{"id":1518,"date":"2019-12-19T10:30:13","date_gmt":"2019-12-19T15:30:13","guid":{"rendered":"http:\/\/blog.wika.com\/us\/\/?p=1518"},"modified":"2025-05-15T09:40:23","modified_gmt":"2025-05-15T14:40:23","slug":"hf-alkylation-units-prevent-dangerous-emissions-leaks","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/","title":{"rendered":"HF Alkylation Units: Anti Corrosion Process Gauges to Prevent Leaks"},"content":{"rendered":"<p><strong>Alkylation units use very strong catalysts, such as hydrofluoric acid, to produce the components for high-octane gasoline. That\u2019s why refineries need process gauges and other pressure instruments that can withstand highly corrosive environments.<\/strong><\/p>\n<p>Petroleum refineries rely on alkylation units to produce higher-grade and, therefore, higher-value products. After a <a href=\"https:\/\/blog.wika.com\/us\/\/knowhow\/importance-dipleg-temperature-measurement-fcc-units\/\">fluidized catalytic cracking (FCC) unit<\/a> transforms heavy feedstock into short hydrocarbon chains, an alkylation unit further converts the molecules into alkylates, a higher-octane component of gasoline.<\/p>\n<h2>Hydrofluoric Acid: Effective and Hazardous<\/h2>\n<p>The alkylation process requires a strong catalyst, the most common of which are sulfuric acid and hydrofluoric acid (HF). The advantage of a hydrofluoric acid alkylation unit (HFAU) is that it uses less catalyst, processes a wider range of feedstocks, and produces higher-octane components than a sulfuric acid alkylation unit (SAAU).<\/p>\n<p>Needless to say, HF is highly hazardous. It can burn the lungs when inhaled and cause severe burns when it touches the skin. To keep technicians safe, an HF alkylation unit must constantly monitor the process to prevent vapor releases, fugitive emissions, and leaks.<\/p>\n<h2>Anti-corrosive Instruments for Alkylation Units<\/h2>\n<p>To properly monitor processes in an HFAU, the instruments themselves must be made of corrosion-resistant materials. WIKA has developed an <a href=\"https:\/\/www.wika.com\/en-us\/m932_d1_m933_d1.WIKA\" rel=\"external\" target=\"_blank\">All-Welded System <\/a>(AWS) specifically for alkylation units that use hydrofluoric acid.<\/p>\n<p>In these 4.5-inch XSEL\u00ae process gauges, the <a href=\"https:\/\/www.wika.com\/en-us\/lp_bourdon_tube_pressure_gauge.WIKA\" rel=\"external\" target=\"_blank\">Bourdon tube<\/a> and all wetted and non-wetted diaphragm seal parts are made of Monel\u00ae 400. The diaphragm seal is back-welded to a process gauge to eliminate potential leak paths. An InSight \u2122 Glow dial face improves visibility in low-light areas. The system comes in a yellow or red thermoplastic case to differentiate it from other instrumentation not in contact with HF.<\/p>\n<p>For added protection, the seal can be coated with an acid detecting paint that turns from yellow to red when there is a leak. Both the dry and the liquid-filled versions support EPA requirements for dual containment.<\/p>\n<h2>Extra Protection for Alkylation Units<\/h2>\n\n      <div class=\"wp-caption alignright\" style=\"max-width:179px;\"><img loading=\"lazy\" decoding=\"async\" class=\"size-ArticleFeatured wp-image-12700\" src=\"https:\/\/blog.wika.com\/us\/\/files\/2016\/10\/dms34_de_de_82952-171x471.png\" alt=\"Diaphragm monitoring system\" width=\"171\" height=\"471\" srcset=\"https:\/\/blog.wika.com\/us\/files\/2016\/10\/dms34_de_de_82952.png 171w, https:\/\/blog.wika.com\/us\/files\/2016\/10\/dms34_de_de_82952-54x150.png 54w\" sizes=\"auto, (max-width: 171px) 100vw, 171px\" \/><p class=\"wp-caption-text\">Model DMS34<br \/>\ndiaphragm monitoring system with threaded connection<\/p><\/div>\n    \n<p>For an additional layer of safety, WIKA offers a\u00a0<a href=\"https:\/\/www.wika.com\/en-us\/dms34.WIKA\" rel=\"external\" target=\"_blank\">Diaphragm Monitoring System <\/a>(DMS). This patented design features two diaphragm seals with a vacuum in between. A pressure transmitter, switch, or gauge monitors this vacuum. If the primary seal is breached, the DMS gives a visual, acoustic, or electrical warning that the vacuum is compromised. The still-intact secondary diaphragm prevents the release of the hazardous media into the environment, ensuring operator and plant safety.<\/p>\n<p>The DMS can be mounted directly into the process or via a capillary line. A cooling tower can be added between the diaphragm and the measuring instrument.