{"id":10507,"date":"2019-01-08T12:23:16","date_gmt":"2019-01-08T17:23:16","guid":{"rendered":"https:\/\/blog.wika.com\/us\/\/?p=10507"},"modified":"2023-02-23T14:14:48","modified_gmt":"2023-02-23T19:14:48","slug":"problems-with-verifying-thermocouple-accuracy-during-reactor-startups","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/","title":{"rendered":"The Problems with Verifying Thermocouple Accuracy During Reactor Startups"},"content":{"rendered":"<p><strong>Refinery operators who work with fixed bed catalysts place a high value on temperature accuracy, but they also don\u2019t want to waste time by taking unnecessary temperature readings. Thus, to better understand any radial temperature differences that may exist during normal operations, they might assume they can simply use the temperatures taken during the startup hold times to verify the accuracy of reactor thermocouples.<\/strong><\/p>\n<p>This approach toward verifying thermocouple accuracy certainly sounds plausible, not to mention easier and more cost effective than the alternative. Unfortunately, this shortcut doesn\u2019t really give operators the temperature information they need. What\u2019s more, by using startup temperatures rather than operating temperatures, there\u2019s no time to make any adjustments in case of problems.<\/p>\n<p>This misconception is similar to the thinking that if you simply buy thermocouples to standard or special limits, you already know the sensors\u2019 accuracy. While this approach may be suitable in applications where many thermocouples are getting general process information, it generally does not provide the precision needed for activities like reactor internal distribution evaluations (especially when a warranty is involved), SIL proof tests\/recertifications, or pulse tests designed for advanced multi-level flow mapping of a reactor. The pulse test mapping can also have warranty implications on catalyst loading guarantees, as well as catalyst performance guarantees.<\/p>\n<div style=\"width: 100%;float: left\"><a class=\"button white\" style=\"float: right\" href=\"https:\/\/wika.pages.salesfusion.com\/Verifying-Thermocouple-Accuracy-Whitepaper-Gate\" rel=\"external\" target=\"_blank\"><span>To read the entire paper, click here for a free download<\/span><\/a><\/div>\n<div>\u00a0<\/div>\n<div>\u00a0<\/div>\n<div>\u00a0<\/div>\n<div>[contact-form-7 id=&#8221;14552&#8243; title=&#8221;Blog Contact Form&#8221;]<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Refinery operators who work with fixed bed catalysts place a high value on temperature accuracy, but they also don\u2019t want to waste time by taking unnecessary temperature readings. Thus, to better understand any radial temperature differences that may exist during normal operations, they might assume they can simply use the temperatures taken during the startup [&hellip;]<\/p>\n","protected":false},"author":190,"featured_media":8769,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5],"tags":[15,565,733,437,692,323,765],"class_list":["post-10507","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowhow","tag-accuracy","tag-calibration","tag-refinery","tag-temperature-measurement","tag-temperature-sensor","tag-thermocouple","tag-type-k-thermocouple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Problems with Thermocouple Accuracy in Reactor Startup - WIKA blog<\/title>\n<meta name=\"description\" content=\"Some refinery operators use the temperatures taken during startup hold times to verify thermocouple accuracy. However, this shortcut is not a good practice.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Problems with Thermocouple Accuracy in Reactor Startup - WIKA blog\" \/>\n<meta property=\"og:description\" content=\"Some refinery operators use the temperatures taken during startup hold times to verify thermocouple accuracy. However, this shortcut is not a good practice.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/us\/files\/2018\/02\/blog_image_2_15_18.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Robert Torgerson\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Robert Torgerson\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/\"},\"author\":{\"name\":\"Robert Torgerson\",\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/1a0b56b9c563f8b638494f482ea9eff2\"},\"headline\":\"The Problems with Verifying Thermocouple Accuracy During Reactor Startups\",\"datePublished\":\"2019-01-08T17:23:16+00:00\",\"dateModified\":\"2023-02-23T19:14:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/\"},\"wordCount\":243,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/us\/files\/2018\/02\/blog_image_2_15_18.jpeg\",\"keywords\":[\"Accuracy\",\"Calibration\",\"refinery\",\"temperature measurement\",\"temperature sensor\",\"Thermocouple\",\"type K thermocouple\"],\"articleSection\":[\"Know-how\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/\",\"url\":\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/\",\"name\":\"Problems with Thermocouple Accuracy in Reactor Startup - WIKA blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/us\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/us\/files\/2018\/02\/blog_image_2_15_18.jpeg\",\"datePublished\":\"2019-01-08T17:23:16+00:00\",\"dateModified\":\"2023-02-23T19:14:48+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/1a0b56b9c563f8b638494f482ea9eff2\"},\"description\":\"Some refinery operators use the temperatures taken during startup hold times to verify thermocouple accuracy. However, this shortcut is not a good practice.