{"id":7274,"date":"2017-01-12T07:51:36","date_gmt":"2017-01-12T09:51:36","guid":{"rendered":"https:\/\/blog.wika.com\/pt\/\/?p=7274"},"modified":"2024-07-04T12:15:29","modified_gmt":"2024-07-04T15:15:29","slug":"construcao-sonda-nivel-parte-2","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/","title":{"rendered":"A constru\u00e7\u00e3o da sonda de n\u00edvel \u2013 parte 2"},"content":{"rendered":"<p><strong>Em nosso \u00faltimo artigo, \u201c<a href=\"https:\/\/blog.wika.com\/pt\/\/know-how\/construcao-sonda-nivel-parte-1\/\" class=\"local-link\">A constru\u00e7\u00e3o da sonda de n\u00edvel \u2013 parte 1<\/a>\u201d, explicamos sobre a constru\u00e7\u00e3o da sonda de n\u00edvel, come\u00e7ando pela c\u00e9lula de medi\u00e7\u00e3o e seus eletr\u00f4nicos. Especificamente em rela\u00e7\u00e3o \u00e0 resist\u00eancia do meio e veda\u00e7\u00e3o \u00e0 prova de \u00e1gua, deve se prestar muita aten\u00e7\u00e3o \u00e0s caracter\u00edsticas f\u00edsicas de uma sonda de n\u00edvel.<\/strong><\/p>\n<p>Por exemplo, o desenvolvimento de uma sonda de n\u00edvel necessita de uma constru\u00e7\u00e3o otimizada do inv\u00f3lucro, um projeto especial para o cabo, uma sele\u00e7\u00e3o de materiais especificamente adequados para as aplica\u00e7\u00f5es do cabo utilizado e a constru\u00e7\u00e3o \u00e0 prova de falhas da entrada do cabo em conjunto com o pr\u00f3prio cabo \u00e0 prova de \u00e1gua no inv\u00f3lucro da sonda.<\/p>\n<h2>O inv\u00f3lucro:<\/h2>\n<p>O requisito chave para uma sonda de n\u00edvel \u00e9 a resist\u00eancia e veda\u00e7\u00e3o \u00e0 prova de \u00e1gua contra o meio a ser medido. Devido estes requisitos, \u00e9 sempre recomend\u00e1vel a escolha de uma sonda de n\u00edvel de alta qualidade, como o modelo <a href=\"http:\/\/www.wika.com.br\/lh_20_pt_br.WIKA\" class=\"ext-link\" rel=\"external nofollow\" onclick=\"this.target=&#039;_blank&#039;;\">LH-20<\/a> da WIKA, com uma sele\u00e7\u00e3o de materiais adequados para o meio, um transmissor que foi constru\u00eddo e testado especialmente e exclusivamente para a medi\u00e7\u00e3o de n\u00edvel submers\u00edvel.<\/p>\n<p>Essencialmente, devemos sempre selecionar um material de inv\u00f3lucro que seja adequado ao meio a ser medido, prevenindo o processo de dissolu\u00e7\u00e3o e corros\u00e3o eletroqu\u00edmica. Para aplica\u00e7\u00f5es em meios n\u00e3o-cr\u00edticos, a escolha de a\u00e7o inoxid\u00e1vel, como o 316L, \u00e9 recomendada. Por\u00e9m, em aplica\u00e7\u00f5es com meios agressivos, o uso de um material especialmente adequado para os meios severos, como Hastelloy ou tit\u00e2nio, \u00e9 necess\u00e1rio. Mais informa\u00e7\u00f5es sobre a preven\u00e7\u00e3o de corros\u00e3o e falhas eletroquimicamente induzidas podem ser encontradas <a href=\"https:\/\/blog.wika.com\/pt\/\/know-how\/aterramento-de-sondas-de-nivel-previne-corrosao\/\" class=\"local-link\">aqui<\/a>.<\/p>\n<h2>A entrada do cabo:<\/h2>\n<p>Um dos pontos mais fracos da sonda de n\u00edvel \u00e9 a conex\u00e3o de cabo ao inv\u00f3lucro. Esta interface requer uma constru\u00e7\u00e3o refor\u00e7ada e hermeticamente vedada que garanta alta resist\u00eancia contra entrada de umidade, sob a press\u00e3o da \u00e1gua devido a grandes profundidades de imers\u00e3o e os efeitos de meios agressivos. \u00c9 importante evitar produtos cuja constru\u00e7\u00e3o da sonda de n\u00edvel seja baseada num sensor de press\u00e3o comumente utilizado na ind\u00fastria, \u201ccustomizado\u201d com uma sa\u00edda de cabo opcional.