{"id":9241,"date":"2020-07-30T15:10:29","date_gmt":"2020-07-30T18:10:29","guid":{"rendered":"https:\/\/blog.wika.com\/pt\/\/?p=9241"},"modified":"2024-07-02T14:30:36","modified_gmt":"2024-07-02T17:30:36","slug":"medicao-de-pressao-diferencial","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/","title":{"rendered":"As vantagens de se utilizar dois transmissores de processo interconectados para medi\u00e7\u00e3o de press\u00e3o diferencial"},"content":{"rendered":"<p><strong>O monitoramento do n\u00edvel de l\u00edquido atinge um novo auge com a solu\u00e7\u00e3o inovadora da WIKA: um sistema que usa dois transmissores de processo interconectados para medi\u00e7\u00e3o de press\u00e3o diferencial. Essa configura\u00e7\u00e3o \u00e9 extremamente precisa, f\u00e1cil de instalar e usar, e n\u00e3o suscet\u00edvel as varia\u00e7\u00f5es de temperatura.<\/strong><\/p>\n<p>Originalmente projetado para medir a press\u00e3o antes e depois do fluido encontrar um orif\u00edcio de restri\u00e7\u00e3o, um transmissor de press\u00e3o diferencial tamb\u00e9m pode determinar os n\u00edveis de l\u00edquido calculando a press\u00e3o diferencial entre as fases l\u00edquida e gasosa do fluido dentro de um tanque fechado. O principal problema, no entanto, \u00e9 que o tubo pequeno (capilar) usado para conectar essas duas fases est\u00e1 sujeito \u00e0 Lei de Gay-Lussac: dentro de um sistema fechado, a press\u00e3o de um g\u00e1s \u00e9 diretamente proporcional \u00e0 sua temperatura. Em outras palavras, temperaturas mais altas levam \u00e0 leituras de press\u00e3o maiores que as reais (consulte a <a href=\"https:\/\/blog.wika.com\/pt\/\/know-how\/usando-um-transmissor-de-pressao-diferencial-para-medicao-de-liquidos\/\" class=\"local-link\">Parte 1 desta s\u00e9rie<\/a>).<\/p>\n<h2>Medi\u00e7\u00e3o de press\u00e3o diferencial com dois transmissores de processo interconectados<\/h2>\n<p>A WIKA desenvolveu uma solu\u00e7\u00e3o para os desafios das flutua\u00e7\u00f5es de temperatura e leituras imprecisas. Nosso sistema inovador usa dois transmissores do mesmo processo, como o <a href=\"https:\/\/www.wika.com\/pt-br\/cpt_20_cpt_21.WIKA?highlightedText=CPT-2X\" target=\"_blank\" rel=\"noopener external nofollow\" class=\"ext-link\" onclick=\"this.target=&#039;_blank&#039;;\">CPT-2X<\/a> ou <a href=\"https:\/\/www.wika.com\/pt-br\/ipt_20_ipt_21.WIKA?highlightedText=ipt-2X\" target=\"_blank\" rel=\"noopener external nofollow\" class=\"ext-link\" onclick=\"this.target=&#039;_blank&#039;;\">IPT-2X<\/a>, e os conecta por meio de um cabo el\u00e9trico.<\/p>\n\n      <div class=\"wp-caption alignright\" style=\"max-width:190px;\"><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/pt\/\/files\/2020\/07\/figure-3-20200318105208.jpg\" alt=\"Medi\u00e7\u00e3o de n\u00edvel usando dois transmissores de processo interconectados\" \/><p class=\"wp-caption-text\">Medi\u00e7\u00e3o de n\u00edvel usando dois transmissores de processo interconectados<\/p><\/div>\n    \n<p>Nesta configura\u00e7\u00e3o, o transmissor de processo subordinado mede a press\u00e3o do g\u00e1s (P<sub>1<\/sub>) e comunica essa leitura ao principal atrav\u00e9s de um barramento interno (Figura ao lado). O transmissor principal mede a press\u00e3o do l\u00edquido (P<sub>2<\/sub>) e ent\u00e3o calcula a diferen\u00e7a entre P<sub>1<\/sub> e P<sub>2<\/sub>. Usando essa diferen\u00e7a, bem como par\u00e2metros pr\u00e9-programados, como as vari\u00e1veis geom\u00e9tricas do tanque e a densidade espec\u00edfica do l\u00edquido, o principal \u00e9 capaz de determinar o volume e o n\u00edvel precisos do l\u00edquido. Em seguida, envia esse valor para uma sala de controle e \/ ou o exibe no transmissor como um sinal digital ou anal\u00f3gico. O principal tamb\u00e9m parametriza e alimenta o subordinado.