{"id":1699,"date":"2017-06-06T17:15:58","date_gmt":"2017-06-06T15:15:58","guid":{"rendered":"http:\/\/blog.wika.com\/us\/\/?p=1699"},"modified":"2025-02-03T14:39:40","modified_gmt":"2025-02-03T19:39:40","slug":"bottom-rtd-sensor-reading-delays","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/","title":{"rendered":"Getting to the Bottom of a RTD Sensor Reading Delay"},"content":{"rendered":"<p>The process engineers at a major chemical manufacturer were stumped. They were regularly getting very poor response times from their process temperature sensors and simply could not figure out why. The response times to temperature changes were consistently close to 30 minutes longer than they should have been, but all of the system diagnostic tests showed there was no problem with the sensing instruments. After checking everything they could think of, the engineers contacted the provider of the temperature sensors and explained the problem.\u00a0However, technical staff of\u00a0that well-known instrument maker could not explain the unusual lag in their resistance temperature detector-type sensors. Keep in mind that temperature control is essential in almost all chemical processes, and a half-hour lag is a major issue. Inaccurate temperature control can lead to expensive problems, such as spoiled batches, or, in a worst-case scenario, even lead to fugitive emissions or process leaks through damaged seals in valves, instruments, and equipment.<\/p>\n<h2>Poor Contact to Blame for Lagging Temperature Readings<\/h2>\n<p>In search of a solution, the lead Control System Engineer at the plant consulted with a temperature specialist from WIKA Instrument. Within just a few minutes of conversation, WIKA\u2019s temperature specialist was pretty sure he had a good idea what the problem was. He had heard of this lag problem before: It was almost always related to the sensor tip not actually making contact with the media to be measured. It is generally necessary to have direct contact between the sensor tip and the process media pipe or storage tank wall in order to get a near-immediate temperature reading. Any kind of a gap between the tip and the surface to be measured will result in a lag before the heat is transferred to the sensor. After a plant walkthrough, the temperature specialist\u2019s initial suspicion was confirmed. The temperature sensors weren\u2019t long enough to touch the bottom surface of the process wells. This was causing the reading delay.<\/p>\n<h2>RTDs with Spring-load Assembly Resolve Delays<\/h2>\n\n      <div class=\"wp-caption alignright\" style=\"max-width:198px;\"><a href=\"http:\/\/blog.wika.com\/us\/\/files\/2017\/06\/Screen-Shot-2017-06-06-at-11.08.23-AM.png\"><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/us\/\/files\/2017\/06\/Screen-Shot-2017-06-06-at-11.08.23-AM-190x300.png\" alt=\"WIKA Model TR-10 Industrial RTD Assembly\" \/><\/a><p class=\"wp-caption-text\">WIKA Model TR-10 Industrial RTD Assembly<\/p><\/div>\n    \n<p>WIKA\u2019s temperature engineering team suggested that a <a href=\"https:\/\/www.wika.com\/en-us\/tr10_2.WIKA\" rel=\"external\" target=\"_blank\">spring-loaded RTD (resistance temperature detector) assembly<\/a> was the best way to make sure the sensor tip reached the inside bottom of extra-deep thermowells. WIKA provided the maintenance team at the plant with three sample spring-loaded sensor assemblies, which passed all tests and interfaced seamlessly with the plant\u2019s distributed control sensors (DCS). The new temperature sensors have performed flawlessly, plant management is happy and WIKA has another satisfied customer who has already expressed an interest in future temperature sensor business.<\/p>\n<p>[contact-form-7 id=&#8221;14552&#8243; title=&#8221;Blog Contact Form&#8221;]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The process engineers at a major chemical manufacturer were stumped. They were regularly getting very poor response times from their process temperature sensors and simply could not figure out why. The response times to temperature changes were consistently close to 30 minutes longer than they should have been, but all of the system diagnostic tests [&hellip;]<\/p>\n","protected":false},"author":398,"featured_media":1702,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221],"tags":[584,324,437,820],"class_list":["post-1699","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-temperature-products","tag-rtd","tag-temperature","tag-temperature-measurement","tag-temperature-monitoring"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Causes of RTD Sensor Delays and Problems - WIKA blog<\/title>\n<meta name=\"description\" content=\"The process engineers at a major chemical manufacturer were stumped. They were regularly getting very poor response times from their process temperature sensors and simply could not figure out why.