<\/p>\n<p>Uma sonda de n\u00edvel que deva funcionar confiavelmente e, sobretudo, continuamente at\u00e9 em ambientes severos, necessita ser um produto que foi especialmente desenvolvido para esta aplica\u00e7\u00e3o. Uma pequena quantidade de polui\u00e7\u00e3o de \u00e1gua subterr\u00e2nea, uma bomba danificada ou at\u00e9 mesmo uma falha na distribui\u00e7\u00e3o de \u00e1gua e saneamento s\u00e3o perigos constantes de um produto inadequado.<\/p>\n<h2>O cabo:<\/h2>\n<p>O cabo representa a distin\u00e7\u00e3o mais importante entre uma sonda de n\u00edvel especialmente desenvolvida para esta aplica\u00e7\u00e3o ou um \u201csensor de n\u00edvel\u201d inferiormente projetado. O cabo de uma sonda de n\u00edvel \u00e9 permanente exposto aos efeitos diretos de meio e press\u00e3o hidrost\u00e1tica entorno da respectiva profundidade de imers\u00e3o. Com a sele\u00e7\u00e3o inadequada de material, existe um risco permanente de entrada de flu\u00eddo em cabo atrav\u00e9s da press\u00e3o de \u00e1gua transversal e assim risco de falha do sensor de n\u00edvel. Fabricantes especializadas como a WIKA, desta forma, oferecem uma ampla sele\u00e7\u00e3o de materiais de cabos, para garantir alt\u00edssima resist\u00eancia contra meios e assim confiabilidade de processo da aplica\u00e7\u00e3o em quest\u00e3o.<\/p>\n<p>O usu\u00e1rio pode escolher entre uma sele\u00e7\u00e3o de materiais de cabos testados adequadamente para a aplica\u00e7\u00e3o, dependendo da agressividade do l\u00edquido a ser medido como, por exemplo, cabo PUR como padr\u00e3o para aplica\u00e7\u00f5es n\u00e3o-cr\u00edticas, ou cabo FEP para l\u00edquidos agressivos. Em \u00faltimo lugar, mas n\u00e3o menos importante, s\u00e3o as caracter\u00edsticas mec\u00e2nicas do cabo como, por exemplo, a durabilidade mec\u00e2nica do cabo utilizado que deve ser considerada durante o desenvolvimento da sonda de n\u00edvel. O cabo deve oferecer uma resist\u00eancia m\u00e1xima contra press\u00e3o, at\u00e9 em altas profundidades de imers\u00e3o assim como em po\u00e7os ou monitora\u00e7\u00e3o de \u00e1gua subterr\u00e2nea. Al\u00e9m disso, a for\u00e7a espec\u00edfica de cabo, de acordo com a carga de alongamento e a influ\u00eancia mec\u00e2nica direta relacionada a curvas em cantos e outros desgaste, torna-se muito importante.<\/p>\n<p>Todas essas considera\u00e7\u00f5es nos auxiliam na busca do objetivo da preven\u00e7\u00e3o efetiva e permanente de entrada de l\u00edquido no cabo. Mais informa\u00e7\u00f5es sobre falhas relacionadas \u00e0 preven\u00e7\u00e3o de entrada de meio em sondas de n\u00edvel podem ser encontradas <a href=\"https:\/\/blog.wika.com\/pt\/\/know-how\/critrios-selecao-prevencao-falhas-relacionadas-umidade-sondas-nivel\/\" class=\"local-link\">aqui<\/a>.<\/p>\n<p>A WIKA oferece solu\u00e7\u00f5es completas para sua medi\u00e7\u00e3o de n\u00edvel hidrost\u00e1tica.<br \/>\nPara ajuda na sele\u00e7\u00e3o de sensor de press\u00e3o adequado para sua aplica\u00e7\u00e3o, por favor, preencha nosso <a href=\"https:\/\/www.wika.com\/pt-br\/contato.WIKA\" target=\"_blank\" rel=\"noopener external nofollow\" class=\"ext-link\" onclick=\"this.target=&#039;_blank&#039;;\">formul\u00e1rio de contato<\/a>.