{"id":12794,"date":"2020-01-24T10:46:02","date_gmt":"2020-01-24T15:46:02","guid":{"rendered":"https:\/\/blog.wika.com\/us\/\/?p=12794"},"modified":"2023-08-22T02:46:30","modified_gmt":"2023-08-22T07:46:30","slug":"averaging-resistance-temperature-detectors-hvac-applications","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/","title":{"rendered":"The Value of Using Averaging Resistance Temperature Detectors in HVAC Applications"},"content":{"rendered":"<p><b><span lang=\"EN-US\">When it comes to HVAC temperature measurements, a single point sometimes is not enough. An averaging RTD measures temperature along a duct or across a sectional area, resulting in more accurate information about the overall conditions inside HVAC units.<\/span><\/b><span><\/span><\/p>\n<p><span lang=\"EN-US\">Resistance temperature detectors (RTDs) are commonly found in ducts and heat exchangers to help HVAC equipment run more efficiently. However, when such units have only a single-point temperature sensor, operators run the risk of not seeing the bigger picture. One spot may run significantly hotter or cooler than others, or the air inside a duct could be stratified.<\/span><span><\/span><\/p>\n<h2>What Does an Averaging RTD Do?<\/h2>\n<p><span lang=\"EN-US\">To get a better picture of the overall temperature inside a duct or heat exchanger, users can install an averaging RTD along its length or across a section.<\/span><span><\/span><\/p>\n<p><span lang=\"EN-US\">An averaging RTD has long, flexible strips of sheathed platinum wires that can be bent and coiled into any configuration. Its<span class=\"apple-converted-space\">\u00a0<\/span><\/span><a href=\"https:\/\/blog.wika.com\/us\/\/products\/temperature-products\/pt100-and-pt1000-sensors-important-facts-and-differences\/\"><span lang=\"EN-US\">Pt100 sensor<\/span><\/a> <span lang=\"EN-US\">measures temperature along the entire length of the wires, which minimizes the risk of getting a too-hot or too-cold reading in gas compressors, air exchangers, and HVAC assemblies.<\/span><span><\/span><\/p>\n<h2>Highly Customizable Averaging RTD sensors<\/h2>\n\n      <div class=\"wp-caption alignright\" style=\"max-width:308px;\"><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/us\/\/files\/2020\/01\/avg-rtd_resized.png\" alt=\"Averaging RTD\" \/><p class=\"wp-caption-text\">Averaging RTD sensor<\/p><\/div>\n    \n<p><span lang=\"EN-US\">WIKA\u2019s<span class=\"apple-converted-space\">\u00a0<\/span><\/span><a href=\"https:\/\/www.wika.com\/en-us\/tr10_avg_tr15_avg.WIKA\" rel=\"external\" target=\"_blank\"><span lang=\"EN-US\">averaging RTD sensors<\/span><\/a><span lang=\"EN-US\">are extremely versatile. They measure a wide temperature range \u2013 from<span class=\"apple-converted-space\">\u00a0<\/span>\u221240\u00b0F to +392\u00b0F (\u221240\u00b0C to +200\u00b0C) \u2013 and can be customized to suit almost every HVAC application.<span class=\"apple-converted-space\">\u00a0<\/span><\/span><span><\/span><\/p>\n<p><span lang=\"EN-US\">The standard lengths are 4&#8242; (1.2m), 7&#8242; (2.1m) and 15&#8242; (4.6m), but the factory can trim them to customers\u2019 exact specification.<span class=\"apple-converted-space\">\u00a0<\/span>The sensors are sheathed in a flexible armor made of 316 stainless steel, which means they can be inserted directly into the process. They have ingress protection and FM (FM Global) and CSA (Canadian Standards Association) approval for use in explosion-proof hazardous locations.<\/span><span><\/span><\/p>\n<p><span lang=\"EN-US\">The <\/span><a href=\"https:\/\/blog.wika.com\/us\/\/products\/temperature-products\/rtds-3-wire-4-wire\/\"><span lang=\"EN-US\">3-wire or 4-wire<\/span><\/a> <span lang=\"EN-US\">configuration offers different levels of accuracy, precision, and repeatability. The sensors can come with or without a connection head. An optional Crastin terminal block reduces the risk of loose connections.<span class=\"apple-converted-space\">\u00a0<\/span><\/span><span><\/span><\/p>\n<p><span lang=\"EN-US\">WIKA\u2019s averaging RTDs come in a direct mount (<\/span>TR10<span lang=\"EN-US\">) or remote mount (<\/span>TR15<span lang=\"EN-US\">) version. The TR15 can be fitted with an up to 100&#8242; (30.5m) armored extension to reach deeper into an HVAC unit. This model also has the option of a digital programmable transmitter to convert the resistance output signal.<\/span><span><\/span><\/p>\n<p><span lang=\"EN-US\">Mounting is simple: Just secure the averaging RTD with clips or tie wires. Replacements are similarly hassle-free, as customers can order just another sensor without having to buy another terminal head as well.