{"id":12105,"date":"2019-08-02T12:29:58","date_gmt":"2019-08-02T17:29:58","guid":{"rendered":"https:\/\/blog.wika.com\/us\/\/?p=12105"},"modified":"2025-11-07T14:10:49","modified_gmt":"2025-11-07T19:10:49","slug":"the-importance-of-testing-high-pressure-measuring-instruments","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/","title":{"rendered":"The Importance of Testing High-Pressure Measuring Instruments"},"content":{"rendered":"<p><strong>High-pressure processes, which often come with high temperatures and strong vibrations as well, place significant stress on measuring instrumentation. That\u2019s why testing is such an important aspect of the manufacturing process.<\/strong><\/p>\n<p>WIKA designs and manufactures robust instruments that can withstand the high pressures, high temperatures, and strong vibrations found in low-density polyethylene (LDPE) processes, <span><a href=\"https:\/\/blog.wika.com\/us\/\/products\/pressure-products\/use-wikas-high-pressure-transmitter-precise-consistent-waterjet-cutting\/\">waterjet cutting<\/a><\/span>, hydraulic test benches, and other high-pressure processes. But our best practices go several steps further. We also perform extensive rigorous testing, both non-destructive and destructive, to ensure that our instruments continue to operate reliably and accurately when continually subjected to these tough conditions.<\/p>\n<h2><span>Thermocouple Testing<\/span><\/h2>\n<p>When using a thermocouple to measure temperature in a high-pressure process, the interface between the MI cable and the fitting connection is one area that can lead to problems. To ensure joint integrity, WIKA uses vacuum brazen joints instead of seal welding or hand brazing. We submit each joint to two tests:<\/p>\n<h3>1. Vibration test<\/h3>\n<p><span style=\"font-size: 1.125rem\"><\/span>WIKA performs vibration testing for both conventional and lens-ring thermocouple configurations in all three axes \u2013 X, Y, and Z \u2014 according to IEC 60068-2-6 standard. Vibration frequencies go from 10 to 500 Hz with an acceleration of 2.5 <em>g<\/em>. Test results reveal that the interface between the MI cable and the thermocouple fitting is unaffected by vibration.<span>\u00a0<\/span><\/p>\n\n      <div class=\"wp-caption alignright\" style=\"max-width:258px;\"><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/us\/\/files\/2019\/08\/stress-strain-curve-388x404.png\" alt=\"Stress-strain curve\" \/><p class=\"wp-caption-text\">Example of a stress-strain curve for vacuum brazen test samples<\/p><\/div>\n    \n<h3>2. Destructive tensile test<\/h3>\n<p>Vacuum brazen joints are subjected to destructive tensile tests, half at 1,112\u00b0F (600\u00b0C) and half at ambient temperature. The resulting curve confirms that the average tensile rupture force and calculated shear strength of WIKA\u2019s vacuum brazen joints at both temperatures largely exceed normal operation values in high-pressure applications. Furthermore, based on working pressures of up to ~3,200 bar, the vacuum brazen joint continues to provide a reliable seal and continues to hold the MI cable in place.<\/p>\n<h2>Electronic Pressure Sensor Testing<\/h2>\n<p>For its metal thin-film pressure sensors, WIKA runs fatigue test using a 10<sup>8<\/sup>load cycles. Our engineers conduct environmental testing to ensure that the sensor can withstand exposure to water ingress (tested to NEAM 4X and IP65 standards). We also subject each production unit to a pressure stability test to ensure the part holds high pressure for a satisfactory period of time.<\/p>\n<h2>WIKA\u2019s Testing Capabilities<\/h2>\n<p>Each high-pressure application is different and may require running other tests on measuring instrumentation to ensure safe and reliable operations. WIKA\u2019s extensive testing facilities in our Klingenberg, Germany, headquarters have dedicated materials and environmental laboratories that can perform:<\/p>\n<ul>\n<li>Corrosion assays<\/li>\n<li>Dye penetrant tests<\/li>\n<li>Global UV testing<\/li>\n<li>Failure analysis<\/li>\n<li>Material analysis<\/li>\n<li>Microscopy<\/li>\n<li>Accuracy verification<\/li>\n<li>Climate (water, dust, salt spray, extreme temperatures) tests<\/li>\n<li>Shock tests<\/li>\n<li>Pressure strength determination<\/li>\n<li>Burst pressure tests<\/li>\n<li>Leakage testing<\/li>\n<li>IP protection verification<\/li>\n<li>EMC tests<\/li>\n<\/ul>\n<p>For more information about WIKA\u2019s rigorous tests for high-pressure instrumentation, contact our specialist.<\/p>\n<div style=\"width: 100%;float: left\"><a class=\"button white\" style=\"float: right\" href=\"https:\/\/www.wika.com\/en-us\/contact.WIKA\" rel=\"external\" target=\"_blank\"><span>Contact Us<\/span><\/a><\/div>\n<p>&nbsp;<\/p>\n<p><em>This is the final article in a three-part series on measuring instrumentation for high-pressure applications. Please also see <a href=\"https:\/\/blog.wika.com\/us\/\/applications\/thermocouples-highly-reliable-temperature-sensors-in-high-pressure-applications\/\">Thermocouples: Highly Reliable Temperature Sensors in High-Pressure Applications<\/a>\u00a0(part 1) and\u00a0<a href=\"https:\/\/blog.wika.com\/us\/\/applications\/electronic-instrumentation-for-safe-and-reliable-pressure-measurements-in-high-pressure-applications\/\">Electronic Instrumentation for Safe and Reliable Pressure Measurements in High-Pressure Applications<\/a> (part 2).