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Causes of RTD Sensor Delays and Problems - WIKA blog\" \/>\n<meta property=\"og:description\" content=\"The process engineers at a major chemical manufacturer were stumped. They were regularly getting very poor response times from their process temperature sensors and simply could not figure out why.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/us\/files\/2017\/06\/rtd-assembly_tr10_2_67146.png\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"700\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Gabriel Gonzales\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Gabriel Gonzales\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/\"},\"author\":{\"name\":\"Gabriel Gonzales\",\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/e34259b854b19ecb70ef67d7cd06d280\"},\"headline\":\"Getting to the Bottom of a RTD Sensor Reading Delay\",\"datePublished\":\"2017-06-06T15:15:58+00:00\",\"dateModified\":\"2025-02-03T19:39:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/\"},\"wordCount\":449,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/us\/files\/2017\/06\/rtd-assembly_tr10_2_67146.png\",\"keywords\":[\"RTD\",\"Temperature\",\"temperature measurement\",\"temperature monitoring\"],\"articleSection\":[\"Temperature\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/\",\"url\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/\",\"name\":\"Causes of RTD Sensor Delays and Problems - WIKA blog\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/us\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/us\/files\/2017\/06\/rtd-assembly_tr10_2_67146.png\",\"datePublished\":\"2017-06-06T15:15:58+00:00\",\"dateModified\":\"2025-02-03T19:39:40+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/e34259b854b19ecb70ef67d7cd06d280\"},\"description\":\"The process engineers at a major chemical manufacturer were stumped. They were regularly getting very poor response times from their process temperature sensors and simply could not figure out why.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/us\/files\/2017\/06\/rtd-assembly_tr10_2_67146.png\",\"contentUrl\":\"https:\/\/blog.wika.com\/us\/files\/2017\/06\/rtd-assembly_tr10_2_67146.png\",\"width\":700,\"height\":700,\"caption\":\"Model TR10 RTD sensor\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.wika.com\/us\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Getting to the Bottom of a RTD Sensor Reading Delay\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/us\/#website\",\"url\":\"https:\/\/blog.wika.com\/us\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/us\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/e34259b854b19ecb70ef67d7cd06d280\",\"name\":\"Gabriel Gonzales\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.wika.com\/us\/files\/2025\/02\/gabrielgonzales117-3-120x120.jpg\",\"url\":\"https:\/\/blog.wika.com\/us\/files\/2025\/02\/gabrielgonzales117-3-120x120.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/us\/files\/2025\/02\/gabrielgonzales117-3-120x120.jpg\",\"caption\":\"Gabriel Gonzales\"},\"description\":\"I have been with WIKA Group since 2005 while steadily advancing through a variety of technical and sales-oriented roles, honing expertise in temperature and pressure products for the oil and gas industry. Over the years, I have developed innovative sales strategies, led product specialists, and engineered technological solutions to meet client needs. In 2023, I assumed the role of Product Manager \u2013 ETM Process Instrumentation, spearheading initiatives to enhance product management and drive market growth. I earned a degree in Instrumentation and Process Technology, AAS from San Jacinto College, equipping myself with the knowledge and skills to excel in industrial marketing and engineering.\",\"url\":\"https:\/\/blog.wika.com\/us\/author\/ggonzales\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Causes of RTD Sensor Delays and Problems - WIKA blog","description":"The process engineers at a major chemical manufacturer were stumped. They were regularly getting very poor response times from their process temperature sensors and simply could not figure out why.