\/caibrador-portatil-wika-\u00e1reas-clasificadas-230x471-230x471.png\" \/><p class=\"wp-caption-text\">Appareil d&rsquo;\u00e9talonnage portable pour zones class\u00e9es, mod\u00e8le CPH7000Ex<\/p><\/div>\n    \n<p>Au vu de cette situation, l&rsquo;entreprise mentionn\u00e9e ci-dessus a d\u00e9cid\u00e9 de v\u00e9rifier les transmetteurs de pression \u00e0 l&rsquo;aide du calibrateur portable multifonction CPH7000 de WIKA, qui r\u00e9unit en un seul instrument l&rsquo;\u00e9quipement n\u00e9cessaire pour effectuer le contr\u00f4le sur site. Outre une r\u00e9f\u00e9rence de haute pr\u00e9cision (0,025% FS), il est dot\u00e9 d&rsquo;une tension \u00e9lectrique et d&rsquo;un module d&rsquo;alimentation, de sorte que les valeurs peuvent \u00eatre lues automatiquement, ainsi que d&rsquo;une pompe de g\u00e9n\u00e9ration de pression m\u00e9canique.<\/p>\n<p>La version du calibrateur \u00e0 s\u00e9curit\u00e9 intrins\u00e8que requise pour cette application est homologu\u00e9e ATEX (classification Ex ib IIC T4 Gb). Cela exclut tout risque d&rsquo;explosion, que la temp\u00e9rature d&rsquo;allumage soit atteinte en raison de la surchauffe d&rsquo;une surface, que l&rsquo;\u00e9tincelle d&rsquo;allumage soit caus\u00e9e par une charge statique dans le bo\u00eetier ou qu&rsquo;une d\u00e9faillance se produise pendant le fonctionnement \u00e9lectrique.<\/p>\n<p>Pour obtenir l&rsquo;approbation, une conception beaucoup plus complexe a \u00e9t\u00e9 n\u00e9cessaire par rapport aux manom\u00e8tres manuels, surtout en ce qui concerne la batterie. La capacit\u00e9 de la \u00ab\u00a0centrale \u00e9lectrique\u00a0\u00bb du CPH7000 doit \u00eatre compatible avec la multifonctionnalit\u00e9 de l&rsquo;instrument et permettre au moins huit heures de fonctionnement. La pile au lithium-ion est sp\u00e9cialement fusionn\u00e9e dans un couvercle de protection, qui emp\u00eache la surchauffe en cas de court-circuit ou autre d\u00e9faillance, de sorte que les \u00e9l\u00e9ments de la pile ne sont ni d\u00e9truits, ni perc\u00e9s.<\/p>\n<p>Il dispose d&rsquo;une fonction d&rsquo;arr\u00eat d&rsquo;urgence en cas d&rsquo;augmentation excessive de la puissance. En aucun cas, la batterie ne fournit plus que le courant maximal de 24 mA et la tension maximale de 30 V qui sont \u00e9mis par le module \u00e9lectronique int\u00e9gr\u00e9. Une fonction d&rsquo;arr\u00eat de s\u00e9curit\u00e9 a \u00e9t\u00e9 install\u00e9e comme condition pour recevoir l&rsquo;approbation ATEX.<\/p>\n\n      <div class=\"wp-caption aligncenter\" style=\"max-width:846px;\"><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/fr\/files\/2020\/09\/calibracion-in-situ-portatil-wika-838x471-388x218.jpg\" \/><p class=\"wp-caption-text\">L&rsquo;industrie p\u00e9trochimique. Les \u00e9talonnages \u00e0 intervalles r\u00e9guliers sont essentiels pour garantir la s\u00e9curit\u00e9 et la productivit\u00e9 des process.<\/p><\/div>\n    \n<p>&nbsp;<\/p>\n<p>La pression d&rsquo;essai requise pour l&rsquo;\u00e9talonnage ne peut \u00eatre produite qu&rsquo;\u00e0 l&rsquo;aide d&rsquo;une pompe manuelle, car les alternatives \u00e9lectriques ne r\u00e9pondraient pas aux exigences ATEX en mati\u00e8re de protection contre les explosions. Deux autres raisons ont motiv\u00e9 l&rsquo;int\u00e9gration du composant \u00e9lectrique, \u00e0 savoir : la puissance de la batterie qui est prot\u00e9g\u00e9e et la valeur finale qui est atteinte plus rapidement car la courbe est plus importante. La conductivit\u00e9 de la pompe \u00e0 main est conforme aux directives ATEX : toutes les pi\u00e8ces m\u00e9talliques sont reli\u00e9es entre elles en permanence, de sorte qu&rsquo;elles ne peuvent pas \u00eatre charg\u00e9es. Cela permet simultan\u00e9ment d&rsquo;\u00e9viter les effets du phosphore dus \u00e0 la friction des particules pi\u00e9g\u00e9es telles que les copeaux.<\/p>\n<p>En outre, le syst\u00e8me piston\/cylindre de la pompe est r\u00e9gl\u00e9 de mani\u00e8re \u00e0 ne pas chauffer pendant le processus de pompage.