{"id":9873,"date":"2018-08-01T21:27:02","date_gmt":"2018-08-02T02:27:02","guid":{"rendered":"https:\/\/blog.wika.com\/us\/\/?p=9873"},"modified":"2025-11-12T10:57:44","modified_gmt":"2025-11-12T15:57:44","slug":"pt100-sensors-high-vibration","status":"publish","type":"post","link":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/","title":{"rendered":"For High-Vibration Applications, Use Rugged Pt100 Sensors"},"content":{"rendered":"<p><strong>Turbines, pumps, and compressors produce significant vibrations, which can lead temperature measurement instruments to give incorrect readings and cause premature sensor failure. Pt100 RTDs can withstand several times more vibration than standard elements, making them one of the best temperature sensors for high-vibration applications in refining, petrochemical, and power &amp; energy industries.<\/strong><\/p>\n<p>Industrial and mobile machines vibrate when they work. It\u2019s normal. Most measurement instruments are built to withstand some shaking. Problems can occur, however, when the vibration is significant. This is the case in power generation and other industries that rely on massive turbines, compressors, and pumps for critical applications.<\/p>\n<p>In temperature sensors, high vibrations can weaken the wires and insulation, leading to intermittent and\/or incorrect measurements. Extreme vibrations also shorten the life of temperature sensors, which means frequent downtimes and higher operating costs.<\/p>\n<h2>What\u2019s Shaking: Types of Vibrations<\/h2>\n<p>When motors, pumps, and compressors are in operation, they shake. This is mechanical vibration. Engines and turbines also generate acoustic vibrations that turn into structural vibrations when they hit a thermocouple or RTD (resistance temperature detector, also called a resistance thermometer).\u00a0Fluid flow is another source of structural vibration.<\/p>\n<p>The damage caused by vibrations is proportional to the:<\/p>\n<ol>\n<li><strong>Amplitude\u00a0<\/strong>of the vibration \u2014 the force applied to the object.<\/li>\n<li><strong>Frequency\u00a0<\/strong>of the vibration \u2014 the rate of the back and forth movement.<\/li>\n<\/ol>\n<p>In power plants, common producers of vibrations include boiler feedwater pumps, condensate pumps, steam and gas turbines, and generators.<\/p>\n<h2>How Vibrations Affect Temperature Sensors<\/h2>\n<p>The main effect of vibrations on temperature measurement sensors is mechanical stress. In thermocouples, vibrations produce material fatigue. This, in turn, causes insulation failure and short circuits that result in inaccurate and\/or intermittent readings. As for <a href=\"http:\/\/blog.wika.com\/us\/\/products\/temperature-products\/need-know-industrial-resistance-thermometers\/\">industrial resistance thermometers<\/a>, the platinum wires of wire-wound RTDs are very thin and break easily when subject to vibrations. Damaged RTDs generate noise in the output signal, give irregular temperature measurements, and, ultimately, open the circuit. Thin-film RTDs, where a thin layer of platinum is deposited on a ceramic base and then encased in glass, are much more resistant to vibrations.<\/p>\n<h2>Pt100 Sensors in High-Vibration Applications<\/h2>\n<p>Thin-film Pt100 RTDs sit at the sweet spot of accuracy, cost effectiveness, and vibration resistance. WIKA USA\u2019s <a href=\"https:\/\/www.wika.com\/en-us\/lp_pt100_pt1000.WIKA\" rel=\"external\" target=\"_blank\">Pt100 resistance thermometers\u00a0<\/a>are rugged, able to withstand several times more vibration than standard temperature elements. They work very well in applications affected by vibrations from turbines, pumps, compressors, and other such heavy industrial equipment.<\/p>\n<p>The benefits of using WIKA\u2019s Pt100 sensors include:<\/p>\n<ul>\n<li>Minimal risk of sensor breakage due to vibrations and\/or impact<\/li>\n<li>Increased long-term reliability and stability<\/li>\n<li>High accuracy<\/li>\n<li>Fast response<\/li>\n<\/ul>\n<p>WIKA USA manufactures a wide range of resistance thermometers with either Pt100 or Pt1000 sensors. To find the ones that will offer the most accuracy and vibration resistance for your applications and budget, <a href=\"https:\/\/www.wika.com\/en-us\/contact.WIKA\" rel=\"external\" target=\"_blank\">contact WIKA today<\/a>.