<\/p>\n<h3>Preencha o guia r\u00e1pido de configura\u00e7\u00e3o da sonda de n\u00edvel <a href=\"https:\/\/www.wika.com\/pt-br\/ls_10.WIKA?highlightedText=ls-10\" target=\"_blank\" rel=\"noopener external nofollow\" class=\"ext-link\" onclick=\"this.target=&#039;_blank&#039;;\">LS-10<\/a> (padr\u00e3o) ou LH-20 (alta performance):<\/h3>\n<p><a class=\"button white local-link\" href=\"https:\/\/blog.wika.com\/pt\/\/guia-rapido-configuracao-wika-ls-10-solicitacao-download\/\">Download: Guia r\u00e1pido de configura\u00e7\u00e3o LS-10<\/a><\/p>\n<p><a class=\"button white local-link\" href=\"https:\/\/blog.wika.com\/pt\/\/guia-rapido-configuracao-wika-lh-20-solicitacao-download\/\">Download: Guia r\u00e1pido de configura\u00e7\u00e3o LH-20<\/a><\/p>\n<hr \/>\n<div id=\"imcontent\" dir=\"ltr\">Voc\u00ea encontrar\u00e1 mais informa\u00e7\u00f5es sobre este assunto em nossa plataforma sobre a <a href=\"http:\/\/www.wika.com\/hydrostatic-level\" class=\"ext-link\" rel=\"external nofollow\" onclick=\"this.target=&#039;_blank&#039;;\">medi\u00e7\u00e3o de n\u00edvel atrav\u00e9s da press\u00e3o hidrost\u00e1tica<\/a> (em ingl\u00eas).<\/div>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Em nosso \u00faltimo artigo, \u201cA constru\u00e7\u00e3o da sonda de n\u00edvel \u2013 parte 1\u201d, explicamos sobre a constru\u00e7\u00e3o da sonda de n\u00edvel, come\u00e7ando pela c\u00e9lula de medi\u00e7\u00e3o e seus eletr\u00f4nicos. Especificamente em rela\u00e7\u00e3o \u00e0 resist\u00eancia do meio e veda\u00e7\u00e3o \u00e0 prova de \u00e1gua, deve se prestar muita aten\u00e7\u00e3o \u00e0s caracter\u00edsticas f\u00edsicas de uma sonda de n\u00edvel. [&hellip;]<\/p>\n","protected":false},"author":145,"featured_media":7277,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[13],"tags":[134,91],"class_list":["post-7274","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-know-how","tag-medicao-nivel-hidrostatica","tag-sonda-nivel"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>A constru\u00e7\u00e3o da sonda de n\u00edvel \u2013 parte 2 - WIKA blog<\/title>\n<meta name=\"description\" content=\"O desenvolvimento de uma sonda de n\u00edvel necessita de uma constru\u00e7\u00e3o otimizada do inv\u00f3lucro, um projeto especial para o cabo. Saiba mais\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"A constru\u00e7\u00e3o da sonda de n\u00edvel \u2013 parte 2 - WIKA blog\" \/>\n<meta property=\"og:description\" content=\"O desenvolvimento de uma sonda de n\u00edvel necessita de uma constru\u00e7\u00e3o otimizada do inv\u00f3lucro, um projeto especial para o cabo. Saiba mais\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/WIKA.BR\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/pt\/files\/2017\/01\/submersible-pressure-transmitter-WIKA.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Rafael Derencio\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Rafael Derencio\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. tempo de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/\"},\"author\":{\"name\":\"Rafael Derencio\",\"@id\":\"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/620aef9d524f897e34699ada1d637c1f\"},\"headline\":\"A constru\u00e7\u00e3o da sonda de n\u00edvel \u2013 parte 2\",\"datePublished\":\"2017-01-12T09:51:36+00:00\",\"dateModified\":\"2024-07-04T15:15:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/\"},\"wordCount\":893,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2017\/01\/submersible-pressure-transmitter-WIKA.jpg\",\"keywords\":[\"Medi\u00e7\u00e3o de n\u00edvel hidrost\u00e1tica\",\"Sonda de n\u00edvel\"],\"articleSection\":[\"Know-how\"],\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/\",\"url\":\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/\",\"name\":\"A constru\u00e7\u00e3o da sonda de n\u00edvel \u2013 parte 2 - WIKA blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2017\/01\/submersible-pressure-transmitter-WIKA.jpg\",\"datePublished\":\"2017-01-12T09:51:36+00:00\",\"dateModified\":\"2024-07-04T15:15:29+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/620aef9d524f897e34699ada1d637c1f\"},\"description\":\"O desenvolvimento de uma sonda de n\u00edvel necessita de uma constru\u00e7\u00e3o otimizada do inv\u00f3lucro, um projeto especial para o cabo. Saiba mais\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/pt\/files\/2017\/01\/submersible-pressure-transmitter-WIKA.