<\/p>\n<p>Le CPH7000 et les op\u00e9rations d&rsquo;\u00e9talonnage sont effectu\u00e9s selon un ensemble de param\u00e8tres et contr\u00f4l\u00e9s sur un \u00e9cran tactile intuitif semblable \u00e0 celui d&rsquo;un smartphone. Gr\u00e2ce \u00e0 son amplitude, l&rsquo;interface utilisateur graphique facilite la navigation. Il est fabriqu\u00e9 en verre de s\u00e9curit\u00e9 car, dans le cas contraire, il pourrait se briser en cas de chute de l&rsquo;instrument, ce qui entra\u00eenerait l&rsquo;exposition de c\u00e2bles \u00e9lectriques dans des zones class\u00e9es. S&rsquo;il devait \u00eatre heurt\u00e9 plus fort que lors d&rsquo;une simple chute, l&rsquo;\u00e9cran pourrait se fragmenter, mais il formerait toujours une surface ferm\u00e9e.<\/p>\n<p>Les transmetteurs de pression de l&rsquo;installation multifonctions sont \u00e9talonn\u00e9s avec le calibrateur portable mod\u00e8le CPH7000 : les instruments de mesure sont int\u00e9gr\u00e9s dans le process au moyen de monobrides avec un raccord Ermeto comme raccord de test. Un capteur de r\u00e9f\u00e9rence externe CPT7000 est install\u00e9 sur le raccord pendant le test. Il est aliment\u00e9 \u00e0 la m\u00eame pression que le transmetteur et transf\u00e8re la valeur au calibrateur sous forme de signal num\u00e9rique. Il est possible de visualiser le r\u00e9sultat de l&rsquo;\u00e9talonnage instantan\u00e9ment : si l&rsquo;\u00e9l\u00e9ment de test correspond \u00e0 la pr\u00e9cision de la cat\u00e9gorie, il est affich\u00e9 dans une case verte, sinon, il est affich\u00e9 dans une case rouge.<\/p>\n<p><strong>\u00c9talonnage de la tension et du courant<\/strong><\/p>\n<p>Bien que la fonction principale du CPH7000 soit d\u2019\u00e9talonner en pression les instruments de mesure, cet appareil portatif effectue \u00e9galement d&rsquo;autres tests en une seule intervention, par exemple, ceux relatifs \u00e0 la tension et au courant en relation avec le module \u00e9lectrique. Le test des interrupteurs et les simulations de capteurs ne sont que deux de ses options. Il est \u00e9galement possible de v\u00e9rifier les points de mesure de la temp\u00e9rature \u00e0 l&rsquo;aide d&rsquo;une sonde Pt100 certif\u00e9e ATEX. De plus, un module atmosph\u00e9rique externe et un barom\u00e8tre int\u00e9gr\u00e9 fournissent des informations sur la pression atmosph\u00e9rique, l&rsquo;humidit\u00e9 relative et la temp\u00e9rature ambiante. Gr\u00e2ce \u00e0 sa petite surface, ce module miniature ne n\u00e9cessite pas de conception \u00e0 s\u00e9curit\u00e9 intrins\u00e8que.<\/p>\n<p>Un enregistreur de donn\u00e9es stocke toutes les valeurs mesur\u00e9es et les param\u00e8tres \u00e0 des fins de documentation. L&rsquo;enregistreur de donn\u00e9es affiche \u00e9galement les cycles de pression et de temp\u00e9rature sur un graphique en temps r\u00e9el, de sorte que toute variation est instantan\u00e9ment d\u00e9tectable. Par cons\u00e9quent, le CPH7000 est \u00e9galement adapt\u00e9 aux tests d&rsquo;\u00e9tanch\u00e9it\u00e9.<\/p>\n<p>Les donn\u00e9es enregistr\u00e9es par la sonde peuvent \u00eatre envoy\u00e9es \u00e0 un ordinateur central ou \u00e0 un ordinateur portable pour un traitement ult\u00e9rieur. Dans le sens inverse, les routines d&rsquo;\u00e9talonnage peuvent \u00eatre t\u00e9l\u00e9charg\u00e9es de cette mani\u00e8re, ce qui rend les process de test dans les zones sensibles encore plus s\u00fbrs. Si l&rsquo;appareil \u00ab\u00a0associ\u00e9\u00a0\u00bb au CPH7000 est \u00e0 port\u00e9e de Bluetooth, les op\u00e9rateurs peuvent transmettre toutes les informations pertinentes sans m\u00eame quitter la zone classifi\u00e9e.