{"id":8034,"date":"2018-01-25T09:19:09","date_gmt":"2018-01-25T11:19:09","guid":{"rendered":"https:\/\/blog.wika.com\/pt\/\/?p=8034"},"modified":"2024-07-02T15:11:27","modified_gmt":"2024-07-02T18:11:27","slug":"calibracao-comparativa-vs-calibracao-por-ponto-fixo","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/","title":{"rendered":"Calibra\u00e7\u00e3o comparativa vs. calibra\u00e7\u00e3o por ponto fixo"},"content":{"rendered":"<p><strong>Na tecnologia de calibra\u00e7\u00e3o de temperatura, existem dois m\u00e9todos de calibra\u00e7\u00e3o &#8211; a calibra\u00e7\u00e3o comparativa (ou por compara\u00e7\u00e3o) e a calibra\u00e7\u00e3o por ponto fixo. O m\u00e9todo de calibra\u00e7\u00e3o a ser utilizado ser\u00e1 definido atrav\u00e9s das demandas de exatid\u00e3o e do tipo de instrumento a ser calibrado. O m\u00e9todo de calibra\u00e7\u00e3o mais utilizado \u00e9 o m\u00e9todo comparativo.<\/strong><\/p>\n<p>Ent\u00e3o, qual a diferen\u00e7a entre os m\u00e9todos de calibra\u00e7\u00e3o comparativos e a calibra\u00e7\u00e3o por pontos fixos? Utilizando como exemplo a calibra\u00e7\u00e3o de um term\u00f4metro de resist\u00eancia, este artigo de blog explica ambos os m\u00e9todos e, portanto, tenta transmitir ao leitor uma melhor compreens\u00e3o sobre o assunto.<\/p>\n<h2>A calibra\u00e7\u00e3o comparativa<\/h2>\n<p>Como o nome j\u00e1 indica, este tipo de calibra\u00e7\u00e3o \u00e9 realizado comparando um term\u00f4metro de resist\u00eancia a ser calibrado com um term\u00f4metro de resist\u00eancia de refer\u00eancia de qualidade superior. A refer\u00eancia de qualidade superior deve, portanto, possuir uma exatid\u00e3o tr\u00eas ou quatro vezes maior do que o term\u00f4metro de resist\u00eancia que est\u00e1 sendo calibrado. Ambos os instrumentos s\u00e3o colocados em uma fonte de temperatura homog\u00eanea. Ao inserir os instrumentos na fonte de temperatura, deve-se ter o cuidado de assegurar uma pequena dist\u00e2ncia entre eles e que as partes sens\u00edveis \u00e0 temperatura de ambos (ou seja, o sensor propriamente dito) estejam na mesma altura dentro do meio de equaliza\u00e7\u00e3o da fonte de temperatura. Como fontes de temperatura geralmente s\u00e3o utilizados os banhos l\u00edquidos ou os calibradores tipo bloco seco.<\/p>\n<h2>A calibra\u00e7\u00e3o por ponto fixo<\/h2>\n<p>A calibra\u00e7\u00e3o por ponto fixo, ao contrario da calibra\u00e7\u00e3o comparativa, \u00e9 realizada contra pontos fixos de temperatura definidos na Escala Internacional de Temperatura de 1990 (ITS-90), podendo ser pontos triplos, de fus\u00e3o ou solidifica\u00e7\u00e3o de subst\u00e2ncias puras. Os pontos fixos definem temperaturas em que o estado f\u00edsico das subst\u00e2ncias se modifica. O ponto fixo mais importante da ITS-90 \u00e9 o ponto triplo da \u00e1gua. A uma temperatura de 0,010 \u00b0C, o estado f\u00edsico da \u00e1gua de alta pureza dentro da c\u00e9lula est\u00e1 em constante mudan\u00e7a entre s\u00f3lido, l\u00edquido e gasoso. As propor\u00e7\u00f5es dos estados f\u00edsicos s\u00e3o mantidas. Geralmente, apenas laborat\u00f3rios nacionais ou laborat\u00f3rios qualificados para incertezas de medi\u00e7\u00e3o muito baixas trabalham com essas c\u00e9lulas de ponto fixo, uma vez que o investimento \u00e9 alto e estas s\u00e3o dedicadas especificamente para esta aplica\u00e7\u00e3o. TRP\u00b4s (Term\u00f4metros de Resist\u00eancia de Platina) altamente est\u00e1veis utilizados como instrumentos de refer\u00eancia em laborat\u00f3rios, normalmente s\u00e3o calibrados usando o m\u00e9todo de calibra\u00e7\u00e3o por ponto fixo. O sensor de refer\u00eancia \u00e9 inserido em uma c\u00e9lula de ponto fixo, que mant\u00e9m a temperatura constante durante um longo per\u00edodo.