{"id":8716,"date":"2019-02-28T08:38:01","date_gmt":"2019-02-28T11:38:01","guid":{"rendered":"https:\/\/blog.wika.com\/pt\/\/?p=8716"},"modified":"2024-07-22T19:35:56","modified_gmt":"2024-07-22T22:35:56","slug":"integracao-de-sensores-instalacao-e-requisitos-emc","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/","title":{"rendered":"Integra\u00e7\u00e3o de sensores: instala\u00e7\u00e3o e requisitos EMC"},"content":{"rendered":"<p><strong>Ao aplicarmos sensores de press\u00e3o em ambientes industriais existem alguns requisitos essenciais que devem ser considerados durante a instala\u00e7\u00e3o para prote\u00e7\u00e3o mec\u00e2nica e eletromagn\u00e9tica do equipamento:<\/strong><\/p>\n<p><strong>Aspectos construtivos:<\/strong><br \/>\nDependendo do local de instala\u00e7\u00e3o e aplica\u00e7\u00e3o pretendida, o sensor ter\u00e1 uma constru\u00e7\u00e3o diferenciada: por exemplo, considerando o grau de prote\u00e7\u00e3o IP necess\u00e1rio, prote\u00e7\u00e3o contra umidade, conex\u00e3o ao processo rosqueada ou tipo \u201cclamp\u201d, conex\u00f5es el\u00e9tricas, etc&#8230;<\/p>\n<p>Para sensores de press\u00e3o, onde n\u00e3o \u00e9 poss\u00edvel projetar um inv\u00f3lucro mais robusto devido ao pouco espa\u00e7o dispon\u00edvel, deve-se assegurar que a conex\u00e3o el\u00e9trica, soldas ou componentes eletr\u00f4nicos n\u00e3o sejam danificados durante a instala\u00e7\u00e3o. O projeto mais adequado deve ser desenvolvido em conjunto com o usu\u00e1rio e o fabricante para atender aos requisitos mais cr\u00edticos.<\/p>\n<p>Quando o sensor de press\u00e3o estiver fixado ao processo, deve-se ter um cuidado especial para garantir que isso n\u00e3o afete o sinal do sensor devido \u00e0 tens\u00f5es no elemento sensor. O fabricante do sensor ou transmissor poder\u00e1 auxiliar com instru\u00e7\u00f5es de instala\u00e7\u00e3o especificas neste caso. A conex\u00e3o mec\u00e2nica rosqueada \u00e9 menos cr\u00edtica aqui, mas tamb\u00e9m exige mais espa\u00e7o para instala\u00e7\u00e3o e, possivelmente, com custos mais elevados para o usu\u00e1rio.<\/p>\n<p><strong>Aspectos EMC (compatibilidade eletromagn\u00e9tica)<\/strong><br \/>\nUm sensor de press\u00e3o geralmente deve ser o mais compacto poss\u00edvel. Isso tamb\u00e9m significa que muitas vezes n\u00e3o h\u00e1 espa\u00e7o f\u00edsico para medidas mais apuradas de controle EMC. A prote\u00e7\u00e3o eletromagn\u00e9tica mais apropriada deve ser aplicada pelo usu\u00e1rio para cada situa\u00e7\u00e3o.<br \/>\nPor exemplo, em um sinal n\u00e3o amplificado de 2 mV\/V em sensores met\u00e1licos thin-film e sensores cer\u00e2micos, o usu\u00e1rio deve certificar-se que a dist\u00e2ncia at\u00e9 o painel de conex\u00f5es n\u00e3o seja elevada, ou na necessidade de transmitir o sinal em grandes dist\u00e2ncias um cabo com a prote\u00e7\u00e3o e blindagem adequadas deve ser utilizado.<\/p>\n<p>No geral, o usu\u00e1rio deve prever uma solu\u00e7\u00e3o para minimizar os efeitos da interfer\u00eancia eletromagn\u00e9tica para sua aplica\u00e7\u00e3o final. At\u00e9 mesmo em sensores com sinal amplificado e dependendo do sinal de sa\u00edda, o comprimento m\u00e1ximo do cabo deve ser observado no projeto. Sinais digitais de circuitos microprocessados, tais como I2C, s\u00e3o muito mais sens\u00edveis que os sinais de tens\u00e3o (por exemplo, 1\u2026 10 V) ou sinais de corrente (por exemplo, 4\u2026 20 mA).<\/p>\n<p><strong>Nota<\/strong><br \/>\nMais informa\u00e7\u00f5es sobre nossos <a href=\"https:\/\/www.wika.com\/pt-br\/sensores_de_pressao.WIKA\" target=\"_blank\" rel=\"noopener external nofollow\" class=\"ext-link\" onclick=\"this.target=&#039;_blank&#039;;\">sensores de press\u00e3o<\/a> podem ser encontradas no site da WIKA. Se voc\u00ea tiver alguma d\u00favida ou precisar de conselhos detalhados sobre aplica\u00e7\u00f5es de sensores de press\u00e3o, consulte nossa equipe de especialistas.