<\/p>\n<p>Vid\u00e9o : Comment calibrer un transmetteur de pression sur site avec un calibrateur portable CPH7000<\/p>\n<div data-fullscreen=\"disabled\" data-mode=\"normal\" data-oembed=\"1\" data-provider=\"youtube\" data-reset-after-played id=\"arve-youtube-t4rh-rwvdq4\" style=\"max-width:900px;\" class=\"arve\">\n<div class=\"arve-inner\">\n<div style=\"aspect-ratio:500\/281\" class=\"arve-embed arve-embed--has-aspect-ratio\">\n<div class=\"arve-ar\" style=\"padding-top:56.200000%\"><\/div>\n<p>\t\t\t<iframe allow=\"accelerometer &apos;none&apos;;autoplay &apos;none&apos;;bluetooth &apos;none&apos;;browsing-topics &apos;none&apos;;camera &apos;none&apos;;clipboard-read &apos;none&apos;;clipboard-write;display-capture &apos;none&apos;;encrypted-media &apos;none&apos;;gamepad &apos;none&apos;;geolocation &apos;none&apos;;gyroscope &apos;none&apos;;hid &apos;none&apos;;identity-credentials-get &apos;none&apos;;idle-detection &apos;none&apos;;keyboard-map &apos;none&apos;;local-fonts;magnetometer &apos;none&apos;;microphone &apos;none&apos;;midi &apos;none&apos;;otp-credentials &apos;none&apos;;payment &apos;none&apos;;picture-in-picture;publickey-credentials-create &apos;none&apos;;publickey-credentials-get &apos;none&apos;;screen-wake-lock &apos;none&apos;;serial &apos;none&apos;;summarizer &apos;none&apos;;sync-xhr;usb &apos;none&apos;;web-share;window-management &apos;none&apos;;xr-spatial-tracking &apos;none&apos;;\" allowfullscreen=\"\" class=\"arve-iframe fitvidsignore\" credentialless data-arve=\"arve-youtube-t4rh-rwvdq4\" data-lenis-prevent=\"\" data-src-no-ap=\"https:\/\/www.youtube-nocookie.com\/embed\/T4rH-rWVdq4?feature=oembed&amp;iv_load_policy=3&amp;modestbranding=1&amp;rel=0&amp;autohide=1&amp;playsinline=0&amp;autoplay=0&amp;enablejsapi=1\" frameborder=\"0\" height=\"505.8\" loading=\"lazy\" name=\"\" referrerpolicy=\"strict-origin-when-cross-origin\" sandbox=\"allow-scripts allow-same-origin allow-presentation allow-popups allow-popups-to-escape-sandbox\" scrolling=\"no\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/T4rH-rWVdq4?feature=oembed&#038;iv_load_policy=3&#038;modestbranding=1&#038;rel=0&#038;autohide=1&#038;playsinline=0&#038;autoplay=0&#038;enablejsapi=1\" title=\"How to Calibrate and Span a Pressure Transmitter\" width=\"900\"><\/iframe><\/p><\/div>\n<\/p><\/div>\n<p>\t<script type=\"application\/ld+json\">{\"@context\":\"http:\\\/\\\/schema.org\\\/\",\"@id\":\"https:\\\/\\\/blog.wika.com\\\/fr\\\/savoir-faire\\\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\\\/#arve-youtube-t4rh-rwvdq4\",\"type\":\"VideoObject\",\"embedURL\":\"https:\\\/\\\/www.youtube-nocookie.com\\\/embed\\\/T4rH-rWVdq4?feature=oembed&iv_load_policy=3&modestbranding=1&rel=0&autohide=1&playsinline=0&autoplay=0&enablejsapi=1\",\"name\":\"How to Calibrate and Span a Pressure Transmitter\",\"thumbnailUrl\":\"https:\\\/\\\/i.ytimg.com\\\/vi\\\/T4rH-rWVdq4\\\/hqdefault.jpg\",\"uploadDate\":\"2017-06-27T13:40:37Z\",\"author\":\"Mensor LP\",\"description\":\"Find out how to calibrate and adjust the span of a Rosemount 3051 Pressure Transmitter with a 4-20 mA output using a WIKA CPH7000 Portable Process Calibrator.\\n\\nThe calibration and span adjustment of a pressure transmitter with a 4 to 20 mA output will be covered in this video. We\\u2019ll use a WIKA CPH7000 Portable Process Calibrator and a Rosemount 3051 Pressure Transmitter. The pneumatic output of the calibrator should be connected to the pressure input of the transmitter. The electrical connections are made according to the diagram on the CPH7000 touchscreen. In this case, we need to power the Transmitter as well as read the mA signal.\\n\\nThe CPH7000 can generate and measure pressure while simultaneously measuring the 4 to 20 mA signal from the 3051 Pressure transmitter. By pressurizing the system to a specific point and comparing the output of the transmitter with the reading from the CPH7000, we can check the zero, span, and any pressure point in between.\\n\\nDuring this process, we can make adjustments to the 4 to 20 mA output of the transmitter. At zero pressure we want the output of the 3051 to be four mA. With the unit vented to the atmosphere simply press the zero button on the 3051. This will set the output to four mA at zero pressure. To set the span at 20 mA, pressurize the unit to 150 psi and press the span button. This sets the output to 20 mA at 150 psi.