<\/em><\/p>\n<p>[contact-form-7 id=&#8221;14552&#8243; title=&#8221;Blog Contact Form&#8221;]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>High-pressure processes, which often come with high temperatures and strong vibrations as well, place significant stress on measuring instrumentation. That\u2019s why testing is such an important aspect of the manufacturing process. WIKA designs and manufactures robust instruments that can withstand the high pressures, high temperatures, and strong vibrations found in low-density polyethylene (LDPE) processes, waterjet [&hellip;]<\/p>\n","protected":false},"author":277,"featured_media":12116,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[232],"tags":[986,830,437,323,477],"class_list":["post-12105","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications","tag-high-pressure","tag-high-temperature","tag-temperature-measurement","tag-thermocouple","tag-vibration"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Testing Thermocouples and Sensors Against Vibration and Temperature - WIKA blog<\/title>\n<meta name=\"description\" content=\"WIKA rigorously tests measuring instruments for high-pressure applications to make sure they can also withstand high temperatures and strong vibrations.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Testing Thermocouples and Sensors Against Vibration and Temperature - WIKA blog\" \/>\n<meta property=\"og:description\" content=\"WIKA rigorously tests measuring instruments for high-pressure applications to make sure they can also withstand high temperatures and strong vibrations.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/us\/files\/2019\/08\/shutterstock_72437509-1024x683.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"683\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Gabriel Rodrigues\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Gabriel Rodrigues\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/\"},\"author\":{\"name\":\"Gabriel Rodrigues\",\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/b5fb5c28071607a209d6c24992cf791c\"},\"headline\":\"The Importance of Testing High-Pressure Measuring Instruments\",\"datePublished\":\"2019-08-02T17:29:58+00:00\",\"dateModified\":\"2025-11-07T19:10:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/\"},\"wordCount\":523,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/us\/files\/2019\/08\/shutterstock_72437509.jpg\",\"keywords\":[\"high pressure\",\"high temperature\",\"temperature measurement\",\"Thermocouple\",\"vibration\"],\"articleSection\":[\"Applications\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/\",\"url\":\"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/\",\"name\":\"Testing Thermocouples and Sensors Against Vibration and Temperature - WIKA blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/us\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/us\/files\/2019\/08\/shutterstock_72437509.jpg\",\"datePublished\":\"2019-08-02T17:29:58+00:00\",\"dateModified\":\"2025-11-07T19:10:49+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/b5fb5c28071607a209d6c24992cf791c\"},\"description\":\"WIKA rigorously tests measuring instruments for high-pressure applications to make sure they can also withstand high temperatures and strong vibrations.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/us\/files\/2019\/08\/shutterstock_72437509.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/us\/files\/2019\/08\/shutterstock_72437509.jpg\",\"width\":4062,\"height\":2708,\"caption\":\"Polyethylene storage tanks at a chemical plant.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.wika.com\/us\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"The Importance of Testing High-Pressure Measuring Instruments\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/us\/#website\",\"url\":\"https:\/\/blog.wika.com\/us\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/us\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/b5fb5c28071607a209d6c24992cf791c\",\"name\":\"Gabriel Rodrigues\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.wika.com\/us\/files\/2015\/03\/default_avatar-140x140.png\",\"url\":\"https:\/\/blog.wika.com\/us\/files\/2015\/03\/default_avatar-140x140.png\",\"contentUrl\":\"https:\/\/blog.wika.com\/us\/files\/2015\/03\/default_avatar-140x140.png\",\"caption\":\"Gabriel Rodrigues\"},\"description\":\"I am a mechanical engineer with primary experience in production management and manufacturing processes for instrumentation used in measuring pressure, temperature, level, and flow. Working at WIKA Brazil since 2008, I have been involved in various departments such as Quality, Production, and Engineering. Currently, I am part of the Marketing\/Sales team as a Product Specialist for the Flow Line, responsible for product promotion, business analysis, and development.