<\/p>\n<p><strong>Exemplo: pontos fixos de -189 a 660 \u00baC de acordo com ITS-910:<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td><strong>Ponto fixo<\/strong><\/td>\n<td><strong>Temperatura<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Ponto triplo do Arg\u00f4nio<\/td>\n<td>-189.3442 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ponto triplo do Merc\u00fario<\/td>\n<td>-38.8344 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ponto triplo da \u00c1gua<\/td>\n<td>0.01 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ponto de fus\u00e3o do G\u00e1lio<\/td>\n<td>29.7646 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ponto de solidifica\u00e7\u00e3o do \u00cdndio<\/td>\n<td>156.5985 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ponto de solidifica\u00e7\u00e3o do Estanho<\/td>\n<td>231.928 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ponto de solidifica\u00e7\u00e3o do Zinco<\/td>\n<td>419.527 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Ponto de solidifica\u00e7\u00e3o do Alum\u00ednio<\/td>\n<td>660.323 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Nota<\/strong><br \/>\n<span style=\"font-size: 1rem\">Para mais informa\u00e7\u00f5<\/span><span style=\"font-size: 1rem\">es sobre nossos servi\u00e7os &#8220;<\/span><a style=\"font-size: 1rem;background-color: #ffffff\" href=\"https:\/\/www.wika.com\/pt-br\/servico_de_calibracao_para_instrumentos_de_medicao_de_temperatura.WIKA\" target=\"_blank\" rel=\"noopener external nofollow\" class=\"ext-link\" onclick=\"this.target=&#039;_blank&#039;;\">Calibra\u00e7\u00e3o de temperatura<\/a><span style=\"font-size: 1rem\">&#8221; podem ser encontradas no site da <\/span><span style=\"font-size: 1rem\">WIKA<\/span><span style=\"font-size: 1rem\">.<\/span><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Na tecnologia de calibra\u00e7\u00e3o de temperatura, existem dois m\u00e9todos de calibra\u00e7\u00e3o &#8211; a calibra\u00e7\u00e3o comparativa (ou por compara\u00e7\u00e3o) e a calibra\u00e7\u00e3o por ponto fixo. O m\u00e9todo de calibra\u00e7\u00e3o a ser utilizado ser\u00e1 definido atrav\u00e9s das demandas de exatid\u00e3o e do tipo de instrumento a ser calibrado. O m\u00e9todo de calibra\u00e7\u00e3o mais utilizado \u00e9 o m\u00e9todo [&hellip;]<\/p>\n","protected":false},"author":146,"featured_media":8035,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[13],"tags":[331,184,340,341],"class_list":["post-8034","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-know-how","tag-calibrao","tag-principios-medicao","tag-sensor-de-temperatura","tag-termometro"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Calibra\u00e7\u00e3o: comparativa e por ponto fixo- WIKA blog<\/title>\n<meta name=\"description\" content=\"Na tecnologia de calibra\u00e7\u00e3o de temperatura, existem dois m\u00e9todos de calibra\u00e7\u00e3o - a calibra\u00e7\u00e3o comparativa e a calibra\u00e7\u00e3o por ponto fixo.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Calibra\u00e7\u00e3o: comparativa e por ponto fixo- WIKA blog\" \/>\n<meta property=\"og:description\" content=\"Na tecnologia de calibra\u00e7\u00e3o de temperatura, existem dois m\u00e9todos de calibra\u00e7\u00e3o - a calibra\u00e7\u00e3o comparativa e a calibra\u00e7\u00e3o por ponto fixo.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/WIKA.BR\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/pt\/files\/2017\/12\/vergleich_fixpunkt_838_471px_v1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"836\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Antonio Saboya\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Antonio Saboya\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. tempo de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/\"},\"author\":{\"name\":\"Antonio Saboya\",\"@id\":\"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/c59f2e5f3fabc04cb41fde2630d65c46\"},\"headline\":\"Calibra\u00e7\u00e3o comparativa vs. calibra\u00e7\u00e3o por ponto fixo\",\"datePublished\":\"2018-01-25T11:19:09+00:00\",\"dateModified\":\"2024-07-02T18:11:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/\"},\"wordCount\":585,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2017\/12\/vergleich_fixpunkt_838_471px_v1.jpg\",\"keywords\":[\"Calibra\u00e7\u00e3o\",\"Princ\u00edpios de medi\u00e7\u00e3o\",\"Sensor de