<\/p>\n<p>Sem precisar usar capilares, esse sistema lida com grandes varia\u00e7\u00f5es de temperatura com facilidade. Sua exatid\u00e3o equivalente \u00e9 de at\u00e9 0,05% da faixa de medi\u00e7\u00e3o. Al\u00e9m disso, o cabo de sinal el\u00e9trico n\u00e3o \u00e9 suscet\u00edvel a falhas relacionadas aos capilares.<\/p>\n<h2>Transmissores de Press\u00e3o vs. Transmissores de Processo para medi\u00e7\u00e3o da press\u00e3o diferencial<\/h2>\n<p>Em teoria, esse sistema poderia funcionar com transmissores de press\u00e3o e transmissores de processo. No entanto, o uso de transmissores de press\u00e3o exigiria v\u00e1rios componentes adicionais:<\/p>\n<ul>\n<li>Um dispositivo para executar c\u00e1lculos<\/li>\n<li>Uma segunda fonte de tens\u00e3o para alimentar o subordinado<\/li>\n<li>Duas entradas de press\u00e3o<\/li>\n<\/ul>\n<p>Como os transmissores de processo j\u00e1 possuem todos os componentes acima, este \u00e9 um sistema mais simples e econ\u00f4mico.<\/p>\n<h2>Vantagens do uso de transmissores de processo para medi\u00e7\u00e3o de press\u00e3o diferencial<\/h2>\n<p>A solu\u00e7\u00e3o inteligente da WIKA n\u00e3o apenas minimiza a sensibilidade \u00e0s varia\u00e7\u00f5es de temperatura, mas tamb\u00e9m oferece outros benef\u00edcios importantes:<\/p>\n<ul>\n<li><strong>Tempo de resposta mais r\u00e1pido<\/strong>. Como n\u00e3o h\u00e1 capilares, n\u00e3o h\u00e1 necessidade de executar testes a montante para verificar se todas as bolhas de ar foram eliminadas das linhas press\u00e3o.<\/li>\n<li><strong>Substitui\u00e7\u00e3o mais f\u00e1cil e barata.<\/strong> No caso de um mau funcionamento, apenas o transmissor de processo com defeito deve ser substitu\u00eddo. Ao usar transmissores de press\u00e3o diferencial tradicionais, todo o sistema deve ser substitu\u00eddo.<\/li>\n<li><strong>Amplitude de sinal otimizada.<\/strong> Desde que o transmissor do processo n\u00e3o esteja abaixo do limite recomendado (normalmente inferior a 5: 1), os intervalos podem ser configurados individualmente, dimensionando a faixa de medi\u00e7\u00e3o de cada transmissor para os valores realmente relevantes para o processo.<\/li>\n<li><strong>Maior versatilidade.<\/strong> Este sistema \u00e9 ideal para l\u00edquidos homog\u00eaneos, bem como meios heterog\u00eaneos\/diversos.<\/li>\n<\/ul>\n<h2>Medi\u00e7\u00e3o de n\u00edvel em diversos meios<\/h2>\n<p>Um sistema que utiliza dois transmissores de processo para medi\u00e7\u00e3o de press\u00e3o diferencial \u00e9 ideal para medir o n\u00edvel em meios mistos. Na fabrica\u00e7\u00e3o de suco de frutas, por exemplo, esse tipo de sistema pode determinar a propor\u00e7\u00e3o de concentrado \/ \u00e1gua com base na densidade e, portanto, na mudan\u00e7a de press\u00e3o. Outro exemplo s\u00e3o os tanques de esgoto nos navios, onde a \u00e1gua se mistura com lubrificantes e outros fluidos. Os dois transmissores de processo conectados podem medir com precis\u00e3o a press\u00e3o diferencial devido \u00e0 densidade do meio e, em seguida, indicar quando o n\u00edvel da \u00e1gua atingiu o limite definido.<\/p>\n<h2>WIKA: um expert em medi\u00e7\u00e3o de press\u00e3o diferencial<\/h2>\n<p>A WIKA \u00e9 l\u00edder mundial na fabrica\u00e7\u00e3o de instrumentos de medi\u00e7\u00e3o, mas fazemos mais do que isso. Nossos engenheiros procuram constantemente maneiras inovadoras de resolver desafios dif\u00edceis. Esse sistema de uso de dois transmissores de processo interconectados para monitorar com precis\u00e3o os n\u00edveis de l\u00edquido \u00e9 simplesmente uma das muitas solu\u00e7\u00f5es que nossas equipes projetaram para aumentar a exatid\u00e3o e economizar tempo e dinheiro dos clientes.