<\/p>\n<p><strong>Veja tamb\u00e9m nossos artigos<\/strong><br \/>\n<a href=\"https:\/\/blog.wika.com\/pt\/\/produtos\/produtos-pressao\/quais_sao_os_niveis_de_configuracao_disponiveis_para_sensores_de_pressao\/\" class=\"local-link\">Quais s\u00e3o os n\u00edveis de configura\u00e7\u00e3o dispon\u00edveis para sensores de press\u00e3o?<\/a><br \/>\n<a href=\"https:\/\/blog.wika.com\/pt\/\/produtos\/produtos-pressao\/quais_sao_os_niveis_de_configuracao_disponiveis_para_sensores_de_pressao\/\" class=\"local-link\">Integra\u00e7\u00e3o de um elemento sensor de press\u00e3o &#8211; compensa\u00e7\u00e3o de erro de sinal para ponto zero e span<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Ao aplicarmos sensores de press\u00e3o em ambientes industriais existem alguns requisitos essenciais que devem ser considerados durante a instala\u00e7\u00e3o para prote\u00e7\u00e3o mec\u00e2nica e eletromagn\u00e9tica do equipamento: Aspectos construtivos: Dependendo do local de instala\u00e7\u00e3o e aplica\u00e7\u00e3o pretendida, o sensor ter\u00e1 uma constru\u00e7\u00e3o diferenciada: por exemplo, considerando o grau de prote\u00e7\u00e3o IP necess\u00e1rio, prote\u00e7\u00e3o contra umidade, conex\u00e3o [&hellip;]<\/p>\n","protected":false},"author":236,"featured_media":8717,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[13],"tags":[77],"class_list":["post-8716","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-know-how","tag-sensor-pressao"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Integra\u00e7\u00e3o de sensores: instala\u00e7\u00e3o e requisitos EMC<\/title>\n<meta name=\"description\" content=\"Ao aplicarmos sensores de press\u00e3o em ambientes industriais existem alguns requisitos essenciais que devem ser considerado. Saiba mais.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Integra\u00e7\u00e3o de sensores: instala\u00e7\u00e3o e requisitos EMC\" \/>\n<meta property=\"og:description\" content=\"Ao aplicarmos sensores de press\u00e3o em ambientes industriais existem alguns requisitos essenciais que devem ser considerado. Saiba mais.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/WIKA.BR\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/pt\/files\/2019\/02\/sensorintegration.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Samuel Marques\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Samuel Marques\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. tempo de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/\"},\"author\":{\"name\":\"Samuel Marques\",\"@id\":\"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/49896ad0fc6c48a1a7c141275f961fa8\"},\"headline\":\"Integra\u00e7\u00e3o de sensores: instala\u00e7\u00e3o e requisitos EMC\",\"datePublished\":\"2019-02-28T11:38:01+00:00\",\"dateModified\":\"2024-07-22T22:35:56+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/\"},\"wordCount\":514,\"commentCount\":2,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2019\/02\/sensorintegration.jpg\",\"keywords\":[\"Sensor de press\u00e3o\"],\"articleSection\":[\"Know-how\"],\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/\",\"url\":\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/\",\"name\":\"Integra\u00e7\u00e3o de sensores: instala\u00e7\u00e3o e requisitos EMC\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2019\/02\/sensorintegration.jpg\",\"datePublished\":\"2019-02-28T11:38:01+00:00\",\"dateModified\":\"2024-07-22T22:35:56+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/49896ad0fc6c48a1a7c141275f961fa8\"},\"description\":\"Ao aplicarmos sensores de press\u00e3o em ambientes industriais existem alguns requisitos essenciais que devem ser considerado. Saiba mais.