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/us\/files\/2018\/02\/blog_image_2_15_18.jpeg\",\"contentUrl\":\"https:\/\/blog.wika.com\/us\/files\/2018\/02\/blog_image_2_15_18.jpeg\",\"width\":838,\"height\":471,\"caption\":\"Temperature Sensors Expertise\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.wika.com\/us\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"The Problems with Verifying Thermocouple Accuracy During Reactor Startups\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/us\/#website\",\"url\":\"https:\/\/blog.wika.com\/us\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/us\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/1a0b56b9c563f8b638494f482ea9eff2\",\"name\":\"Robert Torgerson\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.wika.com\/us\/files\/2024\/02\/roberttorgerson250-2-120x120.jpg\",\"url\":\"https:\/\/blog.wika.com\/us\/files\/2024\/02\/roberttorgerson250-2-120x120.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/us\/files\/2024\/02\/roberttorgerson250-2-120x120.jpg\",\"caption\":\"Robert Torgerson\"},\"url\":\"https:\/\/blog.wika.com\/us\/author\/rtorgerson\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Problems with Thermocouple Accuracy in Reactor Startup - WIKA blog","description":"Some refinery operators use the temperatures taken during startup hold times to verify thermocouple accuracy. However, this shortcut is not a good practice.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/","og_locale":"en_US","og_type":"article","og_title":"Problems with Thermocouple Accuracy in Reactor Startup - WIKA blog","og_description":"Some refinery operators use the temperatures taken during startup hold times to verify thermocouple accuracy. However, this shortcut is not a good practice.","og_url":"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/","og_site_name":"WIKA blog","og_image":[{"width":838,"height":471,"url":"https:\/\/blog.wika.com\/us\/files\/2018\/02\/blog_image_2_15_18.jpeg","type":"image\/jpeg"}],"author":"Robert Torgerson","twitter_misc":{"Written by":"Robert Torgerson","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/"},"author":{"name":"Robert Torgerson","@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/1a0b56b9c563f8b638494f482ea9eff2"},"headline":"The Problems with Verifying Thermocouple Accuracy During Reactor Startups","datePublished":"2019-01-08T17:23:16+00:00","dateModified":"2023-02-23T19:14:48+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/"},"wordCount":243,"commentCount":0,"image":{"@id":"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/us\/files\/2018\/02\/blog_image_2_15_18.jpeg","keywords":["Accuracy","Calibration","refinery","temperature measurement","temperature sensor","Thermocouple","type K thermocouple"],"articleSection":["Know-how"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/","url":"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/","name":"Problems with Thermocouple Accuracy in Reactor Startup - WIKA blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/us\/files\/2018\/02\/blog_image_2_15_18.jpeg","datePublished":"2019-01-08T17:23:16+00:00","dateModified":"2023-02-23T19:14:48+00:00","author":{"@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/1a0b56b9c563f8b638494f482ea9eff2"},"description":"Some refinery operators use the temperatures taken during startup hold times to verify thermocouple accuracy. However, this shortcut is not a good practice.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#primaryimage","url":"https:\/\/blog.wika.com\/us\/files\/2018\/02\/blog_image_2_15_18.jpeg","contentUrl":"https:\/\/blog.wika.com\/us\/files\/2018\/02\/blog_image_2_15_18.jpeg","width":838,"height":471,"caption":"Temperature Sensors Expertise"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/us\/knowhow\/problems-with-verifying-thermocouple-accuracy-during-reactor-startups\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/us\/"},{"@type":"ListItem","position":2,"name":"The Problems with Verifying Thermocouple Accuracy During Reactor Startups"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/us\/#website","url":"https:\/\/blog.wika.com\/us\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/1a0b56b9c563f8b638494f482ea9eff2","name":"Robert Torgerson","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.wika.com\/us\/files\/2024\/02\/roberttorgerson250-2-120x120.jpg","url":"https:\/\/blog.wika.com\/us\/files\/2024\/02\/roberttorgerson250-2-120x120.jpg","contentUrl":"https:\/\/blog.wika.com\/us\/files\/2024\/02\/roberttorgerson250-2-120x120.jpg","caption":"Robert Torgerson"},"url":"https:\/\/blog.wika.com\/us\/author\/rtorgerson\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/10507","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/users\/190"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/comments?post=10507"}],"version-history":[{"count":15,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/10507\/revisions"}],"predecessor-version":[{"id":15236,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/10507\/revisions\/15236"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/media\/8769"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/media?parent=10507"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/categories?post=10507"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/tags?post=10507"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}