temperatura\",\"Term\u00f4metro\"],\"articleSection\":[\"Know-how\"],\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/\",\"url\":\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/\",\"name\":\"Calibra\u00e7\u00e3o: comparativa e por ponto fixo- WIKA blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2017\/12\/vergleich_fixpunkt_838_471px_v1.jpg\",\"datePublished\":\"2018-01-25T11:19:09+00:00\",\"dateModified\":\"2024-07-02T18:11:27+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/c59f2e5f3fabc04cb41fde2630d65c46\"},\"description\":\"Na tecnologia de calibra\u00e7\u00e3o de temperatura, existem dois m\u00e9todos de calibra\u00e7\u00e3o - a calibra\u00e7\u00e3o comparativa e a calibra\u00e7\u00e3o por ponto fixo.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/pt\/files\/2017\/12\/vergleich_fixpunkt_838_471px_v1.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2017\/12\/vergleich_fixpunkt_838_471px_v1.jpg\",\"width\":836,\"height\":471},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/blog.wika.com\/pt\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Calibra\u00e7\u00e3o comparativa vs. calibra\u00e7\u00e3o por ponto fixo\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/pt\/#website\",\"url\":\"https:\/\/blog.wika.com\/pt\/\",\"name\":\"WIKA blog\",\"description\":\"Artigos interessantes sobre medi\u00e7\u00e3o de press\u00e3o, temperatura, n\u00edvel, for\u00e7a, vaz\u00e3o, SF6 e sobre tecnologia de calibra\u00e7\u00e3o.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/pt\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/c59f2e5f3fabc04cb41fde2630d65c46\",\"name\":\"Antonio Saboya\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/blog.wika.com\/pt\/files\/2016\/12\/saboyaantonio_pt-br-e1480959457213-140x140.jpg\",\"url\":\"https:\/\/blog.wika.com\/pt\/files\/2016\/12\/saboyaantonio_pt-br-e1480959457213-140x140.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2016\/12\/saboyaantonio_pt-br-e1480959457213-140x140.jpg\",\"caption\":\"Antonio Saboya\"},\"description\":\"Iniciei minha carreira na WIKA do Brasil como KAM na \u00e1rea de Oleo&amp;G\u00e1s, ap\u00f3s fui transferido para a Engenharia de Produtos onde atuo como Especialista de Produto da Linha de Tecnologia de Calibra\u00e7\u00e3o. Tenho mais de 20 anos de experi\u00eancia nas \u00e1reas de gest\u00e3o da qualidade e laborat\u00f3rios de metrologia acreditados pela CGCRE-INMETRO (press\u00e3o, temperatura e ensaios de PSV\u00b4s), tamb\u00e9m atuando em atividades t\u00e9cnicas correlacionadas ao meu trabalho, em Comiss\u00f5es de Estudo (CE) da ABNT e Comiss\u00f5es T\u00e9cnicas (CT) do INMETRO.\",\"sameAs\":[\"http:\/\/www.wika.com.br\"],\"url\":\"https:\/\/blog.wika.com\/pt\/author\/asaboya\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Calibra\u00e7\u00e3o: comparativa e por ponto fixo- WIKA blog","description":"Na tecnologia de calibra\u00e7\u00e3o de temperatura, existem dois m\u00e9todos de calibra\u00e7\u00e3o - a calibra\u00e7\u00e3o comparativa e a calibra\u00e7\u00e3o por ponto fixo.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/","og_locale":"pt_BR","og_type":"article","og_title":"Calibra\u00e7\u00e3o: comparativa e por ponto fixo- WIKA blog","og_description":"Na tecnologia de calibra\u00e7\u00e3o de temperatura, existem dois m\u00e9todos de calibra\u00e7\u00e3o - a calibra\u00e7\u00e3o comparativa e a calibra\u00e7\u00e3o por ponto fixo.","og_url":"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/","og_site_name":"WIKA blog","article_publisher":"https:\/\/www.facebook.com\/WIKA.BR","og_image":[{"width":836,"height":471,"url":"https:\/\/blog.wika.com\/pt\/files\/2017\/12\/vergleich_fixpunkt_838_471px_v1.jpg","type":"image\/jpeg"}],"author":"Antonio Saboya","twitter_misc":{"Escrito por":"Antonio Saboya","Est. tempo de leitura":"3 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/"},"author":{"name":"Antonio Saboya","@id":"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/c59f2e5f3fabc04cb41fde2630d65c46"},"headline":"Calibra\u00e7\u00e3o comparativa vs. calibra\u00e7\u00e3o por ponto