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/pt\/files\/2019\/02\/sensorintegration.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2019\/02\/sensorintegration.jpg\",\"width\":838,\"height\":471,\"caption\":\"sensorintegration\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/blog.wika.com\/pt\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Integra\u00e7\u00e3o de sensores: instala\u00e7\u00e3o e requisitos EMC\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/pt\/#website\",\"url\":\"https:\/\/blog.wika.com\/pt\/\",\"name\":\"WIKA blog\",\"description\":\"Artigos interessantes sobre medi\u00e7\u00e3o de press\u00e3o, temperatura, n\u00edvel, for\u00e7a, vaz\u00e3o, SF6 e sobre tecnologia de calibra\u00e7\u00e3o.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/pt\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/49896ad0fc6c48a1a7c141275f961fa8\",\"name\":\"Samuel Marques\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/blog.wika.com\/pt\/files\/2019\/03\/marquessamuel_pt-br-1-140x140.jpg\",\"url\":\"https:\/\/blog.wika.com\/pt\/files\/2019\/03\/marquessamuel_pt-br-1-140x140.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2019\/03\/marquessamuel_pt-br-1-140x140.jpg\",\"caption\":\"Samuel Marques\"},\"description\":\"Engenheiro eletricista especialista em automa\u00e7\u00e3o industrial e p\u00f3s-graduado em gest\u00e3o de empresas e neg\u00f3cios. Sou respons\u00e1vel na WIKA do Brasil pela linha de medi\u00e7\u00e3o de press\u00e3o eletr\u00f4nica e WEgrid SF6 Atuei ao longo de 12 anos na implementa\u00e7\u00e3o de projetos EPC (Engineering, Procurement and Construction) com instrumenta\u00e7\u00e3o e automa\u00e7\u00e3o de processos nas ind\u00fastrias de celulose\/papel, minera\u00e7\u00e3o, \u00f3leo\/g\u00e1s e energia. Buscando sempre a excel\u00eancia no atendimento e foco no resultado.\",\"url\":\"https:\/\/blog.wika.com\/pt\/author\/smarques\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Integra\u00e7\u00e3o de sensores: instala\u00e7\u00e3o e requisitos EMC","description":"Ao aplicarmos sensores de press\u00e3o em ambientes industriais existem alguns requisitos essenciais que devem ser considerado. Saiba mais.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/","og_locale":"pt_BR","og_type":"article","og_title":"Integra\u00e7\u00e3o de sensores: instala\u00e7\u00e3o e requisitos EMC","og_description":"Ao aplicarmos sensores de press\u00e3o em ambientes industriais existem alguns requisitos essenciais que devem ser considerado. Saiba mais.","og_url":"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/","og_site_name":"WIKA blog","article_publisher":"https:\/\/www.facebook.com\/WIKA.BR","og_image":[{"width":838,"height":471,"url":"https:\/\/blog.wika.com\/pt\/files\/2019\/02\/sensorintegration.jpg","type":"image\/jpeg"}],"author":"Samuel Marques","twitter_misc":{"Escrito por":"Samuel Marques","Est. tempo de leitura":"3 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/"},"author":{"name":"Samuel Marques","@id":"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/49896ad0fc6c48a1a7c141275f961fa8"},"headline":"Integra\u00e7\u00e3o de sensores: instala\u00e7\u00e3o e requisitos EMC","datePublished":"2019-02-28T11:38:01+00:00","dateModified":"2024-07-22T22:35:56+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/"},"wordCount":514,"commentCount":2,"image":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/pt\/files\/2019\/02\/sensorintegration.jpg","keywords":["Sensor