<\/p>\n<p>Cheaper process gauges can adequately monitor pressure in an HF alkylation unit. But in the longer run, those instruments will corrode and become a source of dangerous emissions and leaks. WIKA\u2019s All-Welded Systems for hydrofluoric acid and the DMS\u2019s double-diaphragm design provide the safety and reliability modern refineries need. Contact our petrochemical specialists to find out more about WIKA\u2019s high-quality instruments and customer service.<\/p>\n<div style=\"width: 100%;float: left\"><a class=\"button white\" style=\"float: right\" href=\"https:\/\/www.wika.com\/en-us\/contact.WIKA\" rel=\"external\" target=\"_blank\"><span>Contact Us<\/span><\/a><\/div>\n<h3><strong>Products in this post:<\/strong><\/h3>\n<h3><span><\/span>\u2022 <a href=\"https:\/\/www.wika.com\/en-us\/dms34.WIKA\" rel=\"external\" target=\"_blank\">Model DMS34 Diaphragm Monitoring System<\/a><\/h3>\n<h3>\u00a0<\/h3>\n","protected":false},"excerpt":{"rendered":"<p>Alkylation units use very strong catalysts, such as hydrofluoric acid, to produce the components for high-octane gasoline. That\u2019s why refineries need process gauges and other pressure instruments that can withstand highly corrosive environments. Petroleum refineries rely on alkylation units to produce higher-grade and, therefore, higher-value products. After a fluidized catalytic cracking (FCC) unit transforms heavy [&hellip;]<\/p>\n","protected":false},"author":279,"featured_media":12705,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5],"tags":[407,633,703,411,733],"class_list":["post-1518","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowhow","tag-all-welded-system","tag-diaphragm-monitoring-system","tag-oil-and-gas","tag-pressure-gauges","tag-refinery"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>HF Alkylation Units for Corrosion Resistant Process Gauge- WIKA blog<\/title>\n<meta name=\"description\" content=\"HF alkylation units work with powerful acids. Refineries need high-quality anti corrosion process gauges to monitor emissions and leaks.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HF Alkylation Units for Corrosion Resistant Process Gauge- WIKA blog\" \/>\n<meta property=\"og:description\" content=\"HF alkylation units work with powerful acids. Refineries need high-quality anti corrosion process gauges to monitor emissions and leaks.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/us\/files\/2016\/10\/wika-diaphragm-monitoring-system.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Chi-Che Ma\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Chi-Che Ma\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/\"},\"author\":{\"name\":\"Chi-Che Ma\",\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/a68c26d4543eaf8c6f9043171c7b7639\"},\"headline\":\"HF Alkylation Units: Anti Corrosion Process Gauges to Prevent Leaks\",\"datePublished\":\"2019-12-19T15:30:13+00:00\",\"dateModified\":\"2025-05-15T14:40:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/\"},\"wordCount\":522,\"commentCount\":1,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/us\/files\/2016\/10\/wika-diaphragm-monitoring-system.jpeg\",\"keywords\":[\"All-Welded System\",\"Diaphragm Monitoring System\",\"oil and gas\",\"Pressure Gauges\",\"refinery\"],\"articleSection\":[\"Know-how\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/\",\"url\":\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/\",\"name\":\"HF Alkylation Units for Corrosion Resistant Process Gauge- WIKA blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/us\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/us\/files\/2016\/10\/wika-diaphragm-monitoring-system.jpeg\",\"datePublished\":\"2019-12-19T15:30:13+00:00\",\"dateModified\":\"2025-05-15T14:40:23+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/a68c26d4543eaf8c6f9043171c7b7639\"},\"description\":\"HF alkylation units work with powerful acids. Refineries need high-quality anti corrosion process gauges to monitor emissions and leaks.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/us\/files\/2016\/10\/wika-diaphragm-monitoring-system.jpeg\",\"contentUrl\":\"https:\/\/blog.wika.com\/us\/files\/2016\/10\/wika-diaphragm-monitoring-system.jpeg\",\"width\":1280,\"height\":720},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.wika.com\/us\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HF Alkylation Units: Anti Corrosion Process Gauges to Prevent Leaks\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/us\/#website\",\"url\":\"https:\/\/blog.wika.com\/us\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/us\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/a68c26d4543eaf8c6f9043171c7b7639\",\"name\":\"Chi-Che Ma\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.wika.com\/us\/files\/2023\/08\/chi-chema_blog-120x120.jpg\",\"url\":\"https:\/\/blog.wika.com\/us\/files\/2023\/08\/chi-chema_blog-120x120.