<\/span><span><\/span><\/p>\n<p><span lang=\"EN-US\">For more information about whether an averaging RTD sensor is right for your industrial HVAC applications, contact the temperature measurement experts at WIKA USA.<\/span><span><\/span><\/p>\n<div style=\"width: 100%;float: left\"><a class=\"button white\" style=\"float: right\" href=\"https:\/\/www.wika.com\/en-us\/contact.WIKA\" rel=\"external\" target=\"_blank\"><span>Contact Us<\/span><\/a><\/div>\n<h3><strong>Products in this post:<\/strong><\/h3>\n<ul>\n<li><span><\/span><strong><a href=\"https:\/\/www.wika.com\/en-us\/tr10_avg_tr15_avg.WIKA\" rel=\"external\" target=\"_blank\">Averaging RTD sensor<\/a><\/strong><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>When it comes to HVAC temperature measurements, a single point sometimes is not enough. An averaging RTD measures temperature along a duct or across a sectional area, resulting in more accurate information about the overall conditions inside HVAC units. Resistance temperature detectors (RTDs) are commonly found in ducts and heat exchangers to help HVAC equipment [&hellip;]<\/p>\n","protected":false},"author":226,"featured_media":12802,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221],"tags":[991,727,584],"class_list":["post-12794","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-temperature-products","tag-hvac","tag-multipoint-temperature-measurement","tag-rtd"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Flexible Averaging RTDs for HVAC Units - WIKA blog<\/title>\n<meta name=\"description\" content=\"An averaging resistance temperature detector (RTD) measures temperature over a length or cross section \u2013 instead of a single point \u2013 for greater accuracy.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Flexible Averaging RTDs for HVAC Units - WIKA blog\" \/>\n<meta property=\"og:description\" content=\"An averaging resistance temperature detector (RTD) measures temperature over a length or cross section \u2013 instead of a single point \u2013 for greater accuracy.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/us\/files\/2020\/01\/shutterstock_552537541_resized.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Patrick McGrath\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Patrick McGrath\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/\"},\"author\":{\"name\":\"Patrick McGrath\",\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/1e950391d76fa3fc04e91b9a0c1c5757\"},\"headline\":\"The Value of Using Averaging Resistance Temperature Detectors in HVAC Applications\",\"datePublished\":\"2020-01-24T15:46:02+00:00\",\"dateModified\":\"2023-08-22T07:46:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/\"},\"wordCount\":450,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/us\/files\/2020\/01\/shutterstock_552537541_resized.jpg\",\"keywords\":[\"HVAC\",\"multipoint temperature measurement\",\"RTD\"],\"articleSection\":[\"Temperature\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/\",\"url\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/\",\"name\":\"Flexible Averaging RTDs for HVAC Units - WIKA blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/us\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/us\/files\/2020\/01\/shutterstock_552537541_resized.jpg\",\"datePublished\":\"2020-01-24T15:46:02+00:00\",\"dateModified\":\"2023-08-22T07:46:30+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/1e950391d76fa3fc04e91b9a0c1c5757\"},\"description\":\"An averaging resistance temperature detector (RTD) measures temperature over a length or cross section \u2013 instead of a single point \u2013 for greater accuracy.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/us\/files\/2020\/01\/shutterstock_552537541_resized.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/us\/files\/2020\/01\/shutterstock_552537541_resized.jpg\",\"width\":838,\"height\":471,\"caption\":\"WIKA\u2019s averaging RTDs come in a direct mount (TR10) or remote mount (TR15) version. The TR15 can be fitted with an up to 100' (30.5m) armored extension to reach deeper into an HVAC unit.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.wika.com\/us\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"The Value of Using Averaging Resistance Temperature Detectors in HVAC Applications\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/us\/#website\",\"url\":\"https:\/\/blog.wika.com\/us\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/us\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/1e950391d76fa3fc04e91b9a0c1c5757\",\"name\":\"Patrick McGrath\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.wika.com\/us\/files\/2023\/03\/microsoftteams-image-11-pat-120x120.jpg\",\"url\":\"https:\/\/blog.wika.com\/us\/files\/2023\/03\/microsoftteams-image-11-pat-120x120.