{"id":19674,"date":"2026-09-30T14:34:25","date_gmt":"2026-09-30T19:34:25","guid":{"rendered":"https:\/\/blog.wika.com\/us\/?p=19674"},"modified":"2026-09-30T14:34:25","modified_gmt":"2026-09-30T19:34:25","slug":"non-contact-radar-level-sensors-solve-industrial-measurement-problems","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/","title":{"rendered":"How Non-Contact Radar Level Sensors Solve Tough Industrial Measurement Challenges"},"content":{"rendered":"<p style=\"font-weight: 400\"><strong>Radar is a smart way to accurately and continuously monitor the level of liquids or solids. For manufacturers, process industries, and OEMs, non-contact radar level sensors overcome the toughest measurement challenges.<\/strong><\/p>\n<p style=\"font-weight: 400\">The marketplace offers a wide range of instruments for measuring the level of liquids and solids, then transmitting that information to a control system. One of the most accurate and reliable technologies for level sensing available today is radar. It\u2019s also highly flexible. Not only is radar indifferent to dust, moisture, vibration,\u00a0temperature, and pressure, its contactless nature makes it the ideal method for measuring highly viscous or abrasive media, bulk solids, and other challenging materials. Non-contact also means no moving parts, no wear and tear, and no risk of contaminating the process media. And of course, radar sensors measure distances as well.<\/p>\n<h2>How do non-contact radar level transmitters work?<\/h2>\n\n      <div class=\"wp-caption alignright\" style=\"max-width:358px;\"><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/us\/files\/2026\/09\/radar-level-sensor-495x471.jpg\" \/><p class=\"wp-caption-text\">Non-contact radar level sensing<\/p><\/div>\n    \n<p style=\"font-weight: 400\">In simple terms, a radar-based sensor determines level by measuring the time it takes for electromagnetic waves to travel from the transmitter\u2019s antenna and back, calculating the distance between it and a reflected surface, and then subtracting that distance from the known height of the vessel.<\/p>\n<ol>\n<li>Mounted at the top of a vessel, the sensor\u2019s antenna directs either high-frequency pulses or frequency modulated continuous waves (FMCW) toward the liquid or solid.<\/li>\n<li>The radar waves travel freely at approximately the speed of light, reflect off the media, and are picked up by the antenna.<\/li>\n<li>The sensor uses FMCW radar technology to continuously analyze the frequency differences between transmitted and reflected signals, enabling precise distance measurement to the product surface<\/li>\n<li>The sensor then determines level by subtracting that measured distance from the known distance between the sensor antenna and the vessel floor.<\/li>\n<\/ol>\n<p style=\"font-weight: 400\">Non-contact radar level transmitters work best in simple tanks but can be adapted for use with complex vessel geometries.<\/p>\n<h2>What are the advantages of using radar level sensors?<\/h2>\n<p>Non-contact radar level sensors offer numerous advantages over level measuring instruments based on floats, reed contacts, optoelectronics, ultrasound, guided wave radar, hydrostatic pressure, vibrating tuning fork, or other technologies.<\/p>\n<table style=\"width: 98.325386%\">\n<tbody>\n<tr>\n<td style=\"width: 26.261911%\" width=\"162\">\n<p><strong>Accuracy in challenging measurement conditions<\/strong><\/p>\n<\/td>\n<td style=\"width: 124.28956%\" width=\"378\">\n<p>\u2022 dusty environments<br \/>\n\u2022 vibration and shock<br \/>\n\u2022 tilting<br \/>\n\u2022 water vapors and oil mists<br \/>\n\u2022 foaming media<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 26.261911%\" width=\"162\">\n<p><strong>High versatility<\/strong><\/p>\n<\/td>\n<td style=\"width: 124.28956%\" width=\"378\">\n<p>\u2022 wide range of liquids, including ones that are corrosive, abrasive, <br \/>\nand highly viscous<br \/>\n\u2022 wide range of solids, from powders and pellets to fibers and bulk materials<br \/>\n\u2022 can also measure distance<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 26.261911%\" width=\"162\">\n<p><strong>Compact size<\/strong><\/p>\n<\/td>\n<td style=\"width: 124.28956%\" width=\"378\">\n<p>\u2022 easy to transport and store<br \/>\n\u2022 can be mounted in limited spaces<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 26.261911%\" width=\"162\">\n<p><strong>Non-invasive mounting<\/strong><\/p>\n<\/td>\n<td style=\"width: 124.28956%\" width=\"378\">\n<p>\u2022 can be installed outside plastic and other non-metallic <br \/>\n(non-conductive) tanks without penetrating the vessel wall<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>Radar vs. ultrasonic level measurement<\/strong><\/h3>\n<p>Ultrasonic level measurement is also continuous, non-contact, and maintenance-free, and the working principle is like that of radar level measurement except sound waves are transmitted rather than electromagnetic waves. However, ultrasound signals are not as robust as radar signals.<\/p>\n<p>Ultrasonic level sensors work well in simple, calm environments. But if a vessel contains foam, vapors, condensation, oil mists, or dust, those elements scatter or absorb the sound waves. The result is inaccurate, inconsistent, or false level readings. And unlike radar waves, ultrasound waves do not readily pass through plastic, fiberglass, and other non-conductive materials.