<\/p>\n<p>Click <a href=\"https:\/\/wika.pages.salesfusion.com\/2019-Hydropower-White-Paper-Gate\" rel=\"external\" target=\"_blank\">here<\/a> to download the white paper &#8220;Monitoring Safety &amp; Efficiency: The Importance of Measuring Level, Flow, Pressure, Temperature, and Force in Hydropower Plants&#8221;<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/blog.wika.com\/us\/\/files\/2019\/07\/shutterstock_52898251-resized-388x218.png\" alt=\"hydropower plant\" \/><\/figure>\n<div style=\"width: 100%;float: left\">\n<p style=\"margin: 0in;margin-left: .375in;font-family: Calibri;font-size: 11.0pt\">[contact-form-7 id=&#8221;14552&#8243; title=&#8221;Blog Contact Form&#8221;]<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Turbines, pumps, and compressors produce significant vibrations, which can lead temperature measurement instruments to give incorrect readings and cause premature sensor failure. Pt100 RTDs can withstand several times more vibration than standard elements, making them one of the best temperature sensors for high-vibration applications in refining, petrochemical, and power &amp; energy industries. Industrial and mobile [&hellip;]<\/p>\n","protected":false},"author":429,"featured_media":9878,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[221],"tags":[819,733,584,437,692,477],"class_list":["post-9873","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-temperature-products","tag-power-generation","tag-refinery","tag-rtd","tag-temperature-measurement","tag-temperature-sensor","tag-vibration"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Pt100 RTDs for High-Vibration Applications in Power Plants, Refineries<\/title>\n<meta name=\"description\" content=\"Vibrations can damage RTDs and thermocouples, and lead to incorrect temperature measurements, short circuits, and sensor failure. WIKA USA\u2019s Pt100 sensors minimize these risks, keeping costs and downtime under control in power plants, refineries, cement plants, steel mills and petrochemical plants.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Pt100 RTDs for High-Vibration Applications in Power Plants, Refineries\" \/>\n<meta property=\"og:description\" content=\"Vibrations can damage RTDs and thermocouples, and lead to incorrect temperature measurements, short circuits, and sensor failure. WIKA USA\u2019s Pt100 sensors minimize these risks, keeping costs and downtime under control in power plants, refineries, cement plants, steel mills and petrochemical plants.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/\" \/>\n<meta property=\"og:site_name\" content=\"WIKA blog\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.wika.com\/us\/files\/2018\/08\/high-vibration-temp-measurement_copyright-shutterstock_resized.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"838\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Chad Reinhard\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Chad Reinhard\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/\"},\"author\":{\"name\":\"Chad Reinhard\",\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/5459487bc00f1a51b7793a0ae24a8395\"},\"headline\":\"For High-Vibration Applications, Use Rugged Pt100 Sensors\",\"datePublished\":\"2018-08-02T02:27:02+00:00\",\"dateModified\":\"2025-11-12T15:57:44+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/\"},\"wordCount\":505,\"image\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/us\/files\/2018\/08\/high-vibration-temp-measurement_copyright-shutterstock_resized.jpg\",\"keywords\":[\"power generation\",\"refinery\",\"RTD\",\"temperature measurement\",\"temperature sensor\",\"vibration\"],\"articleSection\":[\"Temperature\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/\",\"url\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/\",\"name\":\"Pt100 RTDs for High-Vibration Applications in Power Plants, Refineries\",\"isPartOf\":{\"@id\":\"https:\/\/blog.wika.com\/us\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.wika.com\/us\/files\/2018\/08\/high-vibration-temp-measurement_copyright-shutterstock_resized.jpg\",\"datePublished\":\"2018-08-02T02:27:02+00:00\",\"dateModified\":\"2025-11-12T15:57:44+00:00\",\"author\":{\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/5459487bc00f1a51b7793a0ae24a8395\"},\"description\":\"Vibrations can damage RTDs and thermocouples, and lead to incorrect temperature measurements, short circuits, and sensor failure. WIKA USA\u2019s Pt100 sensors minimize these risks, keeping costs and downtime under control in power plants, refineries, cement plants, steel mills and petrochemical plants.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/#primaryimage\",\"url\":\"https:\/\/blog.wika.com\/us\/files\/2018\/08\/high-vibration-temp-measurement_copyright-shutterstock_resized.