\\n\\nThe CPH7000 can also document the procedure using features within the calibration function and will guide the user in an as-found calibration.   \\n\\nWhen the calibration is complete a calibration report can be exported to a file for your records. \\n\\nThe product page for the CPH7000 and datasheet can be found at: \\n\\nGet yours today: \\n\\n...................................................................................................................................\\nFollow us on our social media channels:\\n\\ud83d\\udcfa YouTube: \\n\\ud83c\\udfaf LinkedIn:\"}<\/script><\/p>\n<\/div>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>L&rsquo;\u00e9talonnage des transmetteurs de pression \u00e0 s\u00e9curit\u00e9 intrins\u00e8que sur site n\u00e9cessite un \u00e9quipement approuv\u00e9 pour une utilisation dans des zones class\u00e9es, car les instruments conventionnels ne peuvent garantir une protection ad\u00e9quate. C&rsquo;est pourquoi WIKA a mis au point une nouvelle g\u00e9n\u00e9ration de calibrateurs multifonction portables, certifi\u00e9e pour les essais dans les environnements \u00e0 risque d&rsquo;explosion [&hellip;]<\/p>\n","protected":false},"author":129,"featured_media":8930,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5],"tags":[380,377,379,378],"class_list":["post-8927","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-savoir-faire","tag-atex","tag-calibrateur-process","tag-calibration","tag-talonnage-sur-site"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Les calibrateurs de process pour un etalonnage en zone Atex - Blog WIKA<\/title>\n<meta name=\"description\" content=\"WIKA a mis au point une nouvelle g\u00e9n\u00e9ration de calibrateurs multifonction portables, certifi\u00e9e pour les essais dans les zones ATEX.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Les calibrateurs de process pour un etalonnage en zone Atex - Blog WIKA\" \/>\n<meta property=\"og:description\" content=\"WIKA a mis au point une nouvelle g\u00e9n\u00e9ration de calibrateurs multifonction portables, certifi\u00e9e pour les essais dans les zones ATEX.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/\" \/>\n<meta property=\"og:site_name\" content=\"Blog WIKA\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/fr\/files\/2020\/09\/calibracion-de-presion-in-situ-wika.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Nicolas Chevin\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Nicolas Chevin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/\"},\"author\":{\"name\":\"Nicolas Chevin\",\"@id\":\"https:\/\/blog.wika.com\/fr\/#\/schema\/person\/2a33ccc9be3fddda787d057400006c06\"},\"headline\":\"Etalonnage en zone class\u00e9e ATEX gr\u00e2ce \u00e0 nos calibrateurs de process multifonction\",\"datePublished\":\"2020-10-05T06:38:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/\"},\"wordCount\":1521,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/#organization\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/fr\/files\/2020\/09\/calibracion-de-presion-in-situ-wika.jpg\",\"keywords\":[\"Atex\",\"calibrateur process\",\"calibration\",\"\u00e9talonnage sur site\"],\"articleSection\":[\"Savoir-faire\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/\",\"url\":\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/\",\"name\":\"Les calibrateurs de process pour un etalonnage en zone Atex - Blog WIKA\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/fr\/files\/2020\/09\/calibracion-de-presion-in-situ-wika.jpg\",\"datePublished\":\"2020-10-05T06:38:17+00:00\",\"description\":\"WIKA a mis au point une nouvelle g\u00e9n\u00e9ration de calibrateurs multifonction portables, certifi\u00e9e pour les essais dans les zones ATEX.