\",\"sameAs\":[\"http:\/\/www.wika.com.br\"],\"url\":\"https:\/\/blog.wika.com\/us\/author\/grodrigues\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Testing Thermocouples and Sensors Against Vibration and Temperature - WIKA blog","description":"WIKA rigorously tests measuring instruments for high-pressure applications to make sure they can also withstand high temperatures and strong vibrations.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/","og_locale":"en_US","og_type":"article","og_title":"Testing Thermocouples and Sensors Against Vibration and Temperature - WIKA blog","og_description":"WIKA rigorously tests measuring instruments for high-pressure applications to make sure they can also withstand high temperatures and strong vibrations.","og_url":"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/","og_site_name":"WIKA blog","og_image":[{"width":1024,"height":683,"url":"https:\/\/blog.wika.com\/us\/files\/2019\/08\/shutterstock_72437509-1024x683.jpg","type":"image\/jpeg"}],"author":"Gabriel Rodrigues","twitter_misc":{"Written by":"Gabriel Rodrigues","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/"},"author":{"name":"Gabriel Rodrigues","@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/b5fb5c28071607a209d6c24992cf791c"},"headline":"The Importance of Testing High-Pressure Measuring Instruments","datePublished":"2019-08-02T17:29:58+00:00","dateModified":"2025-11-07T19:10:49+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/"},"wordCount":523,"image":{"@id":"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/us\/files\/2019\/08\/shutterstock_72437509.jpg","keywords":["high pressure","high temperature","temperature measurement","Thermocouple","vibration"],"articleSection":["Applications"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/","url":"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/","name":"Testing Thermocouples and Sensors Against Vibration and Temperature - WIKA blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/us\/files\/2019\/08\/shutterstock_72437509.jpg","datePublished":"2019-08-02T17:29:58+00:00","dateModified":"2025-11-07T19:10:49+00:00","author":{"@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/b5fb5c28071607a209d6c24992cf791c"},"description":"WIKA rigorously tests measuring instruments for high-pressure applications to make sure they can also withstand high temperatures and strong vibrations.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/#primaryimage","url":"https:\/\/blog.wika.com\/us\/files\/2019\/08\/shutterstock_72437509.jpg","contentUrl":"https:\/\/blog.wika.com\/us\/files\/2019\/08\/shutterstock_72437509.jpg","width":4062,"height":2708,"caption":"Polyethylene storage tanks at a chemical plant."},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/us\/applications\/the-importance-of-testing-high-pressure-measuring-instruments\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/us\/"},{"@type":"ListItem","position":2,"name":"The Importance of Testing High-Pressure Measuring Instruments"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/us\/#website","url":"https:\/\/blog.wika.com\/us\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/b5fb5c28071607a209d6c24992cf791c","name":"Gabriel Rodrigues","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.wika.com\/us\/files\/2015\/03\/default_avatar-140x140.png","url":"https:\/\/blog.wika.com\/us\/files\/2015\/03\/default_avatar-140x140.png","contentUrl":"https:\/\/blog.wika.com\/us\/files\/2015\/03\/default_avatar-140x140.png","caption":"Gabriel Rodrigues"},"description":"I am a mechanical engineer with primary experience in production management and manufacturing processes for instrumentation used in measuring pressure, temperature, level, and flow. Working at WIKA Brazil since 2008, I have been involved in various departments such as Quality, Production, and Engineering. Currently, I am part of the Marketing\/Sales team as a Product Specialist for the Flow Line, responsible for product promotion, business analysis, and development.","sameAs":["http:\/\/www.wika.com.br"],"url":"https:\/\/blog.wika.com\/us\/author\/grodrigues\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/12105","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/users\/277"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/comments?post=12105"}],"version-history":[{"count":11,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/12105\/revisions"}],"predecessor-version":[{"id":16436,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/12105\/revisions\/16436"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/media\/12116"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/media?parent=12105"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/categories?post=12105"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/tags?post=12105"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}