<\/p>\n<p>Voc\u00ea deve medir o n\u00edvel usando um indicador de n\u00edvel, um transmissor de press\u00e3o diferencial cl\u00e1ssico ou dois transmissores de processo interconectados? Cada aplica\u00e7\u00e3o possui suas vari\u00e1veis \u00fanicas que influ\u00eancia o tipo de instrumento escolhido. Para obter ajuda na determina\u00e7\u00e3o de qual solu\u00e7\u00e3o \u00e9 a mais eficiente e econ\u00f4mica para o seu processo, entre em contato com os especialistas da WIKA Brasil.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>O monitoramento do n\u00edvel de l\u00edquido atinge um novo auge com a solu\u00e7\u00e3o inovadora da WIKA: um sistema que usa dois transmissores de processo interconectados para medi\u00e7\u00e3o de press\u00e3o diferencial. Essa configura\u00e7\u00e3o \u00e9 extremamente precisa, f\u00e1cil de instalar e usar, e n\u00e3o suscet\u00edvel as varia\u00e7\u00f5es de temperatura. Originalmente projetado para medir a press\u00e3o antes e [&hellip;]<\/p>\n","protected":false},"author":236,"featured_media":9242,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[13],"tags":[120,216],"class_list":["post-9241","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-know-how","tag-medicao-nivel","tag-transmissor-processo"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>As vantagens de se utilizar dois transmissores de processo<\/title>\n<meta name=\"description\" content=\"O monitoramento do n\u00edvel de l\u00edquido atinge um novo auge com a solu\u00e7\u00e3o inovadora da WIKA! Saiba como lendo este artigo de blog.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"As vantagens de se utilizar dois transmissores de processo\" \/>\n<meta property=\"og:description\" content=\"O monitoramento do n\u00edvel de l\u00edquido atinge um novo auge com a solu\u00e7\u00e3o inovadora da WIKA! Saiba como lendo este artigo de blog.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/WIKA.BR\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/pt\/files\/2020\/07\/interconnected-process-transmitters_larger-20200318105925-838x471.png\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Samuel Marques\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Samuel Marques\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. tempo de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/\"},\"author\":{\"name\":\"Samuel Marques\",\"@id\":\"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/49896ad0fc6c48a1a7c141275f961fa8\"},\"headline\":\"As vantagens de se utilizar dois transmissores de processo interconectados para medi\u00e7\u00e3o de press\u00e3o diferencial\",\"datePublished\":\"2020-07-30T18:10:29+00:00\",\"dateModified\":\"2024-07-02T17:30:36+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/\"},\"wordCount\":955,\"commentCount\":4,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2020\/07\/interconnected-process-transmitters_larger-20200318105925-838x471.png\",\"keywords\":[\"Medi\u00e7\u00e3o de n\u00edvel\",\"Transmissor de processo\"],\"articleSection\":[\"Know-how\"],\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/\",\"url\":\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/\",\"name\":\"As vantagens de se utilizar dois transmissores de processo\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2020\/07\/interconnected-process-transmitters_larger-20200318105925-838x471.png\",\"datePublished\":\"2020-07-30T18:10:29+00:00\",\"dateModified\":\"2024-07-02T17:30:36+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/49896ad0fc6c48a1a7c141275f961fa8\"},\"description\":\"O monitoramento do n\u00edvel de l\u00edquido atinge um novo auge com a solu\u00e7\u00e3o inovadora da WIKA! Saiba como lendo este artigo de blog.