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/us\/files\/2018\/08\/high-vibration-temp-measurement_copyright-shutterstock_resized.jpg\",\"width\":838,\"height\":471,\"caption\":\"Vibrations can damage RTDs and thermocouples, and lead to incorrect temperature measurements, short circuits, and sensor failure. WIKA USA\u2019s rugged Pt100 sensors minimize these risks.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.wika.com\/us\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"For High-Vibration Applications, Use Rugged Pt100 Sensors\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.wika.com\/us\/#website\",\"url\":\"https:\/\/blog.wika.com\/us\/\",\"name\":\"WIKA blog\",\"description\":\"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.wika.com\/us\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.wika.com\/us\/#\/schema\/person\/5459487bc00f1a51b7793a0ae24a8395\",\"name\":\"Chad Reinhard\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.wika.com\/us\/files\/2025\/11\/wikajune2022_chad-reinhard_blog-120x120.jpg\",\"url\":\"https:\/\/blog.wika.com\/us\/files\/2025\/11\/wikajune2022_chad-reinhard_blog-120x120.jpg\",\"contentUrl\":\"https:\/\/blog.wika.com\/us\/files\/2025\/11\/wikajune2022_chad-reinhard_blog-120x120.jpg\",\"caption\":\"Chad Reinhard\"},\"description\":\"With over a decade of experience in industrial instrumentation and sales leadership, Chad currently serves as Senior Product Manager at WIKA Group, overseeing a diverse portfolio including pressure and level transmitters, temperature sensors, and fluid property measurement solutions. Based in Lawrenceville, Georgia, Chad brings deep expertise in OEM and process industries, having previously led regional sales efforts across the Midwest and Northeast for mobile machinery and chemical\/O&amp;G sectors. Prior to joining WIKA, Chad held key roles driving business development and regional growth. A graduate of PennWest California with a master\u2019s degree, Chad has also completed executive training in product strategy at Kellogg and negotiation coursework through Dale Carnegie. Known for a strong command of technical sales, negotiation, and cross-functional collaboration, Chad continues to deliver value through strategic product leadership and customer-focused innovation.\",\"url\":\"https:\/\/blog.wika.com\/us\/author\/creinhard\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Pt100 RTDs for High-Vibration Applications in Power Plants, Refineries","description":"Vibrations can damage RTDs and thermocouples, and lead to incorrect temperature measurements, short circuits, and sensor failure. WIKA USA\u2019s Pt100 sensors minimize these risks, keeping costs and downtime under control in power plants, refineries, cement plants, steel mills and petrochemical plants.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/","og_locale":"en_US","og_type":"article","og_title":"Pt100 RTDs for High-Vibration Applications in Power Plants, Refineries","og_description":"Vibrations can damage RTDs and thermocouples, and lead to incorrect temperature measurements, short circuits, and sensor failure. WIKA USA\u2019s Pt100 sensors minimize these risks, keeping costs and downtime under control in power plants, refineries, cement plants, steel mills and petrochemical plants.","og_url":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/","og_site_name":"WIKA blog","og_image":[{"width":838,"height":471,"url":"https:\/\/blog.wika.com\/us\/files\/2018\/08\/high-vibration-temp-measurement_copyright-shutterstock_resized.jpg","type":"image\/jpeg"}],"author":"Chad Reinhard","twitter_misc":{"Written by":"Chad Reinhard","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/#article","isPartOf":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/"},"author":{"name":"Chad Reinhard","@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/5459487bc00f1a51b7793a0ae24a8395"},"headline":"For High-Vibration Applications, Use Rugged Pt100 Sensors","datePublished":"2018-08-02T02:27:02+00:00","dateModified":"2025-11-12T15:57:44+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/"},"wordCount":505,"image":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/us\/files\/2018\/08\/high-vibration-temp-measurement_copyright-shutterstock_resized.jpg","keywords":["power generation","refinery","RTD","temperature measurement","temperature sensor","vibration"],"articleSection":["Temperature"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/","url":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/","name":"Pt100 