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2017\/01\/submersible-pressure-transmitter-WIKA.jpg\",\"width\":838,\"height\":471},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/blog.wika.com\/pt\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"A constru\u00e7\u00e3o da sonda de n\u00edvel \u2013 parte 2\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/pt\/#website\",\"url\":\"https:\/\/blog.wika.com\/pt\/\",\"name\":\"WIKA blog\",\"description\":\"Artigos interessantes sobre medi\u00e7\u00e3o de press\u00e3o, temperatura, n\u00edvel, for\u00e7a, vaz\u00e3o, SF6 e sobre tecnologia de calibra\u00e7\u00e3o.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/pt\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/620aef9d524f897e34699ada1d637c1f\",\"name\":\"Rafael Derencio\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/blog.wika.com\/pt\/files\/2017\/11\/pic_pe_rafaelderencio_pt-br-140x140.jpg\",\"url\":\"https:\/\/blog.wika.com\/pt\/files\/2017\/11\/pic_pe_rafaelderencio_pt-br-140x140.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2017\/11\/pic_pe_rafaelderencio_pt-br-140x140.jpg\",\"caption\":\"Rafael Derencio\"},\"description\":\"With an interest in automation, control, and instrumentation systems, I have been working in related fields for over 15 years. Currently, at WIKA, I am the product manager for WEgrid, our product family responsible for equipment related to the entire life cycle of SF6 gas. This includes analyzers, detectors, densimeters, transmitters, handling equipment, and various accessories.\",\"url\":\"https:\/\/blog.wika.com\/pt\/author\/rderencio\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"A constru\u00e7\u00e3o da sonda de n\u00edvel \u2013 parte 2 - WIKA blog","description":"O desenvolvimento de uma sonda de n\u00edvel necessita de uma constru\u00e7\u00e3o otimizada do inv\u00f3lucro, um projeto especial para o cabo. Saiba mais","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/","og_locale":"pt_BR","og_type":"article","og_title":"A constru\u00e7\u00e3o da sonda de n\u00edvel \u2013 parte 2 - WIKA blog","og_description":"O desenvolvimento de uma sonda de n\u00edvel necessita de uma constru\u00e7\u00e3o otimizada do inv\u00f3lucro, um projeto especial para o cabo. Saiba mais","og_url":"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/","og_site_name":"WIKA blog","article_publisher":"https:\/\/www.facebook.com\/WIKA.BR","og_image":[{"width":838,"height":471,"url":"https:\/\/blog.wika.com\/pt\/files\/2017\/01\/submersible-pressure-transmitter-WIKA.jpg","type":"image\/jpeg"}],"author":"Rafael Derencio","twitter_misc":{"Escrito por":"Rafael Derencio","Est. tempo de leitura":"5 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/"},"author":{"name":"Rafael Derencio","@id":"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/620aef9d524f897e34699ada1d637c1f"},"headline":"A constru\u00e7\u00e3o da sonda de n\u00edvel \u2013 parte 2","datePublished":"2017-01-12T09:51:36+00:00","dateModified":"2024-07-04T15:15:29+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/"},"wordCount":893,"commentCount":0,"image":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/pt\/files\/2017\/01\/submersible-pressure-transmitter-WIKA.jpg","keywords":["Medi\u00e7\u00e3o