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/us\/files\/2023\/08\/chi-chema_blog-120x120.jpg\",\"caption\":\"Chi-Che Ma\"},\"url\":\"https:\/\/blog.wika.com\/us\/author\/chichema\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"HF Alkylation Units for Corrosion Resistant Process Gauge- WIKA blog","description":"HF alkylation units work with powerful acids. Refineries need high-quality anti corrosion process gauges to monitor emissions and leaks.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/","og_locale":"en_US","og_type":"article","og_title":"HF Alkylation Units for Corrosion Resistant Process Gauge- WIKA blog","og_description":"HF alkylation units work with powerful acids. Refineries need high-quality anti corrosion process gauges to monitor emissions and leaks.","og_url":"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/","og_site_name":"WIKA blog","og_image":[{"width":1280,"height":720,"url":"https:\/\/blog.wika.com\/us\/files\/2016\/10\/wika-diaphragm-monitoring-system.jpeg","type":"image\/jpeg"}],"author":"Chi-Che Ma","twitter_misc":{"Written by":"Chi-Che Ma","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/"},"author":{"name":"Chi-Che Ma","@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/a68c26d4543eaf8c6f9043171c7b7639"},"headline":"HF Alkylation Units: Anti Corrosion Process Gauges to Prevent Leaks","datePublished":"2019-12-19T15:30:13+00:00","dateModified":"2025-05-15T14:40:23+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/"},"wordCount":522,"commentCount":1,"image":{"@id":"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/us\/files\/2016\/10\/wika-diaphragm-monitoring-system.jpeg","keywords":["All-Welded System","Diaphragm Monitoring System","oil and gas","Pressure Gauges","refinery"],"articleSection":["Know-how"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/","url":"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/","name":"HF Alkylation Units for Corrosion Resistant Process Gauge- WIKA blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/us\/files\/2016\/10\/wika-diaphragm-monitoring-system.jpeg","datePublished":"2019-12-19T15:30:13+00:00","dateModified":"2025-05-15T14:40:23+00:00","author":{"@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/a68c26d4543eaf8c6f9043171c7b7639"},"description":"HF alkylation units work with powerful acids. Refineries need high-quality anti corrosion process gauges to monitor emissions and leaks.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#primaryimage","url":"https:\/\/blog.wika.com\/us\/files\/2016\/10\/wika-diaphragm-monitoring-system.jpeg","contentUrl":"https:\/\/blog.wika.com\/us\/files\/2016\/10\/wika-diaphragm-monitoring-system.jpeg","width":1280,"height":720},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/us\/knowhow\/hf-alkylation-units-prevent-dangerous-emissions-leaks\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/us\/"},{"@type":"ListItem","position":2,"name":"HF Alkylation Units: Anti Corrosion Process Gauges to Prevent Leaks"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/us\/#website","url":"https:\/\/blog.wika.com\/us\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/a68c26d4543eaf8c6f9043171c7b7639","name":"Chi-Che Ma","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.wika.com\/us\/files\/2023\/08\/chi-chema_blog-120x120.jpg","url":"https:\/\/blog.wika.com\/us\/files\/2023\/08\/chi-chema_blog-120x120.jpg","contentUrl":"https:\/\/blog.wika.com\/us\/files\/2023\/08\/chi-chema_blog-120x120.jpg","caption":"Chi-Che Ma"},"url":"https:\/\/blog.wika.com\/us\/author\/chichema\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/1518","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/users\/279"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/comments?post=1518"}],"version-history":[{"count":16,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/1518\/revisions"}],"predecessor-version":[{"id":18557,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/1518\/revisions\/18557"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/media\/12705"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/media?parent=1518"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/categories?post=1518"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/tags?post=1518"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}