de press\u00e3o"],"articleSection":["Know-how"],"inLanguage":"pt-BR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/","url":"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/","name":"Integra\u00e7\u00e3o de sensores: instala\u00e7\u00e3o e requisitos EMC","isPartOf":{"@id":"https:\/\/blog.wika.com\/pt\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/pt\/files\/2019\/02\/sensorintegration.jpg","datePublished":"2019-02-28T11:38:01+00:00","dateModified":"2024-07-22T22:35:56+00:00","author":{"@id":"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/49896ad0fc6c48a1a7c141275f961fa8"},"description":"Ao aplicarmos sensores de press\u00e3o em ambientes industriais existem alguns requisitos essenciais que devem ser considerado. Saiba mais.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/"]}]},{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#primaryimage","url":"https:\/\/blog.wika.com\/pt\/files\/2019\/02\/sensorintegration.jpg","contentUrl":"https:\/\/blog.wika.com\/pt\/files\/2019\/02\/sensorintegration.jpg","width":838,"height":471,"caption":"sensorintegration"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/pt\/know-how\/integracao-de-sensores-instalacao-e-requisitos-emc\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/blog.wika.com\/pt\/"},{"@type":"ListItem","position":2,"name":"Integra\u00e7\u00e3o de sensores: instala\u00e7\u00e3o e requisitos EMC"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/pt\/#website","url":"https:\/\/blog.wika.com\/pt\/","name":"WIKA blog","description":"Artigos interessantes sobre medi\u00e7\u00e3o de press\u00e3o, temperatura, n\u00edvel, for\u00e7a, vaz\u00e3o, SF6 e sobre tecnologia de calibra\u00e7\u00e3o.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/pt\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/49896ad0fc6c48a1a7c141275f961fa8","name":"Samuel Marques","image":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/blog.wika.com\/pt\/files\/2019\/03\/marquessamuel_pt-br-1-140x140.jpg","url":"https:\/\/blog.wika.com\/pt\/files\/2019\/03\/marquessamuel_pt-br-1-140x140.jpg","contentUrl":"https:\/\/blog.wika.com\/pt\/files\/2019\/03\/marquessamuel_pt-br-1-140x140.jpg","caption":"Samuel Marques"},"description":"Engenheiro eletricista especialista em automa\u00e7\u00e3o industrial e p\u00f3s-graduado em gest\u00e3o de empresas e neg\u00f3cios. Sou respons\u00e1vel na WIKA do Brasil pela linha de medi\u00e7\u00e3o de press\u00e3o eletr\u00f4nica e WEgrid SF6 Atuei ao longo de 12 anos na implementa\u00e7\u00e3o de projetos EPC (Engineering, Procurement and Construction) com instrumenta\u00e7\u00e3o e automa\u00e7\u00e3o de processos nas ind\u00fastrias de celulose\/papel, minera\u00e7\u00e3o, \u00f3leo\/g\u00e1s e energia. Buscando sempre a excel\u00eancia no atendimento e foco no resultado.","url":"https:\/\/blog.wika.com\/pt\/author\/smarques\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts\/8716","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/users\/236"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/comments?post=8716"}],"version-history":[{"count":5,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts\/8716\/revisions"}],"predecessor-version":[{"id":11452,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts\/8716\/revisions\/11452"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/media\/8717"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/media?parent=8716"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/categories?post=8716"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/tags?post=8716"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}