de n\u00edvel hidrost\u00e1tica","Sonda de n\u00edvel"],"articleSection":["Know-how"],"inLanguage":"pt-BR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/","url":"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/","name":"A constru\u00e7\u00e3o da sonda de n\u00edvel \u2013 parte 2 - WIKA blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/pt\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/pt\/files\/2017\/01\/submersible-pressure-transmitter-WIKA.jpg","datePublished":"2017-01-12T09:51:36+00:00","dateModified":"2024-07-04T15:15:29+00:00","author":{"@id":"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/620aef9d524f897e34699ada1d637c1f"},"description":"O desenvolvimento de uma sonda de n\u00edvel necessita de uma constru\u00e7\u00e3o otimizada do inv\u00f3lucro, um projeto especial para o cabo. Saiba mais","breadcrumb":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/"]}]},{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#primaryimage","url":"https:\/\/blog.wika.com\/pt\/files\/2017\/01\/submersible-pressure-transmitter-WIKA.jpg","contentUrl":"https:\/\/blog.wika.com\/pt\/files\/2017\/01\/submersible-pressure-transmitter-WIKA.jpg","width":838,"height":471},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/pt\/know-how\/construcao-sonda-nivel-parte-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/blog.wika.com\/pt\/"},{"@type":"ListItem","position":2,"name":"A constru\u00e7\u00e3o da sonda de n\u00edvel \u2013 parte 2"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/pt\/#website","url":"https:\/\/blog.wika.com\/pt\/","name":"WIKA blog","description":"Artigos interessantes sobre medi\u00e7\u00e3o de press\u00e3o, temperatura, n\u00edvel, for\u00e7a, vaz\u00e3o, SF6 e sobre tecnologia de calibra\u00e7\u00e3o.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/pt\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/620aef9d524f897e34699ada1d637c1f","name":"Rafael Derencio","image":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/blog.wika.com\/pt\/files\/2017\/11\/pic_pe_rafaelderencio_pt-br-140x140.jpg","url":"https:\/\/blog.wika.com\/pt\/files\/2017\/11\/pic_pe_rafaelderencio_pt-br-140x140.jpg","contentUrl":"https:\/\/blog.wika.com\/pt\/files\/2017\/11\/pic_pe_rafaelderencio_pt-br-140x140.jpg","caption":"Rafael Derencio"},"description":"With an interest in automation, control, and instrumentation systems, I have been working in related fields for over 15 years. Currently, at WIKA, I am the product manager for WEgrid, our product family responsible for equipment related to the entire life cycle of SF6 gas. This includes analyzers, detectors, densimeters, transmitters, handling equipment, and various accessories.","url":"https:\/\/blog.wika.com\/pt\/author\/rderencio\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts\/7274","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/users\/145"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/comments?post=7274"}],"version-history":[{"count":14,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts\/7274\/revisions"}],"predecessor-version":[{"id":11331,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts\/7274\/revisions\/11331"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/media\/7277"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/media?parent=7274"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/categories?post=7274"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/tags?post=7274"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}