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/fr\/files\/2020\/09\/calibracion-de-presion-in-situ-wika.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/fr\/files\/2020\/09\/calibracion-de-presion-in-situ-wika.jpg\",\"width\":838,\"height\":471},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/blog.wika.com\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Etalonnage en zone class\u00e9e ATEX gr\u00e2ce \u00e0 nos calibrateurs de process multifonction\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/fr\/#website\",\"url\":\"https:\/\/blog.wika.com\/fr\/\",\"name\":\"Blog WIKA\",\"description\":\"Notre blog vous propose de nombreux articles int\u00e9ressants sur la mesure de pression, temp\u00e9rature, niveau, d\u00e9bit et calibration et donne un aper\u00e7u du Groupe WIKA\",\"publisher\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/blog.wika.com\/fr\/#organization\",\"name\":\"WIKA Instruments\",\"url\":\"https:\/\/blog.wika.com\/fr\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/blog.wika.com\/fr\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/blog.wika.com\/fr\/files\/2016\/02\/logo_wika_cmyk.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/fr\/files\/2016\/02\/logo_wika_cmyk.jpg\",\"width\":758,\"height\":263,\"caption\":\"WIKA Instruments\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/fr\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/fr\/#\/schema\/person\/2a33ccc9be3fddda787d057400006c06\",\"name\":\"Nicolas Chevin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/blog.wika.com\/fr\/files\/2017\/11\/chevinnicolas-1_fr-fr-140x140.jpg\",\"url\":\"https:\/\/blog.wika.com\/fr\/files\/2017\/11\/chevinnicolas-1_fr-fr-140x140.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/fr\/files\/2017\/11\/chevinnicolas-1_fr-fr-140x140.jpg\",\"caption\":\"Nicolas Chevin\"},\"description\":\"D\u00e9sormais en charge de la gamme de produits \u00ab Calibration \u00bb, et fort d\u2019une exp\u00e9rience de 15 ans dans le domaine de l\u2019instrumentation de mesure et de la m\u00e9trologie, je serai votre contact privil\u00e9gi\u00e9 pour toute demande d\u2019information sur le mat\u00e9riel d\u2019\u00e9talonnage mais aussi sur les services associ\u00e9s propos\u00e9s par notre Laboratoire COFRAC chez Wika\",\"url\":\"https:\/\/blog.wika.com\/fr\/author\/fraisso\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Les calibrateurs de process pour un etalonnage en zone Atex - Blog WIKA","description":"WIKA a mis au point une nouvelle g\u00e9n\u00e9ration de calibrateurs multifonction portables, certifi\u00e9e pour les essais dans les zones ATEX.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/","og_locale":"fr_FR","og_type":"article","og_title":"Les calibrateurs de process pour un etalonnage en zone Atex - Blog WIKA","og_description":"WIKA a mis au point une nouvelle g\u00e9n\u00e9ration de calibrateurs multifonction portables, certifi\u00e9e pour les essais dans les zones ATEX.","og_url":"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/","og_site_name":"Blog WIKA","og_image":[{"width":838,"height":471,"url":"https:\/\/blog.wika.com\/fr\/files\/2020\/09\/calibracion-de-presion-in-situ-wika.jpg","type":"image\/jpeg"}],"author":"Nicolas Chevin","twitter_misc":{"\u00c9crit par":"Nicolas Chevin","Dur\u00e9e de lecture estim\u00e9e":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/"},"author":{"name":"Nicolas Chevin","@id":"https:\/\/blog.wika.com\/fr\/#\/schema\/person\/2a33ccc9be3fddda787d057400006c06"},"headline":"Etalonnage en zone class\u00e9e ATEX gr\u00e2ce \u00e0 nos calibrateurs de process multifonction","datePublished":"2020-10-05T06:38:17+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/"},"wordCount":1521,"commentCount":0,"publisher":{"@id":"https:\/\/blog.wika.com\/fr\/#organization"},"image":{"@id":"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/fr\/files\/2020\/09\/calibracion-de-presion-in-situ-wika.jpg","keywords":["Atex","calibrateur process","calibration","\u00e9talonnage sur site"],"articleSection":["Savoir-faire"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/","url":"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/","name":"Les calibrateurs de process pour un etalonnage en zone Atex - Blog WIKA","isPartOf":{"@id":"https:\/\/blog.wika.