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/pt\/files\/2020\/07\/interconnected-process-transmitters_larger-20200318105925-838x471.png\",\"contentUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2020\/07\/interconnected-process-transmitters_larger-20200318105925-838x471.png\",\"width\":838,\"height\":471},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/blog.wika.com\/pt\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"As vantagens de se utilizar dois transmissores de processo interconectados para medi\u00e7\u00e3o de press\u00e3o diferencial\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/pt\/#website\",\"url\":\"https:\/\/blog.wika.com\/pt\/\",\"name\":\"WIKA blog\",\"description\":\"Artigos interessantes sobre medi\u00e7\u00e3o de press\u00e3o, temperatura, n\u00edvel, for\u00e7a, vaz\u00e3o, SF6 e sobre tecnologia de calibra\u00e7\u00e3o.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/pt\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/49896ad0fc6c48a1a7c141275f961fa8\",\"name\":\"Samuel Marques\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/blog.wika.com\/pt\/files\/2019\/03\/marquessamuel_pt-br-1-140x140.jpg\",\"url\":\"https:\/\/blog.wika.com\/pt\/files\/2019\/03\/marquessamuel_pt-br-1-140x140.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/pt\/files\/2019\/03\/marquessamuel_pt-br-1-140x140.jpg\",\"caption\":\"Samuel Marques\"},\"description\":\"Engenheiro eletricista especialista em automa\u00e7\u00e3o industrial e p\u00f3s-graduado em gest\u00e3o de empresas e neg\u00f3cios. Sou respons\u00e1vel na WIKA do Brasil pela linha de medi\u00e7\u00e3o de press\u00e3o eletr\u00f4nica e WEgrid SF6 Atuei ao longo de 12 anos na implementa\u00e7\u00e3o de projetos EPC (Engineering, Procurement and Construction) com instrumenta\u00e7\u00e3o e automa\u00e7\u00e3o de processos nas ind\u00fastrias de celulose\/papel, minera\u00e7\u00e3o, \u00f3leo\/g\u00e1s e energia. Buscando sempre a excel\u00eancia no atendimento e foco no resultado.\",\"url\":\"https:\/\/blog.wika.com\/pt\/author\/smarques\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"As vantagens de se utilizar dois transmissores de processo","description":"O monitoramento do n\u00edvel de l\u00edquido atinge um novo auge com a solu\u00e7\u00e3o inovadora da WIKA! Saiba como lendo este artigo de blog.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/","og_locale":"pt_BR","og_type":"article","og_title":"As vantagens de se utilizar dois transmissores de processo","og_description":"O monitoramento do n\u00edvel de l\u00edquido atinge um novo auge com a solu\u00e7\u00e3o inovadora da WIKA! Saiba como lendo este artigo de blog.","og_url":"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/","og_site_name":"WIKA blog","article_publisher":"https:\/\/www.facebook.com\/WIKA.BR","og_image":[{"width":838,"height":471,"url":"https:\/\/blog.wika.com\/pt\/files\/2020\/07\/interconnected-process-transmitters_larger-20200318105925-838x471.png","type":"image\/png"}],"author":"Samuel Marques","twitter_misc":{"Escrito por":"Samuel Marques","Est. tempo de leitura":"6 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/"},"author":{"name":"Samuel Marques","@id":"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/49896ad0fc6c48a1a7c141275f961fa8"},"headline":"As vantagens de se utilizar dois transmissores de processo interconectados para medi\u00e7\u00e3o de press\u00e3o diferencial","datePublished":"2020-07-30T18:10:29+00:00","dateModified":"2024-07-02T17:30:36+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/"},"wordCount":955,"commentCount":4,"image":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/pt\/files\/2020\/07\/interconnected-process-transmitters_larger-20200318105925-838x471.png","keywords":["Medi\u00e7\u00e3o de n\u00edvel","Transmissor de