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/","og_locale":"en_US","og_type":"article","og_title":"Causes of RTD Sensor Delays and Problems - WIKA blog","og_description":"The process engineers at a major chemical manufacturer were stumped. They were regularly getting very poor response times from their process temperature sensors and simply could not figure out why.","og_url":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/","og_site_name":"WIKA blog","og_image":[{"width":700,"height":700,"url":"https:\/\/blog.wika.com\/us\/files\/2017\/06\/rtd-assembly_tr10_2_67146.png","type":"image\/png"}],"author":"Gabriel Gonzales","twitter_misc":{"Written by":"Gabriel Gonzales","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/"},"author":{"name":"Gabriel Gonzales","@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/e34259b854b19ecb70ef67d7cd06d280"},"headline":"Getting to the Bottom of a RTD Sensor Reading Delay","datePublished":"2017-06-06T15:15:58+00:00","dateModified":"2025-02-03T19:39:40+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/"},"wordCount":449,"commentCount":0,"image":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/us\/files\/2017\/06\/rtd-assembly_tr10_2_67146.png","keywords":["RTD","Temperature","temperature measurement","temperature monitoring"],"articleSection":["Temperature"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/","url":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/","name":"Causes of RTD Sensor Delays and Problems - WIKA blog","isPartOf":{"@id":"https:\/\/blog.wika.com\/us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/us\/files\/2017\/06\/rtd-assembly_tr10_2_67146.png","datePublished":"2017-06-06T15:15:58+00:00","dateModified":"2025-02-03T19:39:40+00:00","author":{"@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/e34259b854b19ecb70ef67d7cd06d280"},"description":"The process engineers at a major chemical manufacturer were stumped. They were regularly getting very poor response times from their process temperature sensors and simply could not figure out why.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#primaryimage","url":"https:\/\/blog.wika.com\/us\/files\/2017\/06\/rtd-assembly_tr10_2_67146.png","contentUrl":"https:\/\/blog.wika.com\/us\/files\/2017\/06\/rtd-assembly_tr10_2_67146.png","width":700,"height":700,"caption":"Model TR10 RTD sensor"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/bottom-rtd-sensor-reading-delays\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/us\/"},{"@type":"ListItem","position":2,"name":"Getting to the Bottom of a RTD Sensor Reading Delay"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/us\/#website","url":"https:\/\/blog.wika.com\/us\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/e34259b854b19ecb70ef67d7cd06d280","name":"Gabriel Gonzales","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.wika.com\/us\/files\/2025\/02\/gabrielgonzales117-3-120x120.jpg","url":"https:\/\/blog.wika.com\/us\/files\/2025\/02\/gabrielgonzales117-3-120x120.jpg","contentUrl":"https:\/\/blog.wika.com\/us\/files\/2025\/02\/gabrielgonzales117-3-120x120.jpg","caption":"Gabriel Gonzales"},"description":"I have been with WIKA Group since 2005 while steadily advancing through a variety of technical and sales-oriented roles, honing expertise in temperature and pressure products for the oil and gas industry. Over the years, I have developed innovative sales strategies, led product specialists, and engineered technological solutions to meet client needs. In 2023, I assumed the role of Product Manager \u2013 ETM Process Instrumentation, spearheading initiatives to enhance product management and drive market growth. I earned a degree in Instrumentation and Process Technology, AAS from San Jacinto College, equipping myself with the knowledge and skills to excel in industrial marketing and engineering.","url":"https:\/\/blog.wika.com\/us\/author\/ggonzales\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/1699","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/users\/398"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/comments?post=1699"}],"version-history":[{"count":7,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/1699\/revisions"}],"predecessor-version":[{"id":16733,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/1699\/revisions\/16733"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/media\/1702"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/media?parent=1699"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/categories?post=1699"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/tags?post=1699"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}