RTDs for High-Vibration Applications in Power Plants, Refineries","isPartOf":{"@id":"https:\/\/blog.wika.com\/us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/#primaryimage"},"image":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.wika.com\/us\/files\/2018\/08\/high-vibration-temp-measurement_copyright-shutterstock_resized.jpg","datePublished":"2018-08-02T02:27:02+00:00","dateModified":"2025-11-12T15:57:44+00:00","author":{"@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/5459487bc00f1a51b7793a0ae24a8395"},"description":"Vibrations can damage RTDs and thermocouples, and lead to incorrect temperature measurements, short circuits, and sensor failure. WIKA USA\u2019s Pt100 sensors minimize these risks, keeping costs and downtime under control in power plants, refineries, cement plants, steel mills and petrochemical plants.","breadcrumb":{"@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/#primaryimage","url":"https:\/\/blog.wika.com\/us\/files\/2018\/08\/high-vibration-temp-measurement_copyright-shutterstock_resized.jpg","contentUrl":"https:\/\/blog.wika.com\/us\/files\/2018\/08\/high-vibration-temp-measurement_copyright-shutterstock_resized.jpg","width":838,"height":471,"caption":"Vibrations can damage RTDs and thermocouples, and lead to incorrect temperature measurements, short circuits, and sensor failure. WIKA USA\u2019s rugged Pt100 sensors minimize these risks."},{"@type":"BreadcrumbList","@id":"https:\/\/blog.wika.com\/us\/products\/temperature-products\/pt100-sensors-high-vibration\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.wika.com\/us\/"},{"@type":"ListItem","position":2,"name":"For High-Vibration Applications, Use Rugged Pt100 Sensors"}]},{"@type":"WebSite","@id":"https:\/\/blog.wika.com\/us\/#website","url":"https:\/\/blog.wika.com\/us\/","name":"WIKA blog","description":"Our blog offers many interesting articles on pressure, temperature, level, flow measurement calibration technology and provides insights into the WIKA Group.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.wika.com\/us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/blog.wika.com\/us\/#\/schema\/person\/5459487bc00f1a51b7793a0ae24a8395","name":"Chad Reinhard","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.wika.com\/us\/files\/2025\/11\/wikajune2022_chad-reinhard_blog-120x120.jpg","url":"https:\/\/blog.wika.com\/us\/files\/2025\/11\/wikajune2022_chad-reinhard_blog-120x120.jpg","contentUrl":"https:\/\/blog.wika.com\/us\/files\/2025\/11\/wikajune2022_chad-reinhard_blog-120x120.jpg","caption":"Chad Reinhard"},"description":"With over a decade of experience in industrial instrumentation and sales leadership, Chad currently serves as Senior Product Manager at WIKA Group, overseeing a diverse portfolio including pressure and level transmitters, temperature sensors, and fluid property measurement solutions. Based in Lawrenceville, Georgia, Chad brings deep expertise in OEM and process industries, having previously led regional sales efforts across the Midwest and Northeast for mobile machinery and chemical\/O&amp;G sectors. Prior to joining WIKA, Chad held key roles driving business development and regional growth. A graduate of PennWest California with a master\u2019s degree, Chad has also completed executive training in product strategy at Kellogg and negotiation coursework through Dale Carnegie. Known for a strong command of technical sales, negotiation, and cross-functional collaboration, Chad continues to deliver value through strategic product leadership and customer-focused innovation.","url":"https:\/\/blog.wika.com\/us\/author\/creinhard\/"}]}},"_links":{"self":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/9873","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/users\/429"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/comments?post=9873"}],"version-history":[{"count":10,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/9873\/revisions"}],"predecessor-version":[{"id":16180,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/posts\/9873\/revisions\/16180"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/media\/9878"}],"wp:attachment":[{"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/media?parent=9873"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/categories?post=9873"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.wika.com\/us\/wp-json\/wp\/v2\/tags?post=9873"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}