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/fr\/files\/2020\/09\/calibracion-de-presion-in-situ-wika.jpg","datePublished":"2020-10-05T06:38:17+00:00","description":"WIKA a mis au point une nouvelle g\u00e9n\u00e9ration de calibrateurs multifonction portables, certifi\u00e9e pour les essais dans les zones ATEX.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#primaryimage","url":"https:\/\/blog.wika.com\/fr\/files\/2020\/09\/calibracion-de-presion-in-situ-wika.jpg","contentUrl":"https:\/\/blog.wika.com\/fr\/files\/2020\/09\/calibracion-de-presion-in-situ-wika.jpg","width":838,"height":471},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/fr\/savoir-faire\/etalonnage-en-zone-classe-atex-grace-a-nos-calibrateurs-de-process-multifonction\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/blog.wika.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Etalonnage en zone class\u00e9e ATEX gr\u00e2ce \u00e0 nos calibrateurs de process multifonction"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/fr\/#website","url":"https:\/\/blog.wika.com\/fr\/","name":"Blog WIKA","description":"Notre blog vous propose de nombreux articles int\u00e9ressants sur la mesure de pression, temp\u00e9rature, niveau, d\u00e9bit et calibration et donne un aper\u00e7u du Groupe WIKA","publisher":{"@id":"https:\/\/blog.wika.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/blog.wika.com\/fr\/#organization","name":"WIKA Instruments","url":"https:\/\/blog.wika.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/blog.wika.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/blog.wika.com\/fr\/files\/2016\/02\/logo_wika_cmyk.jpg","contentUrl":"https:\/\/blog.wika.com\/fr\/files\/2016\/02\/logo_wika_cmyk.jpg","width":758,"height":263,"caption":"WIKA Instruments"},"image":{"@id":"https:\/\/blog.wika.com\/fr\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/blog.wika.com\/fr\/#\/schema\/person\/2a33ccc9be3fddda787d057400006c06","name":"Nicolas Chevin","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/blog.wika.com\/fr\/files\/2017\/11\/chevinnicolas-1_fr-fr-140x140.jpg","url":"https:\/\/blog.wika.com\/fr\/files\/2017\/11\/chevinnicolas-1_fr-fr-140x140.jpg","contentUrl":"https:\/\/blog.wika.com\/fr\/files\/2017\/11\/chevinnicolas-1_fr-fr-140x140.jpg","caption":"Nicolas Chevin"},"description":"D\u00e9sormais en charge de la gamme de produits \u00ab Calibration \u00bb, et fort d\u2019une exp\u00e9rience de 15 ans dans le domaine de l\u2019instrumentation de mesure et de la m\u00e9trologie, je serai votre contact privil\u00e9gi\u00e9 pour toute demande d\u2019information sur le mat\u00e9riel d\u2019\u00e9talonnage mais aussi sur les services associ\u00e9s propos\u00e9s par notre Laboratoire COFRAC chez Wika","url":"https:\/\/blog.wika.com\/fr\/author\/fraisso\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/posts\/8927","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/users\/129"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/comments?post=8927"}],"version-history":[{"count":3,"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/posts\/8927\/revisions"}],"predecessor-version":[{"id":8933,"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/posts\/8927\/revisions\/8933"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/media\/8930"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/media?parent=8927"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/categories?post=8927"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/fr\/wp-json\/wp\/v2\/tags?post=8927"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}