fixo","datePublished":"2018-01-25T11:19:09+00:00","dateModified":"2024-07-02T18:11:27+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/"},"wordCount":585,"commentCount":0,"image":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/pt\/files\/2017\/12\/vergleich_fixpunkt_838_471px_v1.jpg","keywords":["Calibra\u00e7\u00e3o","Princ\u00edpios de medi\u00e7\u00e3o","Sensor de temperatura","Term\u00f4metro"],"articleSection":["Know-how"],"inLanguage":"pt-BR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/","url":"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/","name":"Calibra\u00e7\u00e3o: comparativa e por ponto fixo- WIKA blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/pt\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/pt\/files\/2017\/12\/vergleich_fixpunkt_838_471px_v1.jpg","datePublished":"2018-01-25T11:19:09+00:00","dateModified":"2024-07-02T18:11:27+00:00","author":{"@id":"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/c59f2e5f3fabc04cb41fde2630d65c46"},"description":"Na tecnologia de calibra\u00e7\u00e3o de temperatura, existem dois m\u00e9todos de calibra\u00e7\u00e3o - a calibra\u00e7\u00e3o comparativa e a calibra\u00e7\u00e3o por ponto fixo.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/"]}]},{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#primaryimage","url":"https:\/\/blog.wika.com\/pt\/files\/2017\/12\/vergleich_fixpunkt_838_471px_v1.jpg","contentUrl":"https:\/\/blog.wika.com\/pt\/files\/2017\/12\/vergleich_fixpunkt_838_471px_v1.jpg","width":836,"height":471},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/pt\/know-how\/calibracao-comparativa-vs-calibracao-por-ponto-fixo\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/blog.wika.com\/pt\/"},{"@type":"ListItem","position":2,"name":"Calibra\u00e7\u00e3o comparativa vs. calibra\u00e7\u00e3o por ponto fixo"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/pt\/#website","url":"https:\/\/blog.wika.com\/pt\/","name":"WIKA blog","description":"Artigos interessantes sobre medi\u00e7\u00e3o de press\u00e3o, temperatura, n\u00edvel, for\u00e7a, vaz\u00e3o, SF6 e sobre tecnologia de calibra\u00e7\u00e3o.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/pt\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/c59f2e5f3fabc04cb41fde2630d65c46","name":"Antonio Saboya","image":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/blog.wika.com\/pt\/files\/2016\/12\/saboyaantonio_pt-br-e1480959457213-140x140.jpg","url":"https:\/\/blog.wika.com\/pt\/files\/2016\/12\/saboyaantonio_pt-br-e1480959457213-140x140.jpg","contentUrl":"https:\/\/blog.wika.com\/pt\/files\/2016\/12\/saboyaantonio_pt-br-e1480959457213-140x140.jpg","caption":"Antonio Saboya"},"description":"Iniciei minha carreira na WIKA do Brasil como KAM na \u00e1rea de Oleo&amp;G\u00e1s, ap\u00f3s fui transferido para a Engenharia de Produtos onde atuo como Especialista de Produto da Linha de Tecnologia de Calibra\u00e7\u00e3o. Tenho mais de 20 anos de experi\u00eancia nas \u00e1reas de gest\u00e3o da qualidade e laborat\u00f3rios de metrologia acreditados pela CGCRE-INMETRO (press\u00e3o, temperatura e ensaios de PSV\u00b4s), tamb\u00e9m atuando em atividades t\u00e9cnicas correlacionadas ao meu trabalho, em Comiss\u00f5es de Estudo (CE) da ABNT e Comiss\u00f5es T\u00e9cnicas (CT) do INMETRO.","sameAs":["http:\/\/www.wika.com.br"],"url":"https:\/\/blog.wika.com\/pt\/author\/asaboya\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts\/8034","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/users\/146"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/comments?post=8034"}],"version-history":[{"count":10,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts\/8034\/revisions"}],"predecessor-version":[{"id":11278,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts\/8034\/revisions\/11278"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/media\/8035"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/media?parent=8034"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/categories?post=8034"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/tags?post=8034"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}