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/us\/files\/2023\/03\/microsoftteams-image-11-pat-120x120.jpg\",\"caption\":\"Patrick McGrath\"},\"url\":\"https:\/\/blog.wika.com\/us\/author\/pmcgrath\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Flexible Averaging RTDs for HVAC Units - WIKA blog","description":"An averaging resistance temperature detector (RTD) measures temperature over a length or cross section \u2013 instead of a single point \u2013 for greater accuracy.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/","og_locale":"en_US","og_type":"article","og_title":"Flexible Averaging RTDs for HVAC Units - WIKA blog","og_description":"An averaging resistance temperature detector (RTD) measures temperature over a length or cross section \u2013 instead of a single point \u2013 for greater accuracy.","og_url":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/","og_site_name":"WIKA blog","og_image":[{"width":838,"height":471,"url":"https:\/\/blog.wika.com\/us\/files\/2020\/01\/shutterstock_552537541_resized.jpg","type":"image\/jpeg"}],"author":"Patrick McGrath","twitter_misc":{"Written by":"Patrick McGrath","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/"},"author":{"name":"Patrick McGrath","@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/1e950391d76fa3fc04e91b9a0c1c5757"},"headline":"The Value of Using Averaging Resistance Temperature Detectors in HVAC Applications","datePublished":"2020-01-24T15:46:02+00:00","dateModified":"2023-08-22T07:46:30+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/"},"wordCount":450,"commentCount":0,"image":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/us\/files\/2020\/01\/shutterstock_552537541_resized.jpg","keywords":["HVAC","multipoint temperature measurement","RTD"],"articleSection":["Temperature"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/","url":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/","name":"Flexible Averaging RTDs for HVAC Units - WIKA blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/us\/files\/2020\/01\/shutterstock_552537541_resized.jpg","datePublished":"2020-01-24T15:46:02+00:00","dateModified":"2023-08-22T07:46:30+00:00","author":{"@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/1e950391d76fa3fc04e91b9a0c1c5757"},"description":"An averaging resistance temperature detector (RTD) measures temperature over a length or cross section \u2013 instead of a single point \u2013 for greater accuracy.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#primaryimage","url":"https:\/\/blog.wika.com\/us\/files\/2020\/01\/shutterstock_552537541_resized.jpg","contentUrl":"https:\/\/blog.wika.com\/us\/files\/2020\/01\/shutterstock_552537541_resized.jpg","width":838,"height":471,"caption":"WIKA\u2019s averaging RTDs come in a direct mount (TR10) or remote mount (TR15) version. The TR15 can be fitted with an up to 100' (30.5m) armored extension to reach deeper into an HVAC unit."},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/averaging-resistance-temperature-detectors-hvac-applications\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/us\/"},{"@type":"ListItem","position":2,"name":"The Value of Using Averaging Resistance Temperature Detectors in HVAC Applications"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/us\/#website","url":"https:\/\/blog.wika.com\/us\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/1e950391d76fa3fc04e91b9a0c1c5757","name":"Patrick McGrath","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.wika.com\/us\/files\/2023\/03\/microsoftteams-image-11-pat-120x120.jpg","url":"https:\/\/blog.wika.com\/us\/files\/2023\/03\/microsoftteams-image-11-pat-120x120.jpg","contentUrl":"https:\/\/blog.wika.com\/us\/files\/2023\/03\/microsoftteams-image-11-pat-120x120.jpg","caption":"Patrick McGrath"},"url":"https:\/\/blog.wika.com\/us\/author\/pmcgrath\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/12794","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/users\/226"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/comments?post=12794"}],"version-history":[{"count":7,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/12794\/revisions"}],"predecessor-version":[{"id":16414,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/12794\/revisions\/16414"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/media\/12802"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/media?parent=12794"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/categories?post=12794"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/tags?post=12794"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}