processo"],"articleSection":["Know-how"],"inLanguage":"pt-BR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/","url":"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/","name":"As vantagens de se utilizar dois transmissores de processo","isPartOf":{"@id":"https:\/\/blog.wika.com\/pt\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/pt\/files\/2020\/07\/interconnected-process-transmitters_larger-20200318105925-838x471.png","datePublished":"2020-07-30T18:10:29+00:00","dateModified":"2024-07-02T17:30:36+00:00","author":{"@id":"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/49896ad0fc6c48a1a7c141275f961fa8"},"description":"O monitoramento do n\u00edvel de l\u00edquido atinge um novo auge com a solu\u00e7\u00e3o inovadora da WIKA! Saiba como lendo este artigo de blog.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/"]}]},{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#primaryimage","url":"https:\/\/blog.wika.com\/pt\/files\/2020\/07\/interconnected-process-transmitters_larger-20200318105925-838x471.png","contentUrl":"https:\/\/blog.wika.com\/pt\/files\/2020\/07\/interconnected-process-transmitters_larger-20200318105925-838x471.png","width":838,"height":471},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/pt\/know-how\/medicao-de-pressao-diferencial\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/blog.wika.com\/pt\/"},{"@type":"ListItem","position":2,"name":"As vantagens de se utilizar dois transmissores de processo interconectados para medi\u00e7\u00e3o de press\u00e3o diferencial"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/pt\/#website","url":"https:\/\/blog.wika.com\/pt\/","name":"WIKA blog","description":"Artigos interessantes sobre medi\u00e7\u00e3o de press\u00e3o, temperatura, n\u00edvel, for\u00e7a, vaz\u00e3o, SF6 e sobre tecnologia de calibra\u00e7\u00e3o.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/pt\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/pt\/#\/schema\/person\/49896ad0fc6c48a1a7c141275f961fa8","name":"Samuel Marques","image":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/blog.wika.com\/pt\/files\/2019\/03\/marquessamuel_pt-br-1-140x140.jpg","url":"https:\/\/blog.wika.com\/pt\/files\/2019\/03\/marquessamuel_pt-br-1-140x140.jpg","contentUrl":"https:\/\/blog.wika.com\/pt\/files\/2019\/03\/marquessamuel_pt-br-1-140x140.jpg","caption":"Samuel Marques"},"description":"Engenheiro eletricista especialista em automa\u00e7\u00e3o industrial e p\u00f3s-graduado em gest\u00e3o de empresas e neg\u00f3cios. Sou respons\u00e1vel na WIKA do Brasil pela linha de medi\u00e7\u00e3o de press\u00e3o eletr\u00f4nica e WEgrid SF6 Atuei ao longo de 12 anos na implementa\u00e7\u00e3o de projetos EPC (Engineering, Procurement and Construction) com instrumenta\u00e7\u00e3o e automa\u00e7\u00e3o de processos nas ind\u00fastrias de celulose\/papel, minera\u00e7\u00e3o, \u00f3leo\/g\u00e1s e energia. Buscando sempre a excel\u00eancia no atendimento e foco no resultado.","url":"https:\/\/blog.wika.com\/pt\/author\/smarques\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts\/9241","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/users\/236"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/comments?post=9241"}],"version-history":[{"count":7,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts\/9241\/revisions"}],"predecessor-version":[{"id":11264,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/posts\/9241\/revisions\/11264"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/media\/9242"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/media?parent=9241"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/categories?post=9241"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/pt\/wp-json\/wp\/v2\/tags?post=9241"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}