<\/p>\n<h2><strong>What are the limitations of radar level sensors?<\/strong><\/h2>\n<p>While contact-less radar sensors are highly versatile and accurate, they are not the optimal level measurement solution for every operating conditions or applications. This is because radar level sensors:<\/p>\n<ul>\n<li>Require a power source and wiring.<\/li>\n<li>Are not suited for measuring the level of low dielectric (&lt;2) materials, which would allow electromagnetic waves to pass through rather than bounce off.<\/li>\n<li>Have difficulty with extremely complex tank internals, such as agitators or other dense obstructions that cause false echoes.<\/li>\n<li>Denser and more robust foam<\/li>\n<\/ul>\n<p><strong><em>This two-part series continues with a detailed look at WIKA\u2019s ILT radar level sensors for industrial applications. <\/em><\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Radar is a smart way to accurately and continuously monitor the level of liquids or solids. For manufacturers, process industries, and OEMs, non-contact radar level sensors overcome the toughest measurement challenges. The marketplace offers a wide range of instruments for measuring the level of liquids and solids, then transmitting that information to a control system. [&hellip;]<\/p>\n","protected":false},"author":188,"featured_media":19682,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5,223],"tags":[436,799],"class_list":["post-19674","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-knowhow","category-level-products","tag-level-measurement","tag-level-monitoring"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Non-Contact Radar Level Sensors Solve Industrial Measurement Problems<\/title>\n<meta name=\"description\" content=\"Non-contact radar level sensors handle corrosive liquids, solids, high heat, and tight spaces where contact level measurement methods fail. Learn how radar technology solves your toughest level sensing challenges.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Non-Contact Radar Level Sensors Solve Industrial Measurement Problems\" \/>\n<meta property=\"og:description\" content=\"Non-contact radar level sensors handle corrosive liquids, solids, high heat, and tight spaces where contact level measurement methods fail. Learn how radar technology solves your toughest level sensing challenges.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/us\/files\/2026\/09\/non-contact-radar-sensing_featured-image-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"470\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Jeff Placek\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Jeff Placek\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/products\\\/level-products\\\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/products\\\/level-products\\\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\\\/\"},\"author\":{\"name\":\"Jeff Placek\",\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/#\\\/schema\\\/person\\\/8d2cbbabfb4ec43b285229fb14d04066\"},\"headline\":\"How Non-Contact Radar Level Sensors Solve Tough Industrial Measurement Challenges\",\"datePublished\":\"2026-09-30T19:34:25+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/products\\\/level-products\\\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\\\/\"},\"wordCount\":649,\"image\":{\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/products\\\/level-products\\\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/files\\\/2026\\\/09\\\/non-contact-radar-sensing_featured-image-1.png\",\"keywords\":[\"Level Measurement\",\"level monitoring\"],\"articleSection\":[\"Know-how\",\"Level\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/products\\\/level-products\\\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\\\/\",\"url\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/products\\\/level-products\\\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\\\/\",\"name\":\"Non-Contact Radar Level Sensors Solve Industrial Measurement Problems\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/products\\\/level-products\\\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/products\\\/level-products\\\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/files\\\/2026\\\/09\\\/non-contact-radar-sensing_featured-image-1.png\",\"datePublished\":\"2026-09-30T19:34:25+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/#\\\/schema\\\/person\\\/8d2cbbabfb4ec43b285229fb14d04066\"},\"description\":\"Non-contact radar level sensors handle corrosive liquids, solids, high heat, and tight spaces where contact level measurement methods fail. Learn how radar technology solves your toughest level sensing challenges.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/products\\\/level-products\\\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.wika.com\\\/us\\\/products\\\/level-products\\\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/products\\\/level-products\\\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/files\\\/2026\\\/09\\\/non-contact-radar-sensing_featured-image-1.png\",\"contentUrl\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/files\\\/2026\\\/09\\\/non-contact-radar-sensing_featured-image-1.png\",\"width\":838,\"height\":470,\"caption\":\"How non-contact radar level sensors solve tough industrial measurement challenges\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/products\\\/level-products\\\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How Non-Contact Radar Level Sensors Solve Tough Industrial Measurement Challenges\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/#website\",\"url\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/#\\\/schema\\\/person\\\/8d2cbbabfb4ec43b285229fb14d04066\",\"name\":\"Jeff Placek\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/files\\\/2023\\\/08\\\/jeffplacek2022_blog-120x120.jpg\",\"url\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/files\\\/2023\\\/08\\\/jeffplacek2022_blog-120x120.jpg\",\"contentUrl\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/files\\\/2023\\\/08\\\/jeffplacek2022_blog-120x120.jpg\",\"caption\":\"Jeff Placek\"},\"url\":\"https:\\\/\\\/blog.wika.com\\\/us\\\/author\\\/jplacek\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Non-Contact Radar Level Sensors Solve Industrial Measurement Problems","description":"Non-contact radar level sensors handle corrosive liquids, solids, high heat, and tight spaces where contact level measurement methods fail. Learn how radar technology solves your toughest level sensing challenges.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/","og_locale":"en_US","og_type":"article","og_title":"Non-Contact Radar Level Sensors Solve Industrial Measurement Problems","og_description":"Non-contact radar level sensors handle corrosive liquids, solids, high heat, and tight spaces where contact level measurement methods fail. Learn how radar technology solves your toughest level sensing challenges.","og_url":"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/","og_site_name":"WIKA blog","og_image":[{"width":838,"height":470,"url":"https:\/\/blog.wika.com\/us\/files\/2026\/09\/non-contact-radar-sensing_featured-image-1.png","type":"image\/png"}],"author":"Jeff Placek","twitter_misc":{"Written by":"Jeff Placek","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/"},"author":{"name":"Jeff Placek","@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/8d2cbbabfb4ec43b285229fb14d04066"},"headline":"How Non-Contact Radar Level Sensors Solve Tough Industrial Measurement Challenges","datePublished":"2026-09-30T19:34:25+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/"},"wordCount":649,"image":{"@id":"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/us\/files\/2026\/09\/non-contact-radar-sensing_featured-image-1.png","keywords":["Level Measurement","level monitoring"],"articleSection":["Know-how","Level"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/","url":"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/","name":"Non-Contact Radar Level Sensors Solve Industrial Measurement Problems","isPartOf":{"@id":"https:\/\/blog.wika.com\/us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/us\/files\/2026\/09\/non-contact-radar-sensing_featured-image-1.png","datePublished":"2026-09-30T19:34:25+00:00","author":{"@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/8d2cbbabfb4ec43b285229fb14d04066"},"description":"Non-contact radar level sensors handle corrosive liquids, solids, high heat, and tight spaces where contact level measurement methods fail. Learn how radar technology solves your toughest level sensing challenges.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/#primaryimage","url":"https:\/\/blog.wika.com\/us\/files\/2026\/09\/non-contact-radar-sensing_featured-image-1.png","contentUrl":"https:\/\/blog.wika.com\/us\/files\/2026\/09\/non-contact-radar-sensing_featured-image-1.png","width":838,"height":470,"caption":"How non-contact radar level sensors solve tough industrial measurement challenges"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/us\/products\/level-products\/non-contact-radar-level-sensors-solve-industrial-measurement-problems\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/us\/"},{"@type":"ListItem","position":2,"name":"How Non-Contact Radar Level Sensors Solve Tough Industrial Measurement Challenges"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/us\/#website","url":"https:\/\/blog.wika.com\/us\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/8d2cbbabfb4ec43b285229fb14d04066","name":"Jeff Placek","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.wika.com\/us\/files\/2023\/08\/jeffplacek2022_blog-120x120.jpg","url":"https:\/\/blog.wika.com\/us\/files\/2023\/08\/jeffplacek2022_blog-120x120.jpg","contentUrl":"https:\/\/blog.wika.com\/us\/files\/2023\/08\/jeffplacek2022_blog-120x120.jpg","caption":"Jeff Placek"},"url":"https:\/\/blog.wika.com\/us\/author\/jplacek\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/19674","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/users\/188"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/comments?post=19674"}],"version-history":[{"count":5,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/19674\/revisions"}],"predecessor-version":[{"id":19681,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/19674\/revisions\/19681"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/media\/19682"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/media?parent=19674"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/categories?post=19674"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/tags?post=19674"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}